Kenwood NX-220 K Service Manual page 45

Vhf digital transceiver
Table of Contents

Advertisement

Transmitter Section
Item
Panel tuning mode
1. High
1) Adj item: [HPWR]
power
Adjust: [✳✳✳✳.]
(Batt: 7.5V)
2) Adj item: [H.PWR_]→
[H.P.WR_]→[H.P.W.R_]→
[H.P.W.R._]→[H.P.W.R._.]
Adjust: [✳✳✳✳.]
PTT: ON
Press [B] key to
store the adjust-
ment value.
2. Low
1) Adj item: [LPWR]
power
Adjust: [✳✳✳✳.]
(Batt: 7.5V)
2) Adj item: [L.PWR_]→
[L.P.WR_]→[L.P.W.R_]→
[L.P.W.R._]→[L.P.W.R._.]
Adjust: [✳✳✳✳.]
PTT: ON
Press [B] key to
store the adjust-
ment value.
3. Balance *2 1) Adj item: [BAL]
Adjust: [✳✳✳✳.]
Deviation meter
LPF: 3kHz
HPF: OFF
2) Adj item: [B.AL_ _]→
[B.A.L_ _]→[B.A.L._ _]→
[B.A.L._._]→[B.A.L._._.]
Adjust: [✳✳✳✳.]
PTT: ON
Press [B] key to
store the adjust-
ment value.
[Side1] key: Press
while transmitting
to change 20Hz and
2kHz.
20Hz: "–" not appears
2kHz: "–" appears
*2: Refer to the "Necessary Deviation adjustment item for each signaling and mode" table on page 50.
Balance adjustment is common with the adjustment of all signaling deviations.
4. Maximum
1) Adj item: [NDEV]
Deviation
Adjust: [✳✳✳✳.]
(NXDN) *3
Deviation meter
LPF: 3kHz
[Narrow]
HPF: OFF
2) Adj item: [N.DEV_]→
[N.D.EV_]→[N.D.E.V_]→
[N.D.E.V._]→[N.D.E.V._.]
Adjust: [✳✳✳✳.]
PTT: ON
Press [B] key to
store the adjust-
ment value.
ADJUSTMENT (K TYPE)
Condition
PC test mode
equipment
1) Adj item: [High
Power meter
Transmit Power]
Ammeter
2) Adj item: [Low],
[Low'], [Center],
[High'], [High]
PTT: Press
[Transmit] button.
Press [Apply All]
button to store the
adjustment value.
1) Adj item: [Low
Transmit Power]
2) Adj item: [Low],
[Low'], [Center],
[High'], [High]
PTT: Press
[Transmit] button.
Press [Apply All]
button to store the
adjustment value.
1) Adj item: [Balance]
Deviation
Deviation meter
meter
LPF: 3kHz
Oscilloscope
HPF: OFF
2) Adj item: [Low],
[Low'], [Center],
[High'], [High]
PTT: Press
[Transmit] button.
Press [Apply All]
button to store the
adjustment value.
[2kHz Sine Wave
Check box]: Check
while transmitting
change to 2kHz.
1) Adj item: [Maximum
Deviation
Deviation (NXDN
meter
Narrow)]
Oscilloscope
Deviation meter
LPF: 3kHz
HPF: OFF
2) Adj item: [Low],
[Low'], [Center],
[High'], [High]
PTT: Press
[Transmit] button.
Press [Apply All]
button to store the
adjustment value.
Measurement
Test-
Unit Terminal Unit
Panel
ANT
Panel
Panel
ANT
Panel
Panel
ANT
Panel
NX-220
Adjustment
Specifi cations /
Parts
Method
[Panel
5.0W
±0.1W
tuning
2.1A or less
mode]
Selector
[PC test mode]
Press [Apply All]
[PC test
button to store the
mode]
adjustment value
[ ],[ ]
after all adjustment
points have been
adjusted.
1.0W
±0.05W
1.1A or less
[PC test mode]
Press [Apply All]
button to store the
adjustment value
after all adjustment
points have been
adjusted.
[Panel
The Deviation of
2kHz Tone deviation
tuning
20Hz frequency is
is within ±1.0% of
mode]
fi xed. Change the
20Hz tone devia-
Selector
2kHz adjustment
tion.
value to become
[PC test
the same deviation
[PC test mode]
mode]
of 20Hz within the
Press [Apply All]
[ ],[ ]
specifi ed range.
button to store the
adjustment value
after all adjustment
points have been
adjusted.
[Panel
3056Hz
2995~3117Hz
tuning
Write the value as
mode]
followings.
[PC test mode]
Selector
513 (Reference
Press [Apply All]
value)
button to store the
[PC test
adjustment value
mode]
after all adjustment
[ ],[ ]
points have been
adjusted.
Remarks
45