Installation and use of this device must be done by qualified, authorized and trained technical personnel only.
Inspect device carefully before installation. Do not install and use broken and defective devices.
Do not disassemble device. Do not make any repair on any part of the device. There is no accessible part inside the
device. Please contact to manufacturer for broken and defective devices.
Do not use device in environments subject to flammable, explosive and corrosive gases and/or substances.
This device is designed for applications only in light industrial environments. This device is not suitable for medical
and residential use. This device is not suitable for use related with human health and safety. This device is not suita-
ble for automotive, military and marine use.
Do not allow children and unauthorized people to use this device.
Before installation and any technical work, disconnect the power supply and mains connections.
Check the power supply voltage level before power on, and make sure voltage level is in specified limits.
Check quality of neutral line. Improper neutral line may give permanent damage to the device.
Connect an external power switch and an external fuse (1A, 250VAC) to the power supply line that are easily acces-
sible for rapid intervention. Connect an external fuse (2A, 250VAC) for each relay output separately.
Use appropriate cables for power supply and mains connections. Apply safety regulations during installation.
Install the device in a well ventilated place. Install the device permanently into a proper panel cut-out. Fix the device
with two fasteners supplied with the device. Only front panel must be accessible after installation is completed.
Do not operate the device other then the environmental conditions given in Technical Specification.
Take precautions against negative environmental conditions like humidity, vibration, pollution and high/low tempera-
ture during installation.
USER MANUAL
GENERAL SPECIFICATION

WARNINGS

DOWNLOAD
SXT48R

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SYROS Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Ditel SYROS Series

  • Page 1 SXT48R QUICK INSTALLATION GUIDE DOWNLOAD USER MANUAL AUTO-TUNE PID TEMPERATURE CONTROLLER WITH CONTROL RELAY + ALARM GENERAL SPECIFICATION WARNINGS Installation and use of this device must be done by qualified, authorized and trained technical personnel only. Inspect device carefully before installation. Do not install and use broken and defective devices. Do not disassemble device.
  • Page 2 WIRING WARNING: if 2 wire Pt100 is used, connect compensation lead to measuring lead: (SXT48R: 10-11) SXT48R MFR’D 06 21 Use correct compensation cables for T/C sensors. 000000000000 Connect T/C cable directly to the device connectors. Keep device, signal cables and communication cables away from circuit breakers, power cables and devices/cables emitting electrical noise.
  • Page 3 PROGRAMMING PARAMETERS (1)When sensor type is changed, Up.L, Lo.L, H.Set, A.Set, H.hys, Error Messages: A.hys, r.Alr, b.Alr, oFFs may be set to a new value automatically, Fail: Sensor failure or sensor selection wrong according to the selected sensor. E.FLS: Hardware failure (2)ON-OFF control is the only option for Cooling function E.CAL: Hardware failure DOWN UP BACK SET...
  • Page 4 Use only a dry and clean non-abrasive cloth. Before cleaning, disconnect the power supply and mains connections. Tel. +34 933 394 758 DISEÑOS Y TECNOLOGÍA, S.A. Fax +34 934 903 145 Xarol, 6B P.I. Les Guixeres 08915 Badalona (Barcelona) - Spain Email: comercial@ditel.es ; web: www.ditel.es 20230621 30727801...

This manual is also suitable for:

Sxt48rSxt48

Table of Contents