Pioneer CT-70R Service Manual page 36

Stereo cassette tape deck
Table of Contents

Advertisement

Available languages

Available languages

-——————
7. Recording Level Adjustment
|
a
a
Mode
Input signal & test tape
Adjustment location
Iuheeniving location
Adjustment value
Remarks
1
1
Recording
Apply 315Hz/-10dBv (316
INPUT level control
|
-7.7dBv
INPUT level control position
Pause
mV) to LINE INPUT
{412.mV)
setting
terminals.
Recording
Record the signal on the
VR307 (left ch.)
~7.7dBv
/playback
STD-608A test tape, and
VR308 {right ch.}
(412.1mV)
then play that section
(playback level)
of the tape.
TP.1 (left ch.)
TP.2 (right ch.)
3
Recording
Record the signal on the
VR309 (left ch.)
(Dolby NR assy}
-7.7dBv
Repeat
the
recording
and
/playback
STOD-603 test tape, and
VR310 (right ch.)
(412.1mV)
playback, and adjust accord-
then play that section
(playback level)
ingly.
of the tape.
———
4
Recording
Record the signal on the
VR311
(left ch.)
~7.7dBv
/playback
STD-604 test tape, and
VR312 (right ch.)
(412.1mV)
then play that section
(playback level)
of the tape.
1
5
VR307, VR309, and VR311
{left channel) and VR308, VR310, and VR312 (right channel) are to be adjusted in the specified adjustment order. If any
single control is adjusted separately, always check {and adjust) the other controls which follow it in the adjustment procedure order.
8. Level Meter OdB Check
| |
Moe
| Input signal & test tape
Adjustment location
| Measuring location
Rated specifications
Recording
Apply 315Hz/-10dBv
INPUT level controt
{TP.1 (left ch.)
Check
that
the
level
is -7.7dBv+2dB
when
the
pause
(316mV) to LINE INPUT
TP.2 (right ch.)
"'OdB'"' display segment lights up.
terminals.
{Dolby NR ass'y)
9. Leader Tape Detector Level Adjustment
S|
Mode
| input signal & test tape
Adjustment location
[Measuring location [Adjustment value
Remarks
1
Disconnect the CN304 connector.
Stop
Apply a 2kHz/-17dBv
VR319
Pin 4 of 1C303
DC10.5V+0.25V
(0.4Vp-p) signal to the
(PA3010)
TP (PH TR OUT) terminals.
Reconnect the CN 304 connector.
Playback
Load a cassette half which
is without any tape
The position marked
| TP. (PH TR OUT)
"A" in Fig. 10-19
If the
waveform
(square
wave)
at the
measured
location is greater than 0.6Vp-p, connect the section
indicated by "A" in Fig. 10-19.
Fig. 10-19
Adjustment location (on foil side of Mother assembly)