4.2 Drainage Installation
Install the included drain hose to the draining nozzle on the machine and
direct the hose to the desired area before operate the machine.
If the drain area is located above the dehumidifier, the maximum capacity of
the water pump is 16.4ft. If the water is drained downwards, there is no limit
for the distance.
Press and hold DRAIN button to drain the water manually. The water pump
will work for 35 seconds before stopping. Repeat until all water is drained.
Drain the water manually before storing or moving the unit.
WARNING: Do not block the drainage hose. The end of the drainage pipe should
not be higher than the outlet hole. If the drainage pipe end is higher than the
outlet hole, water will not
unit.
drain properly and could damage components of the