Download Print this page

Safety Check-Out - Sony PS-LX230 Service Manual

Stereo turntable system

Advertisement

PS-LX230/LX230€/LX231
PS-LX231: VL-42G
Type
Moving magnet type
Frequency response
20 Hz to 20 kHz
Channel separation
16 dB at 1 kHz
Output voltage
2.5mVat1kHz,5cm/isec.
Load impedance
50to 100 kilohms
Tracking force
2g
Stylus
Sony ND-142G
(conical 0.6 mil diamond)
Weight
8g
General
Power requirements
US, Canadian model:
120 Vac, 60Hz
AEP model:
220 Vac, 50/60Hz (240V ac adjustable
by authorized Sony personnel)
UK model:
240V ac, 50/60 Hz (220V ac adjustable
by authorized Sony personnel)
E model:
110—120 or 220—240V ac adjustable,
50/60 Hz
Power consumption
5W
Dimensions
Approx. 430 x 110 x 360 mm (w/h/d)
(17 x 43/3 x 14 in.)
including projecting parts and controls
Weight
Approx. 3.5 kg (7 Ibs 12 02), net
MODEL
IDENTIFICATION
— Specification Label —
PS-LX230
PS-LX231
SONY:
MODEL NO.L____|
STEREO
TURNTABLE
SYSTEM
be cnnennaesingancniiienscaed
SERIAL NO.
MADE
IN JAPAN
US, Canadian model:
AC:
120V60Hz 5W
AEP model:
AC:
220V~50/60Hz 5W
UK model:
AC:
240V~50/60Hz 5W
E model:
AC:
110—120V, 220—240V~
50/60Hz 5W
SAFETY
CHECK-OUT
(US Model)
After
correcting
the
original
service
problem,
perform
the following safety check before releasing
the set to the customer:
Check the antenna terminals, metal trim, ''metallized"'
knobs, screws, and all other exposed metal parts for
AC leakage. Check leakage as described below.
LEAKAGE
TEST
The AC leakage from any exposed metal part to
earth ground and from all exposed metal parts to any
exposed
metal part having a return to chassis, must
not
exceed
0.5
mA
(S00
microampers).
Leakage
current
can
be
measured
by
any
one
of
three
methods.
1.
A
commercial
leakage
tester,
such
as
the
Simpson
229
or RCA
WT-540A.
Follow
the
manufacturers' instructions to use these instru-
ments.
2.
A battery-operated
AC milliammeter. The Data
Precision
245 digital multimeter is suitable for
this job.
3.
Measuring the voltage drop across a resistor by
means
of a VOM
or battery-operated AC volt-
meter.
The
'"'limit''
indication
is 0.75
V, so
analog
meters
must
have
an
accurate
low-
voltage
scale.
The
Simpson
250
and
Sanwa
SH-63Trd
are examples of a passive VOM
that
is suitable.
Nearly all battery operated
digital
multimeters
that
have
a
2 V
AC
range
are
suitable. (See Fig. A)
To Exposed Metal
Parts on Set
AC
vo/tmeter
(0.75 V)
=
Earth Ground
Fig. A. Using an AC voltmeter to check AC leakage.