Specifications - Onkyo A-809 Service Manual

Integrated stereo amplifier
Hide thumbs Also See for A-809:
Table of Contents

Advertisement

A-809
SPECIFICATIONS
Power Output:
105 watts per channel, min. RMS, at 8 ohms,
both channels driven from 20 Hz to 20 kHz,
with no more than 0.008% Total harmonic
distortion.
Dynamic Power:
303 watts at 2 ohms,
235 watts at 4 ohms
155 watts at 8 ohms
Total Harmonic
Distortion
0.008% at rated power
0.008% at 1 watt output
Intermodulation
Distortion: 0.005% at rated power
Damping Factor:
150 at 8 ohms (1 kHz)
Input Sensitivity/
Phono (MM):
2.5 mV/50 kohms
Impedance:
Phono (MC):
160 2V/130 ohms
CD:
150 mV/30 kohms
TUNER:
150 mV/30 kohms
Tape Play:
150 mV/30 kohms
Output Level/Impedance:
Tape Rec:
150 mV/1.0 kohms
(Phono)
Phono Overload:
Phono (MM):
200 mV RMS. at 1 kHz,
0.012% THD.
Tone Control
(Vol -20 dB):
BASS:
+8 dB at 100 Hz
TREBLE:
£8 dB at 10 kHz
High Cut:
6 kHz (6 dB/Octave) (TREBLE min.)
Frequency Response:
CD, Tuner:
2 Hz-50 kHz
(+0, -1 dB)
RIAA Deviation:
Phono
(MM):
+£0.3 dB, 20 Hz -20 kHz
Subsonic Filter:
20Hz (-3dB, 6dB/Oct)
Signal to Noise
Phono (MM):
94 dB (5.0 mV input)
Ratio (!HF-A):
Phono (MC):
75 dB (0.5 mV input)
2
CD (DIRECT):
107 dB
Attenuator:
~20 dB
Muting:
oo
Power Supply:
European models:
AC230V, 50 Hz
U.S.A & Canadian models:
AC120V, 60 Hz
U.K & Australia models:
AC240V,
50 Hz
Worldwide models:
AC120 and 220V
switchable, 50/60 Hz
Dimensions
(W x H x
D):455
x 170
x 420 mm
17-15/16"
x 6-11/16"
x 16-9/16"
Weight:
16.7 kg, 36.8 Ibs.
PRECAUTIONS
1. Replacing the fuses
For continued protection against risk fire, replace only with same type and same rating fuse.
CIRCUIT NO.
PART NO.
DESCRIPTION
F9O1
252052
7A ST-6, Primary fuse (120V, 120V/220V model)
F901
252075
2.5A-SE-EAK, Primary fuse (230V model)
F902
252077
4A-SE-EAK, Primary fuse (230V, 240V, 120V/220V model)
2. Insulation resistance mesurement (Only U.S.A. model)
Connect the insulating-resistance tester hetween the plug of power supply cable and the terminal GND on the back panel. Specifications,
More than 10 MQ at 500V.
3. Voltage selector (rear panel)
Worldwide models are equipped with a voltage selector to conform with local power supplies. Be sure to set this switch to match the voltage
of the power supply in your area before turning the power switch on. Voltage is changed by sliding the groove in the switch with a screwdriver
to the up or down. Confirm that the switch has been moved all the way to the up or down before turning the power switch on. Models without
a voltage selector can only be used in areas where the power supply is the same as that of the unit.
220V ~
220V ~
at AC 220V
at AC 120V
120V ~
120V ~