Checks After Mechanical Adjustment
a)
Torque Check
FWD, REV torque
... more than 200g. cm
(2.78 oz. inch)
FF, REW torque.....
more than 100 g. cm
(1.39 oz. inch)
FWD, REV back tension
eke ote a thes 200 — 240g. cm*
(2.78—3.32 oz. inch)
FF, REW back tension
(0.83—1.1 oz. inch)
* : adjustable
After making
adjustments,
clean the following
parts with a soft cloth dampened with denatured
alcohol;
head
core,
tape
guide, pinch roller,
scrape filter roller, brake
contact
part of the
reel table.
Tape
Contact
Check
of Scrape
Filter
Roller
Thread a 7-inch tape along the tape path and set
the tape speed switch to the 4.8 cm/s position.
b) Run the tape. Make
sure that the scrape filter
roller
is rotating.
Stop the roller by fingers.
Make sure that the roller starts rotating again
when
taking
off the
fingers from
the roller.
If necessary,
adjust the position of the scrape
filter roller by loosening the screw.
Wow and Flutter Measurement
Make
measurements
at the beginning and the
end of the tape. The measurement may be done
with
the
unit
set to either
FWD
and
REV
mode.
—~24—
*At 19 cm/s (7-1/2 ips) and 9.5 cm/s (3-3/4 ips)
tape speed
Steps
(1)
Connect
a wow
meter
and a 100-kQ resistor in
parallel with the LINE
OUT jack.
(2)
Set the MONITOR
switch to TAPE.
(3)
Play back the alignment tape indicated below.
(4)
Make
sure that the satisfied
result is obtained
on the wow
meter.
19 cm/s
Play back SONY
(7-% ips)
alignment tape
WS-19-7
less than
0.12 %
(RMS)
Play back SONY
alignment tape
WS-9-7
less than
0.15 %
(RMS)
9.5 cm/s
(3-% ips)
*At 4.8 cm/s (1-'/8 ips) tape speed
Steps
(1)
Set the record volume controls to the position
specified in Precaution (8) on page 25.
(2)
Connect a wow
meter and a 100-kQ resistor in
parallel with the LINE
OUT jack.
(3)
Set the MONITOR switch to TAPE.
(4)
Deliver a 3-kHz signal of -60 dB (-10 dB) to the
MIC
(AUX) jack.
(5)
Record
the
signal on
the blank
tape.
(6)
Make
sure that the satisfied result is obtained
on the wow
meter.
Specification
less than 0.40 % (RMS)