Channel A and Channel B can be used as source or sink. When Channel A is used as
source and B as sink or vise versa, the positive and negative terminals of Channel A are
connected to corresponding terminals of Channel B.
Follow the steps shown below for connecting Channel A to Channel B.
1) Prepare 2 cables with appropriate male connectors on either end that mate with
those provided on PPS unit. One cable should have red male terminals on either
side and the other should have black male connectors on either side.
2) Plug in Channel A positive Red terminal first.
3) Next plug in Channel A negative Black terminal.
4) Next plug in Channel B positive Red terminal
5) Next plug in Channel B negative Black terminal
The steps 2 to 5 could be altered as shown below.
2) Plug in Channel B positive Red terminal first.
3) Next plug in Channel B negative Black terminal.
4) Next plug in Channel A positive Red terminal
5) Next plug in Channel A negative Black terminal
Damage to the DC power stage will occur if Channel A is connected to Channel B in any
other way than that described above.
17032-03-D
READ THIS ENTIRE SECTION BEFORE PROCEEDING
Battery testers should not rely solely on manual operation or automated
scripts for safety. Errors can subject batteries to overcharging which can
result in battery damage or fire.
Batteries should be monitored by independent hardware for one or more
of these unsafe conditions:
Over voltage
Over temperature
Excess pressure
Excess gassing (H2)
The HV Interlock on the PPS is provided to allow a hardware monitor to
shut down the PPS in the event of an unsafe battery condition.
When the DC output external contact in the load opens in either Current or
Power Mode, the user must put the ABC-600 in Standby Mode before
reclosing the external contact. This can be done manually or in the ROS
script.
The High Voltage Interlock Connector can also be used to put the unit in
Standby Mode. When the High Voltage Interlock connection is opened,
the unit automatically goes into Standby Mode. Refer to the manual and
consult Webasto's Customer Service Department, if necessary.
Failing to put the ABC-600 in Standby Mode may cause serious damage
to the unit.