Trouble shooting
CAUTION: Disconnect the power supply before servicing.
Status
No power
The motor
does not run
Body
vibration
Noise
vibration
Weak
suction
Light does
not work
READ AND SAVE THESE INSTRUCTIONS
Cause and Method of Repairing
Check circuit breakers
If the power supply is damaged,
please call for a qualified person
a).The motor is broken, replace motor.
b). The switch control is broken, replace switch.
c). The capacitor is broken, replace capacitor.
a).The installation is not correct, check it and
make sure the hood is level.
b). The fan is broken, replace motor assembly.
c). The fan motor was not properly installed,
check and make sure it is firmly installed.
Something dropped into the blower, check
and clean blower.
a). The distance from the range hood to cooking
surface is too far, make sure the distance
between bottom of the hood to cooking surface
is minimum 24" to maximum 27".
b). Windows, doors and drafts can effect the
performance of the range hood.
c). There are other air conditions effecting the
vent pipe, make sure lower vent pipe's exit
is in a downward direction.
d). The running rate of the motor slows down,
replace the motor or capacitor.
If the range hood is near the window,
the best solution is to protect the back of the
range hood from draft caused by a window or
door.
Replace LED lamp.
Tools required
Philips
Screwdriver
Philips
Screwdriver
Philips
Screwdriver
Philips
Screwdriver
Philips
Screwdriver
Philips
Screwdriver

Advertisement