  • Page 1 ○ MODEL GSN65-D GAS CONCRETE NAILER SAFETY OPERATE MANUAL...
  • Page 2: Table Of Contents

    CONTENTS ITEM PAGE ............ SAFETY ........2. SPECIFICATION .... 3. GENERAL OPERATION MANUAL .......... 4. MAINTENANCE 5. EXPLODED DRAWING AND PARTS LIST...
  • Page 3: Safety

    NOTE emphasizes essential information. gases that may flammable materials. The p us h le ve r an d no se will EXPLANATION OF THE FUNCTION OF THE TOUA become hot and get heated up after NAILER prolonged or rapid use.
  • Page 4 Keep the Nailer, fuel cells and battery 9. STORE NAILER PROPERLY WITH FUEL CELL aw ay f r om s uns hi ne and from 120°F MAX AND BATTERY REMOVED. (50℃) t em per at ur e ex c eeding 120°F When not in use, the Nailer, fuel cell and battery (50°C).
  • Page 5 TOUA authorized service center. repair the Nailer. 30. NEVER MODIFY OR ALTER A NAILER. 23. TAKE FUEL CELL AND BATTERY OUT OF...
  • Page 6 2. Before using battery charger, read all instructions and cautionary markings on (1)nailer,(2) battery charger, (3) battery. 3. To reduce risk of injury, only use TOUA rechargeable WARNING battery type 504.4.04.011.01 . Other type of batteries may burst causing personal injury and  ...
  • Page 7 EMPLOYER'S RESPONSIBILITIES R E M E MBER : ONLY US E TOUA B ATTERY 1. Ensure that this MANUAL is available to operators TYPE 504.4.04.011.01. and personnel performing maintenance. OTHER TYPES OF BATTERIES MAY BURST 2.
  • Page 8: Specification

    SPECIFICATION 1 . GAS CONCRETE NAILER TYPE GSN65-D Type of power Piston reciprocating Applicable nails See 2. Available Nails. Nail Capacity 1 nails Ambient temperature -5 ℃~ 50 ℃ (23 ℉ to 120 ℉ ) Dimensions 19.30 "(L)×14.75"(H)×4.80"(W) 490mm (L)×375mm (H)×122mm (W)...
  • Page 9: General Operation Manual

    The information contained in this Manual is designed to assist you in the safe operation of the Nailer. Some illustrations in this Manual may show details or attachments that differ from those on your own Nailer. NAME OF PARTS 1. Gas Heat Preservation Nail ( MODEL: GSN65-D ) Latch Top Cover Cell Cover...
  • Page 10 ■ TOUA charger(504.4.04.013.01) only use for 7.Case ······························································· TOUA battery (504.4.04.011.01), and TOUA battery( 504.4.04.011.01 ) also only use for OPTIONAL ACCESSORIES TOUA charger( 504.4.04.013.01 ), if not, may sold separately cause the charger damage or battery burst. 1.Fuel Cell 2.Cleaner (Code No.
  • Page 11 Take When the green pilot lamp does not light on it to your TOUA authorized Service Center. even if more than three hours has passed after start of the charging, stop the charging...
  • Page 12 Nailer by using the checklist below. Conduct the Fuel Cell tests in the following order. If abnormal operation occurs, stop using Nailer and contact a TOUA authorized service center immediately. (1) REMOVE FUEL CELL AND BATTERY (1) Separate the metering valve and the cap from FROM NAILER.
  • Page 13 ■ In push gun mouth down, tapping and pull the trigger (3) INSERT FUEL CELL INTO NAILER. necessary action is smooth Pulling the latch and open the cell cover. ① Latch Cell Cover Trigger Insert the fuel cell into nailer. ②...
  • Page 14 ■ Do not touch around the exhaust Leave the trigger finger, against the workpiece against outlet with bare hands. gun mouth, press the nail gun, fan start at this time The push lever and nose will become hot and get heated up after prolonged or rapid use.
  • Page 15 HEAT PRESERVATION NAIL REAL PLAY downward nailer 2~3 times, pulling the trigger , the nails will be driven. Or use after put the nailer and fuel cell indoor 30 minutes. Insert the nail insulation components heat preservation nail gun,until the end . This Nailer is equipped with a FULL SEQUENTIAL ACTUATION MECHANISM.
  • Page 16 MUSING THE HOOK CAUTION Using the hook, can hang on the nailer to the work belt or scaffolding on work. This nailer hook can left and right side by side mounting , as (a) and (b). If need, can according to the following steps exchange : (1) Use accessory wrench (M5) loosen and pull out two screws;...
  • Page 17: Maintenance

    ② Clean the magazine. Remove paper chips or wooden chips which may have accumulated in the magazine. ③ Lubricate it with TOUA designated lubricant oil. WARNING Remove fuel cell, battery and all nails from Nailer when: Daily cleaning; Maintenance and Inspection;...
  • Page 18 ■ Keep it out of reach of children. 4. WARNING LABEL Change the WARNING LABEL if missing or damaged. A new WARNING LABEL is available from a TOUA authorized service center. 5. Maintenance chart ACTION...
  • Page 19 Note the color of the light indicator. If red: charge the battery. when push lever is pressed. If green: Contact TOUA for replacement. Inspect if the battery temperature within Wait the battery temperature as Unable to charge battery require range 50°F( 10°C) ~ 104°F (40°C).
  • Page 20: Exploded Drawing And Parts List

    EXPLODED DRAWING AND PARTS LIST GAS CONCRETE NAILER MODEL: GSN65D 501-1 501-2 Notes: Torque (Nm) Ltem Remark 17    Loctitle 277    1 ~ 1.2     71    84    91    1.8 ~ 2     5    38    74   ...
  • Page 21 PART LIST GSN65D Note : consumable parts Parts Name Parts Name Right Handle Hex Bolt M5×10 Rotating shaft Top Cover Lock block Filter Trigger Filter Cover Trigger spring Cross Recessed Bolt M4×10 Retaining Ring d0=24 Fuel cell sponge Gasket Screw ST2.2×11 Rubber Gasket Switch spring Washer...
  • Page 24 Nanjing Toua Hardware&Tools Co.,Ltd. #129 Linqi Road Dongshan Industrial Concentraion Zone of Jiangning,Nanjing,China Postal Code: 211103 Tel:0086-25-52174012,52174008,52174016,52174019 Email:nails@tengya-nj.com;nails@jsmail.com.cn Website:www.tengya.com...