Download Print this page
Zehnder Rittling Ovida Bow Manual

Zehnder Rittling Ovida Bow Manual

Advertisement

Quick Links

Zehnder Ovida Bow
OVB-080
OVB-120
All dimensions shown are in millimetres
Test pressure:
Max working pressure:
Max working temperature:
All steel construction:
Connections:
Heat output determined in accordance with EN 442
Test Laboratory: 1428WSP
Height
Model
± 2mm
OVB-080-050
796
OVB-080-060
796
OVB-080-075
796
OVB-120-050
1196
OVB-120-060
1196
OVB-120-075
1196
OVB-150-050
1556
OVB-150-060
1556
OVB-185-050
1876
OVB-185-060
1876
Zehnder Group UK Ltd
OVB-150
OVB-185
13 BAR
10 BAR
100º C
dia 25mm x 1.2mm tubes
dia 26mm x 1.5mm tubes
½ inch BSP underside tappings
Pipe
Width
Finish
Centres
± 2mm
± 2mm
496
painted
458
596
painted
558
746
painted
708
496
painted
458
596
painted
558
746
painted
708
496
painted
458
596
painted
558
496
painted
458
596
painted
558
width
return
tapping centres
19
note: flow & return can be reversed if required
Output
Output
ΔT=50K
ΔT=30K
Watts
Btu
Watts
417
1423
224
492
1679
265
601
2051
325
609
2078
325
718
2450
385
878
2996
474
784
2675
417
924
3153
494
3218
943
500
1111
3791
592
Concept House
Tel:
01276 605800
Watchmoor Point
Fax: 01276 24058
Camberley
retailsales@zehnder.co.uk
Surrey GU15 3AD
www.zehnder.co.uk
flow
19
For optional Supplementary Heater
see separate sheet as fitting this will
affect pipe centres.
Please check before drilling.
* rating for simple immersion/CTEC or CTEW in Watts
Water
Content
n
Weight
litres
Btu
kg
764
1.22
8.1
4.3
904
1.21
9.5
5.0
1109
1.20
11.6
6.0
1109
1.23
12.0
6.1
1314
1.22
13.9
7.2
1617
1.21
16.8
8.8
1423
1.24
16.0
8.2
1686
1.23
18.6
9.6
1.24
1706
19.1
9.7
2020
1.23
22.0
11.3
Registered in England: 2296696
122-139
66-83
Allow minimum of
100mm for valves
Max.
Immersion
Rating*
300
300
400
400
500
600
500
600
600
700
Issue 1.0

Advertisement

loading

Summary of Contents for Zehnder Rittling Ovida Bow

  • Page 1 Zehnder Ovida Bow width 122-139 OVB-080 OVB-120 OVB-150 OVB-185 return flow 66-83 tapping centres note: flow & return can be reversed if required Allow minimum of 100mm for valves All dimensions shown are in millimetres For optional Supplementary Heater Test pressure:...
  • Page 2 Zehnder Ovida Bow width 122-139 OVBC-080 OVBC-120 OVBC-150 OVBC-185 return flow 66-83 tapping centres note: flow & return can be reversed if required Allow minimum of 100mm for valves All dimensions shown are in millimetres For optional Supplementary Heater Test pressure:...
  • Page 3 Zehnder Ovida Bow Tools & Material Required Component Suitable valves Bracket Post PTFE tape Spacer Silicone thread sealant Air Vent - 1/8” Tape measure Wall Plug Allen key - 13mm & 12mm (when installing Zehnder valves) Bracket Electric drill Screw - 6mm dia x 50mm...

This manual is also suitable for:

Ovb-080-050Ovb-080-060Ovb-080-075Ovb-120-050Ovb-120-060Ovb-120-075 ... Show all