Advertisement

Quick Links

AM5D4ID-2T/BCM
AM5D4ID-2L+/BCM
User Manual
Version 1.0
Published June 2023
Copyright©2023 ASRock Rack INC. All rights reserved.

Advertisement

Table of Contents
loading

Summary of Contents for ASROCK AM5D4ID-2I/BCM

  • Page 1 AM5D4ID-2T/BCM AM5D4ID-2L+/BCM User Manual Version 1.0 Published June 2023 Copyright©2023 ASRock Rack INC. All rights reserved.
  • Page 2 (including damages for loss of profits, loss of business, loss of data, interruption of business and the like), even if ASRock Rack has been advised of the possibility of such damages arising from any defect or error in the documentation or product.
  • Page 3 ASRock Rack follows the green design concept to design and manufacture our products, and makes sure that each stage of the product life cycle of ASRock Rack product is in line with global environmental regulations. In addition, ASRock Rack disclose the relevant in- formation based on regulation requirements.
  • Page 4: Table Of Contents

    Contents Chapter 1 Introduction Package Contents Specifications Unique Features Motherboard Layout Onboard LED Indicators I/O Panel Block Diagram Chapter 2 Installation Screw Holes Pre-installation Precautions Installing the CPU Installing the CPU Fan and Heatsink Installing Memory Modules (DIMM) Expansion Slot (PCI Express Slot) Jumper Setup Onboard Headers and Connectors ATX PSU / DC-IN Power Connections...
  • Page 5 3.1.2 Navigation Keys Main Screen Advanced Screen 3.3.1 CPU Configuration 3.3.2 Chipset Configuration 3.3.3 NVMe Configuration 3.3.4 ACPI Configuration 3.3.5 USB Configuration 3.3.6 Super IO Configuration 3.3.7 Serial Port Console Redirection 3.3.8 H/W Monitor 3.3.9 PCI Subsystem Settings 3.3.10 AMD CBS 3.3.11 Network Stack Configuration 3.3.12 Driver Health 3.3.13 Tls Auth Configuration...
  • Page 6 3.5.1 BMC Network Configuration 3.5.2 System Event Log 3.5.3 BMC Tools Boot Screen 3.6.1 CSM Parameters Exit Screen Chapter 4 Software Support Download and Install Operating System Download and Install Software Drivers Contact Information Chapter 5 Troubleshooting Troubleshooting Procedures Technical Support Procedures Returning Merchandise for Service...
  • Page 7: Chapter 1 Introduction

    In case any modifications of this manual occur, the updated version will be available on ASRock Rack website without further notice. Find the latest memory and CPU support lists on ASRock Rack website as well. ASRock Rack’s Website: www.ASRockRack.com About this motherboard technical support, please visit the website for specific information http://www.asrockrack.com/support/...
  • Page 8: Specifications

    1.2 Specifications AM5D4ID-2T/BCM / AM5D4ID-2L+/BCM Physical Status Form Factor Deep mini-ITX Dimension 6.7" x 8.2" (170 mm x 208mm) Processor System Supports AMD Raphael Processors Socket 1 Socket AM5 (LGA1718) Thermal Design 120W (Air) / 170W (Liquid) Power (TDP) Chipset KNOLL3 X300 System Memory Supported DIMM...
  • Page 9 AM5D4ID-2T/BCM AM5D4ID-2L+/BCM Rear I/O 1 DB15 (VGA), 1 HDMI 2 Type-A (USB3.2 Gen1) AM5D4ID-2T/BCM: RJ45 2 RJ45(10GbE), 1 dedicated IPMI AM5D4ID-2L+/BCM: 2 RJ45(1GbE), 1 dedicated IPMI Hardware Monitor Temperature CPU, DDR, MB, Card Side Fan Tachometer, Multi-Speed Control, CPU Quiet Fan (Allow Chassis Fan Speed Auto-Adjust by CPU Temperature) Voltage 3VSB, 5VSB, VCPU, VCCM, APU VDDP, 1.05V_PROM_S5,...
  • Page 10 Fan Fail LED BMC Hearbeat Support OS Microsoft® Windows®: - Windows 10 (64 bit) - Windows 11 (64 bit) Linux®: - UBuntu 22.04.2 (64 bit) * On the Windows system, Raid mode supports UEFI Boot only. * The Linux system doesn’t support Raid Mode. * Please refer to our website for the latest OS support list.
  • Page 11: Unique Features

    AM5D4ID-2T/BCM AM5D4ID-2L+/BCM 1.3 Unique Features ASRock Rack Instant Flash is a BIOS flash utility embedded in Flash ROM. This convenient BIOS update tool allows updating system BIOS without entering operating systems first like ® MS-DOS or Windows . With this utility, press the <F6> key during the POST or the <F2> key to enter into the BIOS setup menu to access ASRock Rack Instant Flash.
  • Page 12: Motherboard Layout

    1.4 Motherboard Layout 20.8 cm (8.2 in) Broadcom 57416 NCSI1 PSU_SMB1 BATTERY1 FAN1 FAN2 ATX4PIN1 ATX12V2 ATX12V1 SATA_PWR1 CLRCMOS1 DDR5_B1 DDR5_B2 DDR5_A1 DDR5_A2 AM5D4ID-2T/BCM AM5D4ID-2L+/BCM LAN1 LAN2 OCU1 HDMI1 ASPEED AST2600 CPU1 USB3.2 Gen1 IPMI_LAN TPM_BIOS_PH1 T:USB3_2 B:USB3_1 TPM1 UID1 USB3_3_4 M2_1 COM1...
  • Page 13 AM5D4ID-2T/BCM AM5D4ID-2L+/BCM Description PSU SMBus Header (PSU_SMB1) NSCI Header (NSCI1) Clear CMOS Pad (CLRCMOS1) System Fan Connector (FAN1) ATX 12V Power Connector (ATX12V1) ATX 12V Power Connector (ATX12V2) SATA Power Connector (SATA_PWR1) ATX 4-PIN Power Connector (ATX4PIN1) System Fan Connector (FAN2) 2 x 288-pin DDR5 DIMM Slots (DDR5_A1, DDR5_B1)* 2 x 288-pin DDR5 DIMM Slots (DDR5_A2, DDR5_B2)* OCuLink x4 Connector (OCU1)
  • Page 14: Onboard Led Indicators

    1.5 Onboard LED Indicators Item Status Description FAN_LED1 FAN1 failed FAN_LED2 FAN2 failed SB_PWR1 Green STB PWR ready FAN_LED3 FAN3 failed BMC_LED1 Green BMC heartbeat LED...
  • Page 15: I/O Panel

    AM5D4ID-2T/BCM AM5D4ID-2L+/BCM 1.6 I/O Panel AM5D4ID-2T/BCM No. Description No. Description 10G LAN RJ-45 Port (LAN2)** LAN RJ-45 Port (IPMI_LAN1)* 10G LAN RJ-45 Port (LAN1)** USB 3.2 Gen1 Ports (USB3_1_2) HDMI Port (HDMI1) UID Switch (UID1) VGA Port (VGA1) AM5D4ID-2L+/BCM No. Description No.
  • Page 16 IPMI LAN Port LED Indications Activity / Link LED Speed LED Status Description Status Description No Link 10Mbps connection or no link Blinking Yellow Data Activity Orange 100Mbps connection Link Green 1Gbps connection **There is an LED on each side of 10G LAN port. Please refer to the table below for the LAN port LED indications.
  • Page 17 AM5D4ID-2T/BCM AM5D4ID-2L+/BCM ***There is an LED on each side of 1G LAN port. Please refer to the table below for the LAN port LED indications. SPEED LED ACT/LIN K LED SPEED LED ACT/LIN K LED LAN Port 1G LAN Port (LAN1, LAN2) LED Indications Activity / Link LED Speed LED Status...
  • Page 18: Block Diagram

    1.7 Block Diagram AM5D4ID-2T/BCM DDR5_A1 Slot ECC/nonECC-UDIMM DDR5 CHANNEL-A DDR5_A2 Slot ECC/nonECC-UDIMM DDR5 DDR5_B1 Slot ECC/nonECC-UDIMM DDR5 CHANNEL-B DDR5_B2 Slot ECC/nonECC-UDIMM DDR5 Rear HDMI DISPLAYPORT DISPLAY 0 PCIEx16 SLOT1 PCIE GEN5 x16 PCIE 0~15 M.2_1 PCIE GEN5 x4 PCIE 16~19 AMD PROCESSOR PCIE GEN4 x1 PCIE 20...
  • Page 19 AM5D4ID-2T/BCM AM5D4ID-2L+/BCM AM5D4ID-2L+/BCM DDR5_A1 Slot ECC/nonECC-UDIMM DDR5 CHANNEL-A DDR5_A2 Slot ECC/nonECC-UDIMM DDR5 DDR5_B1 Slot ECC/nonECC-UDIMM DDR5 CHANNEL-B DDR5_B2 Slot ECC/nonECC-UDIMM DDR5 Rear HDMI DISPLAYPORT DISPLAY 0 PCIEx16 SLOT1 PCIE GEN5 x16 PCIE 0~15 M.2_1 PCIE GEN5 x4 PCIE 16~19 AMD PROCESSOR PCIE GEN4 x1 PCIE 20 Socket AM5 (LGA 1718)
  • Page 20: Chapter 2 Installation

    Chapter 2 Installation This is a deep mini-ITX form factor (6.7” x 8.2”, 17.0 cm x 20.8 cm) motherboard. Before installing the motherboard, study the configuration of the chassis to ensure that the motherboard fits into it. Make sure to unplug the power cord before installing or removing the motherboard. Failure to do so may cause physical injuries and motherboard damages.
  • Page 21: Installing The Cpu

    AM5D4ID-2T/BCM AM5D4ID-2L+/BCM 2.3 Installing the CPU 1. Before inserting the 1718-Pin CPU into the socket, please check if the PnP cap is on the socket, if the CPU surface is unclean, or if there are any bent pins in the socket. Do not force to insert the CPU into the socket if above situation is found.
  • Page 22 Carefully place the CPU in as flat as possible. Do not drop it.
  • Page 23 AM5D4ID-2T/BCM AM5D4ID-2L+/BCM Make sure the CPU is aligned with the socket before locking it into place. Make sure the black cover plate is always in place until it pops off when closing the socket lever. Please save the cover if the processor is removed. The cover must be placed if wishing to return the motherboard for after service.
  • Page 24: Installing The Cpu Fan And Heatsink

    2.4 Installing the CPU Fan and Heatsink After installing the CPU into this motherboard, it is necessary to install a larger heatsink and cooling fan to dissipate heat. It also needs to spray thermal grease between the CPU and the heatsink to improve heat dissipation.
  • Page 25 AM5D4ID-2T/BCM AM5D4ID-2L+/BCM...
  • Page 26: Installing Memory Modules (Dimm)

    2.5 Installing Memory Modules (DIMM) This motherboard provides four 288-pin DDR5 (Double Data Rate 5) DIMM slots, and supports Dual Channel Memory Technology. 1. For dual channel configuration, install identical (the same brand, speed, size and chip- type) DDR5 DIMM pairs. 2.
  • Page 27 AM5D4ID-2T/BCM AM5D4ID-2L+/BCM The DIMM only fits in one correct orientation. It will cause permanent damage to the motherboard and the DIMM if forcing the DIMM into the slot at incorrect orientation.
  • Page 28: Expansion Slot (Pci Express Slot)

    2.6 Expansion Slot (PCI Express Slot) There is 1 PCI Express slot on this motherboard. PCIE slot: PCIE7 (PCIE 5.0 x16 slot, from CPU) is used for PCI Express x16 lane width cards. Slot Generation Mechanical Electrical Source PCIE7 Installing an expansion card Step 1.
  • Page 29: Jumper Setup

    AM5D4ID-2T/BCM AM5D4ID-2L+/BCM 2.7 Jumper Setup The illustration shows how jumpers are setup. When the jumper cap is placed on the pins, the jumper is “Short”. If no jumper cap is placed on the pins, the jumper is “Open”. The illustration shows a 3-pin jumper whose pin1 and pin2 are “Short” when a jumper cap is placed on these 2 pins.
  • Page 30: Onboard Headers And Connectors

    2.8 Onboard Headers and Connectors Onboard headers and connectors are NOT jumpers. Do NOT place jumper caps over these headers and connectors. Placing jumper caps over the headers and connectors will cause permanent damage to the motherboard. System Panel Header Connect the power switch, PLED+ PLED-...
  • Page 31 AM5D4ID-2T/BCM AM5D4ID-2L+/BCM Auxiliary Panel Header This header supports mul- ALED1 LAN1_LINK_P (9-pin ITX_AUX PANEL1) tiple functions on the front LAN2_LINK_P BLK_TXRX (see p.6, No. 20) panel, including front panel SMB, internet status indica- tor. SYSTEM_FAULT_LED_P SYSTEM_FAULT_LED_N R_CASEOPEN IntA_PA_D+ USB 3.2 Gen1 Header Besides two default USB IntA_PA_D- (19-pin USB3_3_4)
  • Page 32 SPI TPM Header This connector supports SPI SPI_DQ2 SPI_CS0 (13-pin TPM_BIOS_PH1) Trusted Platform Module SPI_MISO RSMRST# (see p.6, No. 13) (TPM) system, which can securely store keys, digital SPI_TPM_CS# certificates, passwords, and data. A TPM system also helps enhance network TPM_PIRQ RST# security, protects digital...
  • Page 33 AM5D4ID-2T/BCM AM5D4ID-2L+/BCM UID Button Header This header is used for UID LOCATORLED- (5-pin UID_HD) LOCATORBTN# button features. +5VSB (see p.6, No.27) ALERT PSU SMBus Header PSU SMBus header SMBCLK (5-pin PSU_SMB1) monitors the status of the (see p.6, No.1) power supply, fan and SMBDATA system temperature.
  • Page 34 ATX 12V Power Connectors This motherboard provides (8-pin ATX12V1) one 8-pin and one 4-pin (see p.6, No. 5) ATX 12V power connectors. (8-pin ATX12V2 (see p.6, No. 6) ATX 4-PIN Power The motherboard provides ATX_PG Connector one 4-pin power/signal (4-pin ATX4PIN1) connector which is a +5VSB PSON#...
  • Page 35 AM5D4ID-2T/BCM AM5D4ID-2L+/BCM SATA Power Connector Please use a SATA power (4-pin SATA_PWR1) cable to connect this (see p.6, No. 7) SATA Power Connector +12V and the SATA HDD for supplying power from the motherboard, when using DC-IN mode without SATA power supply.
  • Page 36: Atx Psu / Dc-In Power Connections

    2.9 ATX PSU / DC-IN Power Connections This motherboard supports both +12V DC and ATX power input. Please refer to the table below for the required connections between the motherboard and the power supply. Connector DC-IN ATX PSU 12V 8pin ATX 4pin (with the bundled ATX 24pin-to-4pin converter cable)
  • Page 37: Ssd Module Installation Guide

    AM5D4ID-2T/BCM AM5D4ID-2L+/BCM 2.10 M.2 SSD Module Installation Guide The M.2 Socket (M2_1, Key M) supports type 2280 M.2 PCI Express module up to Gen4 x4 (16GT/s x4). Installing the M.2 SSD Module Step 1 Prepare a M.2 SSD module and the screw.
  • Page 38: Dual Lan And Teaming Operation Guide

    2.11 Dual LAN and Teaming Operation Guide Dual LAN with Teaming enabled on this motherboard allows two single connections to act as one single connection for twice the transmission bandwidth, making data transmission more effective and improving the quality of transmission of distant images. Fault tolerance on the dual LAN network prevents network downtime by transferring the workload from a failed port to a working port.
  • Page 39: Chapter 3 Uefi Setup Utility

    AM5D4ID-2T/BCM AM5D4ID-2L+/BCM Chapter 3 UEFI Setup Utility 3.1 Introduction This section explains how to use the UEFI SETUP UTILITY to configure the system. The UEFI chip on the motherboard stores the UEFI SETUP UTILITY. Run the UEFI SETUP UTILITY when starting up the computer. Please press <F2> or <Del> during the Power-On- Self-Test (POST) to enter the UEFI SETUP UTILITY;...
  • Page 40: Navigation Keys

    3.1.2 Navigation Keys Please check the following table for the function description of each navigation key. Navigation Key(s) Function Description Moves cursor left or right to select Screens Moves cursor up or down to select items + / - To change option for the selected items <Tab>...
  • Page 41: Main Screen

    AM5D4ID-2T/BCM AM5D4ID-2L+/BCM 3.2 Main Screen Once entering the UEFI SETUP UTILITY, the Main screen will appear and display the sys- tem overview. The Main screen provides system overview information and allows user to set the system time and date. Because the UEFI software is constantly being updated, the following UEFI setup screens and descriptions for reference purpose only, and may vary from the latest...
  • Page 42 3.2.1 Motherboard Information Press [Enter] to view the information of the motheboard. 3.2.2 Processor Information Press [Enter] to view the information of the processor.
  • Page 43 AM5D4ID-2T/BCM AM5D4ID-2L+/BCM 3.2.3 Memory Information Press [Enter] to view the information of the memory.
  • Page 44: Advanced Screen

    3.3 Advanced Screen In this section, set the configurations for the following items: CPU Configuration, Chipset Configuration, NVMe Configuration, ACPI Configuration, USB Configuration, Super IO Configuration, Serial Port Console Redirection, H/W Monitor, PCI Subsystem Settings, AMD CBS, Network Stack Configuration, Driver Health, Tls Auth Configuration, AMD PBS, AMD Overclocking and Instant Flash.
  • Page 45: Cpu Configuration

    AM5D4ID-2T/BCM AM5D4ID-2L+/BCM 3.3.1 CPU Configuration PSS Support Use this item to enable or disable the generation of ACPI _PPC, _PSS, and _PCT objects. NX Mode Use this item to enable or disable No-execute page protection Function. SVM Mode Use this item to enable or disable CPU Virtualization.
  • Page 46: Chipset Configuration

    3.3.2 Chipset Configuration AMD PCIE Link Width Displays PCIE Link Width information. AMD PCIE Link Speed Use this item to configure PCIE Link Speed. The default value is [Auto]. OnBoard Lan Use this to enable or disable the Onboard LAN function. SPI/fTPM Switch To select 0:AMD CPU fTPM, 1: AMD CPU HSP or 2: Route to SPI TPM.
  • Page 47: Nvme Configuration

    AM5D4ID-2T/BCM AM5D4ID-2L+/BCM 3.3.3 NVMe Configuration NVMe Configuration The NVMe Configuration displays the NVMe controller and Drive information.
  • Page 48: Acpi Configuration

    3.3.4 ACPI Configuration PCIE Devices Power On This Allows the system to be waked up by a PCIE device and enable wake on LAN. RTC Alarm Power On This Allows the system to be waked up by the real time clock alarm. Set it to By OS to let it be handled by the operating system.
  • Page 49: Usb Configuration

    AM5D4ID-2T/BCM AM5D4ID-2L+/BCM 3.3.5 USB Configuration USB Configuration The USB Configuration displays the USB Controllers and USB Device informations.
  • Page 50: Super Io Configuration

    3.3.6 Super IO Configuration Serial Port 1 Configuration Use this item to set parameters of Serial Port 1 (COM1). Serial Port Use this item to enable or disable the serial port. Serial Port Address Use this item to select an optimal setting for Super IO device. SOL Configuration Use this item to set parameters of SOL.
  • Page 51: Serial Port Console Redirection

    AM5D4ID-2T/BCM AM5D4ID-2L+/BCM 3.3.7 Serial Port Console Redirection COM1 / SOL Console Redirection Use this option to enable or disable Console Redirection. If this item is set to Enabled, it allows user to select a COM Port to be used for Console Redirection. Console Redirection Settings Use this option to configure Console Redirection Settings, and specify how the computer and the host computer to which are connected exchange information.
  • Page 52 Bits Per Second Use this item to select the serial port transmission speed. The speed used in the host computer and the client computer must be the same. Long or noisy lines may require lower transmission speed. The options include [9600], [19200], [38400], [57600] and [115200]. Data Bits Use this item to set the data transmission size.
  • Page 53 AM5D4ID-2T/BCM AM5D4ID-2L+/BCM Out-of-Band Mgmt Port Microsof t Windows Emergency Management Services (EMS) allows for remote management of a Windows Server OS through a serial port. Terminal Type EMS Use this item to select the preferred terminal emulation type for out-of-band management. It is recommended to select [VT-UTF8].
  • Page 54: H/W Monitor

    3.3.8 H/W Monitor In this section, it allows user to monitor the status of the hardware on the system, includ- ing the parameters of the CPU temperature, motherboard temperature, CPU fan speed, chassis fan speed, and the critical voltage.
  • Page 55: Pci Subsystem Settings

    AM5D4ID-2T/BCM AM5D4ID-2L+/BCM 3.3.9 PCI Subsystem Settings Above 4G Decoding Use this item to enable or disable 64bit capable Devices to be decoded in Above 4G Address Space (only if the system supports 64 bit PCI decoding). Re-Size BAR Support If system has Resizable BAR capable PCIe Devices, this option Enables/Disables Resizable BAR support.
  • Page 56: Amd Cbs

    3.3.10 AMD CBS CPU Common Options Use this item to configure CPU common options. DF Common Options Use this item to configure DF common options. UMC Common Options Use this item to configure UMC common options. NBIO Common Options Use this item to configure NBIO common options. FCH Common Options Use this item to configure FCH common options.
  • Page 57: Network Stack Configuration

    AM5D4ID-2T/BCM AM5D4ID-2L+/BCM 3.3.11 Network Stack Configuration Network Stack Enable UEFI network stack can prevents user from performing single-user network boots and network installation. If disabled, the host does not use the network interface. IPv4 PXE Support Enable IPv4 PXE Boot support. If disabled, IPv4 PXE Boot Option is not supported. IPv4 HTTP Support Enable IPv4 HTTP Boot support.
  • Page 58: Driver Health

    3.3.12 Driver Health Broadcom NXE Gigabit Ethernet Driver Healthy Provides Health Status for the Drivers/Controllers. AMD GOP X64 Rel Driver Rev.3.6.2.Oct 18 2022.05:39:00 Healthy Provides Health Status for the Drivers/Controllers.
  • Page 59: Tls Auth Configuration

    AM5D4ID-2T/BCM AM5D4ID-2L+/BCM 3.3.13 Tls Auth Configuration Server CA Configuration Press <Enter> to configure Server CA. Enroll Cert Press <Enter> to enroll cert. Delete Cert Press <Enter> to delete cert. Client Cert Configuration Press <Enter> to configure Client Cert.
  • Page 60: Amd Pbs

    3.3.14 AMD PBS AMD Firmware Version Show all of AMD Firmware Version. Graphics Features Graphics Features - HG, DGPU Features, BOMAC0. Platform Firmware Update Use this item to process Platform Firmware Update Discrete USB4 Features Discrete USB4 Features - PCIe resource, D3 support, Native USB4 suport and so on. Unused GPP Clocks Off Turn Unused GPP Clocks Off.
  • Page 61 AM5D4ID-2T/BCM AM5D4ID-2L+/BCM MITT/WITT Selection Use this item to configure MITT/WITT Selection ACP Power Gating Use this item to enable or disable ACP Power Gating. ACP CLock Gating Use this item to enable or disable ACP CLOCK Gating. Thunderbolt Add-in Card Enable Thunderbolt AR/TR Add-in Card Support.
  • Page 62: Amd Overclocking

    3.3.15 AMD Overclocking The AMD Overclocking menu accesses options for configuring CPU frequency and voltage.
  • Page 63: Instant Flash

    AM5D4ID-2T/BCM AM5D4ID-2L+/BCM 3.3.16 Instant Flash Instant Flash is a UEFI flash utility embedded in Flash ROM. This convenient UEFI update tool allows user to update system UEFI without entering operating systems first like MS- ® DOS or Windows . Just save the new UEFI file to the USB flash drive, floppy disk or hard drive and launch this tool, then update the UEFI only in a few clicks without preparing an additional floppy diskette or other complicated flash utility.
  • Page 64: Security

    3.4 Security In this section, set or change the supervisor/user password for the system. For the user pass- word, it also allows user to clear it. Supervisor Password Set or change the password for the administrator account. Only the administrator has author- ity to change the settings in the UEFI Setup Utility.
  • Page 65: Install Default Secure Boot Keys

    AM5D4ID-2T/BCM AM5D4ID-2L+/BCM 3.4.1 Install Default Secure Boot Keys Please install default secure boot keys if it is the first time to use secure boot. Select Clear Secure Boot keys item to clear the asigned secure boot keys.
  • Page 66: Clear Secure Boot Keys

    3.4.2 Clear Secure Boot Keys Force System to Setup Mode - clear all Secure Boot Variables. Change takes effect after reboot.
  • Page 67: Key Management

    AM5D4ID-2T/BCM AM5D4ID-2L+/BCM 3.4.3 Key Management In this section, expert users can modify Secure Boot Policy variables without full authentica- tion. Factory Key Provision Install factory default Secure Boot Keys after the platform reset and while the system is in Setup mode. Install Default Secure Boot Keys Please install default secure boot keys if it’s the first time to use secure boot.
  • Page 68 Platform Key (PK) Enroll Factory Defaults or load certificates from a file: 1. Public Key Certificate in: a) EFI_SIGNATURE_LIST b) EFI_CERT_X509 (DER) c) EFI_CERT_RSA2048 (bin) d) EFI_CERT_SHAXXX 2. Authenticated UEFI Variable 3. EFI PE/COFF Image(SHA256) Key Source: Factory, Modified, Mixed Key Exchange Keys (KEK) Enroll Factory Defaults or load certificates from a file: 1.
  • Page 69 AM5D4ID-2T/BCM AM5D4ID-2L+/BCM 2. Authenticated UEFI Variable 3. EFI PE/COFF Image(SHA256) Key Source: Factory, Modified, Mixed Forbidden Signatures (dbx) Enroll Factory Defaults or load certificates from a file: 1. Public Key Certificate in: a) EFI_SIGNATURE_LIST b) EFI_CERT_X509 (DER) c) EFI_CERT_RSA2048 (bin) d) EFI_CERT_SHAXXX 2.
  • Page 70 b) EFI_CERT_X509 (DER) c) EFI_CERT_RSA2048 (bin) d) EFI_CERT_SHAXXX 2. Authenticated UEFI Variable 3. EFI PE/COFF Image(SHA256) Key Source: Factory, Modified, Mixed...
  • Page 71: Server Mgmt

    AM5D4ID-2T/BCM AM5D4ID-2L+/BCM 3.5 Server Mgmt Wait For BMC Wait For BMC response for specified time out. BMC starts at the same time when BIOS starts during AC power ON. It takes around 90 seconds to initialize Host to BMC interfaces. FRB-2 Timer Select this item to enable or disable FRB-2 timer (POST timer) FRB-2 Timer Timeout...
  • Page 72 OS Wtd Timer Policy Configure how the system should respond if the OS Boot Watchdog Timer expires. If the OS Boot Watchdog Timer is disabled, this item is not available. BMC Network Configuration Select this item to configure BMC network parameters. System Event Log Press <Enter>...
  • Page 73: Bmc Network Configuration

    AM5D4ID-2T/BCM AM5D4ID-2L+/BCM 3.5.1 BMC Network Configuration Bonding Setting Select this item to enabled or disabled bonding. Please enable all lan channel first when want to enable bonding. Lan Channel (Failover) Manual Setting IPMI LAN If [No] is selected, the IP address is assigned by DHCP. Using a static IP address, toggle to [Yes], and the changes take effect after the system reboots.
  • Page 74 When [DHCP] or [Static] is selected, do NOT modify the BMC network settings on the IPMI web page. The default login information for the IPMI web interface is: Username: admin Password: admin For more instructions on how to set up remote control environment and use the IPMI man- agement platform, please refer to the IPMI Configuration User Guide or go to the Support website at: http://www.asrockrack.com/support/ipmi.asp VLAN...
  • Page 75: System Event Log

    AM5D4ID-2T/BCM AM5D4ID-2L+/BCM 3.5.2 System Event Log SEL Components Change this to enable ro disable event logging for error/progress codes during boot. Erase SEL Use this to choose options for earsing SEL. When SEL is Full Use this to choose options for reactions to a full SEL. Log EFI Status Codes Use this item to disable the logging of EFI Status Codes or log only error code or only progress code or both.
  • Page 76: Bmc Tools

    3.5.3 BMC Tools KCS control Select the KSC interface state after POST end. If [Enabled] is selected, the BMC will remain KCS interface after POST stage. If [Disabled] is selected, the BMC will disable KCS interface after POST stage. Restore AC Power Loss This allows user to set the power state after an unexpected AC/power loss.
  • Page 77: Boot Screen

    AM5D4ID-2T/BCM AM5D4ID-2L+/BCM 3.6 Boot Screen In this section, it will display the available devices on the system for user to configure the boot settings and the boot priority. Boot Option #1/#2/#3/#4/#5/#6 Use this item to set the system boot order. UEFI Application Boot Priorities Specifies the Boot Device Priority sequence from available UEFI Application.
  • Page 78: Csm Parameters

    3.6.1 CSM Parameters CSM (Compatibility Support Module) Enable to launch the Compatibility Support Module. If using Windows 8 64-bit UEFI and all of the devices support UEFI, it may also disable CSM for faster boot speed. Launch PXE OpROM Policy Select UEFI only to run those that support UEFI option ROM only.
  • Page 79: Exit Screen

    AM5D4ID-2T/BCM AM5D4ID-2L+/BCM 3.7 Exit Screen Save Changes and Exit When selecting this option, the following message “Save configuration changes and exit setup?” will pop-out. Press <F10> key or select [Yes] to save the changes and exit the UEFI SETUP UTILITY. Discard Changes and Exit When selecting this option, the following message “Discard changes and exit setup?”...
  • Page 80: Chapter 4 Software Support

    Please download the operating system from the OS manufacturer. Please refer to the OS documentation for more instructions. * Please download the Intel® SATA Floppy Image driver from the ASRock Rack’s website (www.asrockrack.com) to the USB drive while installing OS in SATA RAID mode.
  • Page 81: Chapter 5 Troubleshooting

    1. Verify if the battery on the motherboard provides ~3VDC. Install a new battery if it does not. 2. Confirm whether the power supply provides adaquate and stable power. Other problems... 1. Try searching keywords related to the problem on ASRock Rack’s FAQ page: http://www.asrockrack.com/support...
  • Page 82: Technical Support Procedures

    5.2 Technical Support Procedures If having tried the troubleshooting procedures mentioned above and the problems are still unsolved, please contact ASRock Rack’s technical support with the following information: 1. Contact information 2. Model name, BIOS version and problem type. 3. System configuration.