Advertisement

4. VU Meter
Test Setup:
Calibration
REC, LINE Amp
100 kQ.
z
LINE
OUT jack
VU meter
MIC jack
R334, R434
Switch Setting:
MONITOR switch
SOURCE
Specification:
0 +0.5 on the VU meter scale when the line
output is 0 dB (0.775 V).
Playback
Test Setup:
Head
Azimuth and
VTVM
Angle
:
PB Amp
Adjustment
:
100 kQ
=
E OUT
jack
J-19-A2
LIN
faci
Switch Setting:
MONITOR
switch
Specification:
Screw position where
the maximum
output is
obtained.
Notes:
(1)
Before the adjustment, make
sure that the
head comes in contact with the tape noxmal-
ly in forward mode.
— 28 —
(2)
Procedures
Deliver a 1 kHz signal of -60 dB (0.775 mV) to
the MIC jack.
Place the unit in the stereo-record mode.
Adjust the MIC volume control for 0 dB (0.775 V)
on the VTVM.
Adjust R334 and R434 so that the pointer of VU
meter stays at 0 + 0.5 VU on the meter.
When
changing
the frequency
from
1 kHz
to
100 Hz and 10 kHz, make sure that the VU meter
reads between -1 and +1 on the meter.
'U meter
Play back
the SONY
alignment
tape J-19-A2
(12.5 kHz).
Adjust the playback head azimuth adjusting screw
for the maximum output on the VTVM.
Note: If the maximum value for both channels can
not be obtained
at the same
angle of the
screw, take the mid between the two angles
and make sure that the defference between
the output
obtained
by turning the screw
from the maximum
output position and the
each
maximum
output
is within
0.5 dB.
Loosen the playback head angle adjusting screws.
Slightly, hold the supply reel table by the hand.
Adjust
by
moving
the
playback
head
in the
direction shown by the arrows (See Fig. 3-26) so
that the level fluctuation is the least at the maxi-
mum
output and the playback output does not
increase more than 0.5 dB.
Repeat the above steps (1) and (2).
Apply
lock
paint
to
the
azimuth
and
angle
adjusting screws.
within 0.5 dB
acid
.
screw angle
adjusting point