Download Print this page
kozy heat NCK-LX22L-S30 Quick Start Manual
kozy heat NCK-LX22L-S30 Quick Start Manual

kozy heat NCK-LX22L-S30 Quick Start Manual

Natural gas conversion kit

Advertisement

Available languages

Available languages

Quick Links

NATURAL GAS CONVERSION KIT
#NCK-LX22L-S30
For use with #LXL-22-L
Direct Vent Gas Stove
___________________________________________________________________________________________________________
This fireplace is certified under U.S. and Canadian standards ANSI Z21.88-2019/CSA 2.33-2019, CSA 2.17- 2017
THE CONVERSION SHALL BE CARRIED OUT BY A
MANUFACTURER'S AUTHORIZED REPRESENTATIVE,
IN ACCORDANCE WITH THE REQUIREMENTS OF THE
MANUFACTURER, PROVINCIAL OR TERRITORIAL AU-
THORITIES HAVING JURISDICTION AND IN ACCORD-
ANCE WITH THE REQUIREMENTS OF THE CAN/CGA-
B149.1 OR CAN/CGA-B149.2 INSTALLATION CODES.
CETTE CONVERSION DE GAZ DOIT ÊTRE EFFECTUÉE
PAR UN REPRÉSENTANT AUTORISÉ DU FABRICANT,
CONFORMÉMENT AUX EXIGENCES DU FABRICANT
ET DES AUTORITÉS PROVINCIALES OU TERRITORIAL-
ES AYANT JURIDICTION, ET AUX EXIGENCES DES
CODES D'INSTALLATION CAN/CGA-B149.1 OU CAN/
CGA-B149.2.
This conversion kit shall be installed by a qualified
service agency in accordance with the manufactur-
er's instructions and all applicable codes and re-
quirements of the authority having jurisdiction. If
the information in these instructions is not fol-
lowed exactly, a fire, explosion or productions of
carbon monoxide may result, causing property
damage, personal injury, or loss of life. The quali-
fied service agency is responsible for proper instal-
lation of this kit. The installation is not proper and
complete until operation of the converted appli-
ance is checked as specified in the manufacturer's
instructions supplied with the kit. Refer to appli-
ance owner's manual or product data plate for
proper inlet and manifold pressure adjustments
and orifice sizing.
LXL-22-L
Rev. 1 - November 2023
IMPORTANT
WARNING
P.O. BOX 557 204 INDUSTRIAL PARK DRIVE
LAKEFIELD, MINNESOTA USA 56150-0577
READ ALL STEPS BEFORE STARTING INSTALLATION.
LEAVE THESE INSTRUCTIONS WITH THE APPLIANCE.
This gas conversion kit installation instructions must be
used in conjunction with the installation and operation
manual provided with the appliance. Please read the ap-
pliance owner's manual completely before performing any
procedures in these instructions. All warnings, precau-
tions, and instructions outlined in the manual provided
with the appliance will continue to apply to these instruc-
tions.
ATTENTION
Ce kit de conversion doit être installé par une
agence de service qualifiée conformément aux in-
structions du fabricant et à tous les codes et exi-
gences applicables de l'autorité compétente. Si les
informations contenues dans ces instructions ne
sont pas suivies à la lettre, un incendie, une explo-
sion ou des productions de monoxyde de carbone
peuvent en résulter, causant des dommages maté-
riels, des blessures corporelles ou la mort. L'agence
de service qualifiée est responsable de l'installa-
tion correcte de ce kit. L'installation n'est pas cor-
recte et complète jusqu'à ce que le fonctionne-
ment de l'appareil converti soit vérifié comme
spécifié dans les instructions du fabricant fournies
avec le kit. Reportez-vous au manuel du proprié-
taire de l'appareil ou à la plaque signalétique du
produit pour les réglages de pression d'admission
et d'admission appropriés et le dimensionnement
de l'orifice.
1
PFS Report Number: 21-739
Starting serial #23 01501 51

Advertisement

loading
Need help?

Need help?

Do you have a question about the NCK-LX22L-S30 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for kozy heat NCK-LX22L-S30

  • Page 1 NATURAL GAS CONVERSION KIT #NCK-LX22L-S30 For use with #LXL-22-L Direct Vent Gas Stove P.O. BOX 557 204 INDUSTRIAL PARK DRIVE LAKEFIELD, MINNESOTA USA 56150-0577 ___________________________________________________________________________________________________________ This fireplace is certified under U.S. and Canadian standards ANSI Z21.88-2019/CSA 2.33-2019, CSA 2.17- 2017...
  • Page 2 LXL-22-L PFS Report Number: 21-739 Rev. 1 - November 2023 Starting serial #23 01501 51...
  • Page 3: Prepare The Fireplace

    Conversion Kit Components C. Convert Pilot Assembly • (1) Gas Conversion Label 1. Remove the spring holding the pilot hood in place. Then pull the pilot hood directly up from the pilot bracket. • (1) 30% Turndown Stepper Motor* 2. Insert a 5/32” (4 mm) hex key into the injector’s hexagon •...
  • Page 4: Complete The Conversion

    D. Complete the Conversion 1. Reinstall burner assembly. Position the burner tube over the burner orifice while aligning the flange on the sliding venturi shutter with the slots on adjustable venturi mount. Align the holes in the burner assembly with the holes in the firebox floor. 2.
  • Page 5 Figure 4, Burner Venturi Adjustment Figure 5, Burner Venturi Adjustment LXL-22-L PFS Report Number: 21-739 Rev. 1 - November 2023 Starting serial #23 01501 51...
  • Page 6: Verify Operation

    E. Test Inlet Pressure Table 4, Manifold Gas Supply Pressures IMPORTANT: For a proper pressure reading, apply the gas supply pressure tests with all other gas appliances on or at Fuel High full capacity in the household. Natural Gas 1.6” WC (0.41 kPa) 3.5” WC (0.87kPa) 1.
  • Page 7 Composants du kit de conversion • (1) Étiquette de conversion de gaz • (1) Moteur pas à pas à 30% de reduction* • (1) Étiquette de gaz • (1) Pilote Injecteur Gaz naturel #62 • (1) Orifices du brûleur : #3.20mm * Le moteur pas à...
  • Page 8 D. Terminez la conversion 1. Réinstallez l’ensemble du brûleur. Positionnez le tube du brûleur sur l'orifice du brûleur tout en alignant la bride du volet ven- turi coulissant avec les fentes du support venturi réglable. Alignez les trous de l’assemblage du brûleur avec les trous du plancher de la chambre de combustion.
  • Page 9 Figure 4, Réglage du venturi du brûleur Figure 5, Réglage du venturi du brûleur LXL-22-L PFS Report Number: 21-739 Rev. 1 - November 2023 Starting serial #23 01501 51...
  • Page 10 E. Tester la pression d'entrée Tableau 4, pressions d'alimentation en gaz du collecteur IMPORTANT : Pour une bonne lecture de la pression, appliquez Combustible High les tests de pression d'alimentation en gaz avec tous les autres appareils à gaz allumés ou à pleine capacité dans la maison. Gaz naturel 6.4”...