Webasto ABC-600 Installation, Operation And Maintenance Manual page 49

Ev test systems
Hide thumbs Also See for ABC-600:
Table of Contents

Advertisement

ABC-600
Power Mode
Voltage Level
4.5 V <= (Analog V) <= 5.0 V
0.5 V <= (Analog V) <= 4.5 V
-0.5 V <= (Analog V) <= 0.5 V
-4.5 V <= (Analog V) <= -0.5 V
-4.5 V <= (Analog V) <= -5.0 V
3.
PLower limit <= Output Power =< PUpper limit
4.
Power commanded by the user via Front panel or ROS
(See Figure IV-2)
ABC-600 in Power Mode with Analog Input
17032-03-D
Scaling Equation
Output Power
3
= Power
Output Power = Power + PUpper limit *[((Analog V)-0.5) /
4]
Output Power = Power
Output Power = Power + PLower limit *[(|Analog V|)-0.5) /
4]
Output Power = Power + PLower limit
Figure IV-2 Power Mode
Page 49 of 51
Installation, Operation and Maintenance
4
+ PUpper limit
Webasto Charging Systems, Inc.