RAS-SH07QHLAE
RAS-SH09RHLAE
RAS-SH12RHLAE
RAS-SH07QHLAE
RAC-SH09WHLAE
RAC-SH12WHLAE
INDOOR UNIT
OUTDOOR UNIT
(Multi Only)
REFER TO THE SPECIFICATION
OUTDOOR
APRIL 2021
RAS-SH07QHLAE/(MULTI ONLY)
RAS-SH09RHLAE/RAC-SH09WHLAE
RAS-SH12RHLAE/RAC-SH12WHLAE
INDOOR UNIT
OUTDOOR UNIT
RAS-SH09RHLAE
RAC-SH09WHLAE RAS-SH12RHLAE RAC-SH12WHLAE
670
2.90
2.6
9000 (5100 - 10500)
880
3.80
3.2
11000 (5450 - 15000)
29-17/32"
35-7/16"
(900)
(750)
11-13/16"
22-7/16"
(300)
(570)
11-1/32"
9-1/16"
(230)
(280)
24.3 (11)
72.8 (33)
0751E
INDOOR UNIT
OUTDOOR UNIT
975
4.20
3.5
12000 (5150 - 14000)
1160
5.00
4.1
14000 (5500 - 18000)
29-17/32"
35-7/16"
(900)
(750)
11-13/16"
22-7/16"
(300)
(570)
11-1/32"
9-1/16"
(230)
(280)
24.3 (11)
72.8 (33)

Advertisement

loading

Summary of Contents for Hitachi RAS-SH07QHLAE

  • Page 1 0751E RAS-SH07QHLAE/(MULTI ONLY) RAS-SH09RHLAE/RAC-SH09WHLAE RAS-SH12RHLAE/RAC-SH12WHLAE RAS-SH07QHLAE RAS-SH09RHLAE RAS-SH12RHLAE RAC-SH09WHLAE RAC-SH12WHLAE INDOOR UNIT OUTDOOR UNIT INDOOR UNIT OUTDOOR UNIT INDOOR UNIT OUTDOOR UNIT (Multi Only) RAS-SH07QHLAE RAS-SH09RHLAE RAC-SH09WHLAE RAS-SH12RHLAE RAC-SH12WHLAE 2.90 4.20 9000 (5100 - 10500) 12000 (5150 - 14000) 1160 3.80...
  • Page 6 RAS-SH07QHLAE RAC-SH09WHLAE RAS-SH09RHLAE RAC-SH12WHLAE RAS-SH12RHLAE ASD102SKQA6JK6 40.57oz (1150g) PIPES Additional 0.005lb/ft (7g/m) after (Refrigerant R410A) (MAX. 82ft (25m)) 26.2ft (8m) length...
  • Page 51 MODEL RAS-SH07QHLAE RAS-SH09RHLAE RAS-SH12RHLAE...
  • Page 52 MODEL RAC-SH09WHLAE RAC-SH12WHLAE...
  • Page 53 RAS-SH07QHLAE, RAS-SH09RHLAE, RAS-SH12RHLAE RAS-SH07QHLAE, RAS-SH09RHLAE, RAS-SH12RHLAE RAC-SH09WHLAE, RAC-SH12WHLAE...
  • Page 54 COMPRESSOR MOTOR Com p ressor Motor S p ecifications RAC-SH09WHLAE MODEL RAC-SH12WHLAE COMPRESSOR MODEL ASD102SKQA6JK6 PHASE SINGLE RATED VOLTAGE AC 220 - 240V RATED FREQUENCY 60 Hz POLE NUMBER CONNECTION YELLOW ° 2M = 2.167 ° (6 8 RESISTANCE VALUE ( 1 6 7 °...
  • Page 55 MODEL RAS-SH09RHLAE MODEL RAC-SH09WHLAE RAS-SH12RHLAE RAC-SH12WHLAE RAS-SH07QHLAE (2A) F3(2A) (BLK) (25A) F6(3.15A) F5(3.15A)
  • Page 56 BAT0 COM4 COM3 COM4 COM3 BAT1 COM5 COM2 100K COM5 COM2 COM6 COM1 COM6 COM1 COM7 COM0 COM7 COM0 BAT0 BAT1 SEG0 SEG13 L85 50QLT1G SEG0 SEG13 SEG1 SEG14 SEG1 SEG14 SEG2 SEG15 S8050 SEG2 SEG15 SEG3 SEG16 SEG3 SEG16 SEG4 SEG17 100K...
  • Page 57 CIRCUIT DIAGRAM MODEL RAS-SH07QHLAE RAS-SH09RHLAE RAS-SH12RHLAE BOARD TYPE DRAWING FORM #INSERT-AS DD0010111A A,R,C,S MAIN PWB #BOARD-AS DD0010318A RESISTOR RESISTOR XH-7P(Top)WHT CAPACITOR DIODE 2、3pin(none) VALUE ASSY. VALUE ASSY SYMBOL TOLERANCE WATT FORM GROUP REMARK SYMBOL TOLERANCE WATT FORM GROUP REMARK (Ω) (Ω)
  • Page 58 MAIN-PCBA HIC-PCBA HEATER-PCBA Capacitor Resistor Capacitor Transistor Resistor Resistor Rate Rate Rate Rate Rate Symbol Symbol Symbol Symbol Resistance Tolerance Electric power Symbol Capacity Voltage Type Symbol Model type Resistance Tolerance Electric power Capacity Voltage Type Resistance Tolerance Electric power R001 1.43M C001...
  • Page 59 RAS-SH07QHLAE, RAS-SH09RHLAE, RAS-SH12RHLAE &...
  • Page 60: Top Side

    MAIN PWB MODEL RAC-SH09WHLAE RAC-SH12WHLAE Bottom side Top side...
  • Page 61 HIC PWB Top side Bottom side...
  • Page 62 RELAY PWB MODEL RAC-SH09WHLAE RAC-SH12WHLAE Top side Bottom side...
  • Page 63 1Ø 230V 60Hz Frost Wash Humidity...
  • Page 71 RAS-SH07QHLAE / (MULTI ONLY) RAS-SH09RHLAE / RAC-SH09WHLAE RAS-SH12RHLAE / RAC-SH12WHLAE COOLING, DEHUMIDIFYING, DEFROSTING OUTDOOR UNIT INDOOR UNIT S-TANK COMP ACCUMULATOR REV-VALVE 3S-VALVE 9.52mm (3/8") ACCUMULATOR THERMISTOR THERMISTOR EXPANSION VALVE 2S-VALVE 6.35mm (1/4") STRAINER SILENCER HEATING OUTDOOR UNIT INDOOR UNIT S-TANK...
  • Page 78 R672 R660 CN5H CN21...
  • Page 79 R343...
  • Page 81 CN12...
  • Page 82 Microcomputer R800...
  • Page 85 MODEL RAC-SH09WHLAE,RAC-SH12WHLAE 1. Power Circuit. リアクタ 5.3mH WH12−1 WH12−2 WH7 MAIN BOARD WH6 WH102 WH101 WH8 WH−E−5 WH9 WH−E−6 Q601 WH10 WH−E−7 D603 D601 WH−E−8 COMPRESSOR MOTOR TH001 Q901 Q902 Q903 NF1 JW601 WH11 F1 U Q602 RL4 D604 D602 V...
  • Page 87 Q904, Q905, Q906 Q901, Q902, Q903 LD301 5P-TERMINAL DB602 Q602 HIC PWB Q601 Smoothing Capacitor (C021, C022) Because high voltage flows, be careful about electric shock. Also,be careful about short-circuit accidents by improper connection of measuring instruments, which can damage the board. 3.
  • Page 93 8. Base Heater Circuit Relay PCB FU5(3A Fuse) 3 Base Heater AC230V 1 Temp. Fuse protector Heater relay VH3P Fig 8-1 When the outdoor temperature is lower than a certain temperature, the base heater begins to work and the defrosting ability is enhanced. When the outdoor temperature is higher than a certain temperature (7±3°C), the protector will work arel.
  • Page 96 (4) Remove the two lock screws from the fan motor holder and one screw from the evaporator support plate. (5) Pull up the evaporator by holding it at the lower side. Insert a screwdriver through the space between the evaporator and fan motor holder and loosen the fan lock screws to remove the air flow fan and fan motor.
  • Page 97 CN12 CN18 CN16A CN12 CN17 CN16A...
  • Page 98: Procedure For Disassembly And Reassembly

    Procedure for Disassembly and Reassembly OUTDOOR UNIT MODEL RAC-SH09WHLAE,RAC-SH12WHLAE 2. Dismantle procedure of MAIN PWB. (1) Remove terminal cover. 1. Electrical Parts (1) Remove the top cover fixing screws Terminal Cover and lift the cover to remove it. (2) Remove the handle cover fixing screws and push it down to take it out.
  • Page 99 (4) Remove each connector and earth cable from the lead wire.Then,remove the electrical box. Fig.13 3. The PWB. (1) Remove the electrical cover. detents Fig.14 (2) Remove the PWB from the support. detents detents Fig.15...
  • Page 108 While pressing and holding (ON/OFF) button and button, press [RESET] button on the same. Release [RESET] button only and make sure that all marks on the remote controller display are indicated then release the (ON/OFF) button and button. Remote controller now enters "Shift Value Change Mode". Press the (MODE) selector button so that the display indicates (FAN) mode.
  • Page 109 SETTING THE PREVENTION OF MUTUAL INTERFERENCE FOR REMOTE CONTROLLER a.) Other indoor circuit breakers should be disconnected. b.) Remove the back cover of the remote control. c.) Cut the jumper as shown below. d.) Press “Reset” button after installing the battery. e.) Corresponding to the room electrical box dial code 6 to dial on.
  • Page 110 HOW TO CHANGE THE FAN SPEED IN COOLING MODE DURING THERMO OFF The fan speed in Cooling Mode during thermo off can be changed by the remote controller. (This procedure shall be implemented strictly by service personnel only.) It is possible to return it to the default setting. PROCEDURE Press [POWERFUL] button and...
  • Page 111 HOW TO CHANGE THE INTERMITTENT FAN HEATING SETTING The intermittent fan control during thermo o in Heating mode can be changed by the remote controller. (The procedure should be done only by service personnel.) It is possible to select from 3 patterns. PROCEDURE Press (POWERFUL) button,...
  • Page 112 DISPLAY OPERATION MODE SETTING For operating indoor unit independently (without outdoor unit connection), remote controller must be set according to below procedures before send the signal to the indoor unit. New communication format between indoor and outdoor is required to communicate with outdoor unit.
  • Page 131 How to run the product with the outdoor unit test switch If the indoor electrical parts is out of order and if you wish to run the outdoor unit. 1. Turn OFF main power supply. 2. Unplug the CN18 and CN3 connector. 3.
  • Page 134 MODEL : RAS-SH07QHLAE RAS-SH09RHLAE RAS-SH12RHLAE...
  • Page 135 MODEL RAS-SH07QHLAE, RAS-SH09RHLAE, RAS-SH12RHLAE PART NO. Q'TY / UNIT PARTS NAME PMRAS-S18CPA AUTO SWEEP MOTOR PMRAK-50PPD TANGENTIAL FLOW FAN PMRAK-50PPD FILTER PMRAK-50PPD TERMINAL BOARD (3P) PMRAS-25YH4 SPRING PMRAS-25YH4 P-BEARING ASSY PMS-SH09RHLAE PWB RECEIVER PMS-SH09RHLAE FAN MOTOR PMS-SH09RHLAE FRONT COVER ASSY...
  • Page 136 MODEL : RAC-SH09WHLAE RAC-SH12WHLAE...
  • Page 137 MODEL RAC-SH09WHLAE, RAC-SH12WHLAE PART NO. Q'TY / UNIT PARTS NAME C ABINET S 04 PMRAM-33NP2E FAN MOTOR PMRA C -XH18 C KT S 02 C OMPRE SS OR S 01 PMC-EH09WHLAB C ONDEN S ER PMC-SH09WHLAE S 02 D- G RILL PMRA C -VX10 C J S 04 OVERLOAD RELAY C OVER...
  • Page 138 HITACHI RAS-SH07QHLAE/(MULTI ONLY) PM NO. 0751E RAS-SH09RHLAE/RAC-SH09WHLAE Printed in Malaysia RAS-SH12RHLAE/RAC-SH12WHLAE © 2021 Johnson Controls-Hitachi Air Conditioning, Inc. LIT 12013821...

This manual is also suitable for:

Ras-sh09rhlaeRas-sh12rhlaeRac-sh09whlaeRac-sh12whlae