Webasto ABC-600NS Installation, Operation And Maintenance Manual page 38

Ev test systems
Table of Contents

Advertisement

ABC-600NS
that the DC Converter be placed in Standby Mode (STANDBY button(s) lit, while
other mode buttons are unlit) first before turning off the power.
Once the input power has been turned off, leave the MAIN POWER OFF switch
light on and/or the EMERGENCY OFF button depressed until all indicator lights
on the front panel go off. This allows the high voltage within the system to
dissipate (through a bleed resistor) so the system will be safe for maintenance.
WARNING
31565-03_01
User must make sure that the AC circuit breaker is off and the
system has been off with the ON/OFF or EMERGENCY OFF
button in the OFF POSITION for a minimum of five minutes
before opening cabinet for service.