Summary of Contents for Zenitel Marine Master Clock 70000
Page 1
MASTER CLOCK SYSTEM TECHNICAL & USER MANUAL TECHNICAL MANUAL A100K10807...
Page 2
Document Scope This document describes the installation and programming of the following products: Product Description Item No. Marine Master Clock 70000 Marine Master Clock 70000L with Network Time Server Analog NTP Clock with PoE connection Revision Information Rev. Date Author Description V1.0...
Page 6
Document: 1717en21.doc MARINE MASTER CLOCK Author: PM Date: 2022-06-22 User Manual Page: 3 of 57 Important Safeguards Read all these instructions and save them for later use • Do not place this product on an unstable cart, stand or table. The product may fall, causing serious damage to the product and/or person.
Document: 1717en21.doc MARINE MASTER CLOCK Author: PM Date: 2022-06-22 User Manual Page: 7 of 57 Serial ports The Master Clock is equipped with two serial ports, one RS232 and one RS422/485. Both ports can be used either as input or output for serial time messages. If programmed as output the port can be used to send out time to external equipment such as computers etc.
Document: 1717en21.doc MARINE MASTER CLOCK Author: PM Date: 2022-06-22 User Manual Page: 8 of 57 General description Westerstrand Marine Master Clock is the ideal solution for distribution of both Local and UTC time on board ships. The Master Clock is equipped with several outputs and inputs for control of Slave Clocks as well as distribution of time to computers and other equipment needing correct time.
Document: 1717en21.doc MARINE MASTER CLOCK Author: PM Date: 2022-06-22 User Manual Page: 10 of 57 Installation Installation and maintenance of this equipment should only be carried out by qualified personnel. This product is to be connected to mains as a permanent installation and shall be connected by a readily accessible safety switch.
Document: 1717en21.doc MARINE MASTER CLOCK Author: PM Date: 2022-06-22 User Manual Page: 11 of 57 Connection diagram The impulse output voltage is 24V DC and max current is 2A. WESTERSTRAND URFABRIK AB P.O. Box 133 Tel. +46 506 48000 Internet: http://www.westerstrand.se SE-545 23 TÖREBODA Fax.
Document: 1717en21.doc MARINE MASTER CLOCK Author: PM Date: 2022-06-22 User Manual Page: 12 of 57 Programming General Using 6 buttons and a 2-row 16-character display carries out all programming. Programming is self-instructive and to simplify the dialogue Yes/No questions are used.
Document: 1717en21.doc MARINE MASTER CLOCK Author: PM Date: 2022-06-22 User Manual Page: 13 of 57 Start up procedure 1. Startup questions (this page) 2. Output configuration / Setup (page 14) 3. Enter time of Slave Clocks (page 16) STARTING When the Master Clock is connected for the first time correct/requested LANGUAGE language has to be entered.
Document: 1717en21.doc MARINE MASTER CLOCK Author: PM Date: 2022-06-22 User Manual Page: 14 of 57 Output configuration / Setup Each output can be individually configured regarding different parameters. The setup is done from the special function Setup. If the default setup is used no configuration is needed. Default setup: Slave Clock output no.
Document: 1717en21.doc MARINE MASTER CLOCK Author: PM Date: 2022-06-22 User Manual Page: 15 of 57 Set UTC when in operation Select function using ↓. MON 28 MAR 2022 U10:11:35 L12:11 Enter the programming mode with YES. SET UTC Set, by using the arrows, the right UTC. SET UTC Time format: Year, month, date, hour, minute, second.
Document: 1717en21.doc MARINE MASTER CLOCK Author: PM Date: 2022-06-22 User Manual Page: 17 of 57 Time zone adjustment To change Local Time zone two buttons are used. The buttons are named ADV and REV. To advance the Local Time slave clocks to a new time zone press button ADV. Example: MON 28 MAR 2022 Press button ADV.
Document: 1717en21.doc MARINE MASTER CLOCK Author: PM Date: 2022-06-22 User Manual Page: 18 of 57 Alarms This function is used to display and erase the different alarms in the master clock. ALARMS- DISPLAY To show the alarms To erase the alarms ALARMS- ERASE Example 1, display alarms MON 28 MAR 2022...
Document: 1717en21.doc MARINE MASTER CLOCK Author: PM Date: 2022-06-22 User Manual Page: 19 of 57 Example 1, erase alarms MON 28 MAR 2022 Select function using ↑↓ . U10:11:35 L12:11 ALARMS Accept with YES. Press NO until the wished function is shown. ALARMS- ERASE Accept with YES.
Document: 1717en21.doc MARINE MASTER CLOCK Author: PM Date: 2022-06-22 User Manual Page: 20 of 57 Alarm list The following alarms are available Type of alarm Indication Reason for alarm Action NO RADIO 30 Red alarm LED lit. The Master Clock Check the external General alarm relay activated.
Document: 1717en21.doc MARINE MASTER CLOCK Author: PM Date: 2022-06-22 User Manual Page: 21 of 57 Week Program & Date Program Using these two functions, programming of the outputs is made. Concept description Program "program" refers to programming an output to a certain time. The word program represents a single time event, and several programs are defined as a group of programs.
Page 25
Document: 1717en21.doc MARINE MASTER CLOCK Author: PM Date: 2022-06-22 User Manual Page: 22 of 57 To simplify programming 3 sub menus are used: WEEK PROGRAM To enter new programs. GROUP A WEEK PROGRAM To erase a separate existing program. ERASE GROUP A WEEK PROGRAM To change existing programs.
Document: 1717en21.doc MARINE MASTER CLOCK Author: PM Date: 2022-06-22 User Manual Page: 23 of 57 Week Program, example 1 (New program) Example: Outputs No. 2 shall switch on Monday – Friday at 09.00 and off at 17.00. MON 28 MAR 2022 Select function using ↑↓.
Document: 1717en21.doc MARINE MASTER CLOCK Author: PM Date: 2022-06-22 User Manual Page: 24 of 57 Week Program, example 2 (Change program) Example: A signal on output 1, Monday – Friday at 08.00, shall be changed to 08.15. Signal length is 5 seconds. MON 28 MAR 2022 Select function using ↑↓...
Document: 1717en21.doc MARINE MASTER CLOCK Author: PM Date: 2022-06-22 User Manual Page: 25 of 57 Week Program, example 3 (Erase program) Example: A signal on output 1, Fridays at 16.30 shall be deleted. Signal length is 5 seconds. MON 28 MAR 2022 Select function using ↑↓...
Document: 1717en21.doc MARINE MASTER CLOCK Author: PM Date: 2022-06-22 User Manual Page: 26 of 57 Week Program, example 4 (Astronomical function) Example: Output No. 1 shall switch ON all sunset All days and switch OFF at sunrise. MON 28 MAR 2022 Select function using ↑↓...
Document: 1717en21.doc MARINE MASTER CLOCK Author: PM Date: 2022-06-22 User Manual Page: 27 of 57 Week Program, example 5 (Block program) Example: Outputs No. 2 shall switch on Monday, Wednesday and Friday at 09.00. 28 MAR 2022 Select function using ↑↓ . U10:11:00 L12:11 WEEK PROGRAM Enter programming mode using YES.
Document: 1717en21.doc MARINE MASTER CLOCK Author: PM Date: 2022-06-22 User Manual Page: 28 of 57 Week Program, example 6 (Mask program) Example: Outputs No. 2 shall switch on for 5 seconds every hour at minute 15, all days in the week. 28 MAR 2022 Select function using ↑↓...
Document: 1717en21.doc MARINE MASTER CLOCK Author: PM Date: 2022-06-22 User Manual Page: 29 of 57 Date Program, example (New program) Example: Outputs No. 1 shall switch on the 1st of August at 12.00. 28 MAR 2022 Select function using ↑↓ . U10:11:00 L12:11 DATE PROGRAM Enter programming mode using YES.
Document: 1717en21.doc MARINE MASTER CLOCK Author: PM Date: 2022-06-22 User Manual Page: 30 of 57 Display Program 28 MAR 2022 Select function using ↑↓ . U10:11:00 L12:11 DISPLAY PROGRAM Enter display program using YES. DISPLAY PROGRAM Select program group using ↑↓, accept with YES. GROUP A Select output to be displayed using ↑↓, accept with YES.
Document: 1717en21.doc MARINE MASTER CLOCK Author: PM Date: 2022-06-22 User Manual Page: 31 of 57 Temporary Program, example Example: Outputs No. 2 shall switch on immediately 15.35.00 and turn off according to normal week program. The temporary program will automatically be erased when the event has been affected. 28 MAR 2022 Select function using ↑↓...
Document: 1717en21.doc MARINE MASTER CLOCK Author: PM Date: 2022-06-22 User Manual Page: 32 of 57 Group => Period Each program group can be associated to one or several time periods. A time period can consist of one or several dates. Maximum 99 time periods can be used. Program group A is as default associated to a time period covering the complete year, 1/1-31/12.
Document: 1717en21.doc MARINE MASTER CLOCK Author: PM Date: 2022-06-22 User Manual Page: 33 of 57 Spec.-Functions The special functions contain functions used during setup and configuration of the Master Clock. If the default settings are used no configuration is needed. MON 28 MAR 2022 Select function using ↓...
Document: 1717en21.doc MARINE MASTER CLOCK Author: PM Date: 2022-06-22 User Manual Page: 34 of 57 Status With this function each input/output status can be checked. Example: Check the status of the synchronization source receiver. MON 28 MAR 2022 Select function using ↓ . U10:11:35 L12:11 Accept with YES.
Page 38
Document: 1717en21.doc MARINE MASTER CLOCK Author: PM Date: 2022-06-22 User Manual Page: 35 of 57 Status sync. source Type of synchronization % of accepted messages NMEA RS485 60% 01 MAY 12:00:00 Last reception was 01MAY12:00:00*. *Remark: For W-GPS the marked position always shows the actual second. This information is updated every other second.
Document: 1717en21.doc MARINE MASTER CLOCK Author: PM Date: 2022-06-22 User Manual Page: 36 of 57 Language With this function the language will be selected. Example: MON 28 MAR 2022 Select function using ↓ . U10:11:35 L12:11 Accept with YES. SPEC.-FUNCTIONS Press NO until wished function is shown.
Document: 1717en21.doc MARINE MASTER CLOCK Author: PM Date: 2022-06-22 User Manual Page: 37 of 57 Setup With this function the different output and input can be configured. If the default setup is used no configuration is needed. Example: Set the alarm limit for synchronization source alarm to 1 hour. (Default setting is 12 hours.) MON 28 MAR 2022 Select function using ↓...
Page 41
Document: 1717en21.doc MARINE MASTER CLOCK Author: PM Date: 2022-06-22 User Manual Page: 38 of 57 Setup sync. source Below is a description of the different configuration parameters available in the setup menu for sync. source. Please remark that if default settings are used no configuration is needed. Type of synchronization NMEA RS485 AL.
Page 42
Document: 1717en21.doc MARINE MASTER CLOCK Author: PM Date: 2022-06-22 User Manual Page: 39 of 57 Setup impulse output Below is a description of the different configuration parameters available in the setup menu for impulse output. Please remark that if default settings are used no configuration is needed. Impulse type Type of time Type of impulse...
Page 43
Document: 1717en21.doc MARINE MASTER CLOCK Author: PM Date: 2022-06-22 User Manual Page: 40 of 57 Impulse length Configuration of impulse length. 1/1 and 1/2 -minute impulse: 0.1s – 9.9 s. Second impulses: 0.1 – 1.0 s. Alarm limits Impulse current low limit Impulse current high limit IL=0.0 - 2.0A UF= -- V...
Page 44
Document: 1717en21.doc MARINE MASTER CLOCK Author: PM Date: 2022-06-22 User Manual Page: 41 of 57 Setup RS232 and RS485/422 output / input Below is a description of the different configuration parameters available in the setup menu for the RS232 and RS485 input/ output.
Page 45
Document: 1717en21.doc MARINE MASTER CLOCK Author: PM Date: 2022-06-22 User Manual Page: 42 of 57 No. of stop bits, 1 or 2. Available formats: 7N1, 7N2, 7O1, 7O2, 7E1, 7E2, 8N1, 8N2, 8O1, 8O2, 8E1, 8E2, Protocol description ZDA - Time & Date - UTC, Day, Month, Year and Local Time Zone $--ZDA,hhmmss.ss,xx,xx,xxxx,xx,xx*hh<CR><LF>...
Page 46
Document: 1717en21.doc MARINE MASTER CLOCK Author: PM Date: 2022-06-22 User Manual Page: 43 of 57 Protocol 2 The message has length 20 bytes according to: STX F G W 20 YY MM DD HH MM SS ETX BCC F - Flag bits =0 Winter time, =1 summer time =1 Synced from Radio source, e.g.
Page 47
Document: 1717en21.doc MARINE MASTER CLOCK Author: PM Date: 2022-06-22 User Manual Page: 44 of 57 Protocol 3 At second 56 this message will be transmitted: HH:MM:00 SP DD/MN/YY SP NNN SP W CR LF (25 bytes) HH = Hour ‘00’ – ‘23’. = 3AH MM = Minute ’00’...
Page 48
Document: 1717en21.doc MARINE MASTER CLOCK Author: PM Date: 2022-06-22 User Manual Page: 45 of 57 Protocol 7 STX WW VV YYYY MN DD HH MM SS F G BCC ETX (24 bytes) STX = 02h (1 byte). = Week number '01'-'53' = Weekday '01'-'07' YYYY = Year...
Page 49
Document: 1717en21.doc MARINE MASTER CLOCK Author: PM Date: 2022-06-22 User Manual Page: 46 of 57 Protocol 16* STC HH MM SS DD MO MO YY HL HL ML ML ECT Code description Hex value Start Transmission Character Ten UTC hours 30-32 Unit UTC hours 30-39...
Page 50
Document: 1717en21.doc MARINE MASTER CLOCK Author: PM Date: 2022-06-22 User Manual Page: 47 of 57 Setup special pulse Relay output no. 2 can be dedicated to send out a special pulse. When this function is enabled the relay is activated every day for 5 seconds at 02.00 UTC. Use the procedure below to enable the special pulse.
Page 51
Document: 1717en21.doc MARINE MASTER CLOCK Author: PM Date: 2022-06-22 User Manual Page: 48 of 57 Setup NMEA LT This function is valid only if the Master Clock is synchronized from an external NMEA source. Special function sync. source must be set to NMEA RS485 or NMEA RS232. With this function it can be selected if the Master Clock should use the Local Time (LT) information included in the NMEA time message.
Document: 1717en21.doc MARINE MASTER CLOCK Author: PM Date: 2022-06-22 User Manual Page: 49 of 57 SPEC.-FUNCTIONS SETUP ← SPEC.-FUNCTIONS ← MON 28 MAR 2022 U10:11:35 L12:11 Software version This function shows the software version for the Time Base module. MON 28 MAR 2022 Select function using ↓...
Document: 1717en21.doc MARINE MASTER CLOCK Author: PM Date: 2022-06-22 User Manual Page: 50 of 57 Default LT adjust This function is used to enter the default value used when pressing button ADV or REV. Example: Change default LT adj. from 60 minutes to 20 minutes. MON 28 MAR 2022 Select function using ↓...
Document: 1717en21.doc MARINE MASTER CLOCK Author: PM Date: 2022-06-22 User Manual Page: 51 of 57 Display format With this function the display format in running mode can be selected. The following three formats can be selected: Format 1 MON 28 MAR 2022 LT = Local Time.
Document: 1717en21.doc MARINE MASTER CLOCK Author: PM Date: 2022-06-22 User Manual Page: 52 of 57 Programming form Function Group Output Type of signal Day/Date Time WESTERSTRAND URFABRIK AB P.O. Box 133 Tel. +46 506 48000 Internet: http://www.westerstrand.se E-mail: info@westerstrand.se SE-545 23 TÖREBODA Fax.
Document: 1717en21.doc MARINE MASTER CLOCK Author: PM Date: 2022-06-22 User Manual Page: 53 of 57 Fault tracing The display is blank The green LED “POWER” is light? A1A. Check the supply voltage. A1B. Power supply wires connected correctly? Yes. A2A. Restart the master clock by switching the supply voltage off and on.
Document: 1717en21.doc MARINE MASTER CLOCK Author: PM Date: 2022-06-22 User Manual Page: 54 of 57 “Exists” The signal point is already programmed. “Not programmed” When trying to change a non-existing signal point. Alarm output The Master Clock is equipped with two separate alarm relays. One relay for general alarm and one for power failure alarm.
Page 61
Document: 1785en03.doc INTELLIGENT CLOCKS Author.: TAn Date: 2009-11-04 Page: 1 of 5 WIRED DCF TIME CODE-CLOCK Max. 400 mm in diameter for Time zone adjustment TECHNICAL MANUAL WESTERSTRAND URFABRIK AB Box 133 Tel. 0506 48000 Internet: http://www.westerstrand.se 545 23 TÖREBODA Fax.
Page 62
Document: 1785en03.doc INTELLIGENT CLOCKS Author.: TAn Date: 2009-11-04 Page: 2 of 5 General Westerstrand analogue clock for wired DCF Time-Code from Marine Master Clock provides the possibility to create a time distribution system, with high accuracy and high reliability. The clock is intended for connection to a 2-wire bus which combines power supply and serial Time-Code A built-in microprocessor receives the Time Code, reads the position of the hands, and sets the clock to correct time.
Page 63
Document: 1785en03.doc INTELLIGENT CLOCKS Author.: TAn Date: 2009-11-04 Page: 3 of 5 Technical data Art.no 113160-20,113160-22.113163-20,113163-22 Connection 2-wire Connection voltage 24VDC combined with serial Time-Code Type of time code DCF-format with Time zone adjustment. PIC16F628 Microcontroller Temperature range -20 C to +50 C Power consumption 20 mA.
Page 67
Document: DOK11086en01 WESTERSTRAND Author: PM Date: 2021-06-16 Page: 2 of 22 List of contents List of contents ..................................2 General ..................................... 3 Technical data ..................................3 Configuration ..................................4 Setup IP ............................................... 4 Status IP .............................................. 5 Work mode (NTP Server or Client) ................................... 5 Configuration using a WEB browser ..........................
Document: DOK11086en01 WESTERSTRAND Author: PM Date: 2021-06-16 Page: 3 of 22 General The Ethernet module makes it possible to connect a Master Clock to a LAN (Ethernet Local Area Network). The module can be built into a Marine Master Clock. The module can be used for Master Clock remote control, programming of relay outputs, alarm distribution, supervision and for distribution of correct time.
Document: DOK11086en01 WESTERSTRAND Author: PM Date: 2021-06-16 Page: 4 of 22 Configuration Most of the configuration parameters are set via an external PC by using a Web-browser, but some of the settings can also be done from the Master Clock. The following parameters can be set from the Master Clock by using the special function setup.
Document: DOK11086en01 WESTERSTRAND Author: PM Date: 2021-06-16 Page: 5 of 22 Status IP Activity indicator 192.168.1.10 Present IP-address Work mode S = Server. The Master Clock works as a NTP time server. C = Client. The Master Clock works as a NTP time client.
Document: DOK11086en01 WESTERSTRAND Author: PM Date: 2021-06-16 Page: 6 of 22 Configuration using a WEB browser Login It is possible to login as administrator or guest. The administrator has the rights to read and to write/change configuration. A guest can read only. User name admin or guest.
Document: DOK11086en01 WESTERSTRAND Author: PM Date: 2021-06-16 Page: 7 of 22 Status Name Symbolic name of the Master Clock. This is set in function General. UTC/LT Current time, UTC and Local Time Timezone Time zone offset to UTC Shows the IP address of unit Netmask Shows the netmask setting Gateway...
Page 73
Document: DOK11086en01 WESTERSTRAND Author: PM Date: 2021-06-16 Page: 8 of 22 Synchronized: (192.168.3.7), Stratum=1, Answers=16 The Master Clock is synchronized and gets its time from an NTP server with IP address 192.168.3.7. This NTP server has stratum level 1 and the main clock has received responses to 16 NTP requests.
Document: DOK11086en01 WESTERSTRAND Author: PM Date: 2021-06-16 Page: 10 of 22 DHCP Use DHCP Unchecked – Static IP address according to static IP below. Checked – DHCP IP address with fallback according to IP fallback below. Fallback If DHCP is activated this will be the DHCP fallback address. Static IP Use static IP To be checked if static IP address is used.
Document: DOK11086en01 WESTERSTRAND Author: PM Date: 2021-06-16 Page: 11 of 22 Utilities Syslog Syslog server IP address. Send syslog messages if checked. Identity access Identify access is used in combination with application software Wunser. Wunser is a PC program that is used for finding and doing light configuration on Westerstrand Ethernet products. Firmware updates are also handled by Wunser.
Document: DOK11086en01 WESTERSTRAND Author: PM Date: 2021-06-16 Page: 12 of 22 Trap type This function is used to choose SNMP trap version. Trap type v1 = Trap according to SNMPv1 Trap type v2 = Trap according to SNMPv2 NTP settings General description Westerstrand NTP Servers has several features to achieve a reliable and accurate time service.
Document: DOK11086en01 WESTERSTRAND Author: PM Date: 2021-06-16 Page: 13 of 22 NTP mode This parameter defines if the unit shall work as an NTP Server only or both NTP Client and NTP Server. DHCP option 042 Ask for time using the server IP addresses received from the DHCP server (DHCP option 0042). Maximum 2 NTP servers are set automatically by option 0042.
Document: DOK11086en01 WESTERSTRAND Author: PM Date: 2021-06-16 Page: 14 of 22 NTP Advanced Advanced NTP settings Server mode With this function activated will the server broadcast/multicast NTP messages according to the chosen interval. The server will still answer NTP requests from NTP clients. Broadcast address: 255.255.255.255 Multicast address: 224.0.1.1 Interval(s)
Document: DOK11086en01 WESTERSTRAND Author: PM Date: 2021-06-16 Page: 15 of 22 Stratum when no external sync. With this function it is defined which stratum level the NTP server shall adopt when it has been synchronized but now is working standalone. Synchronized means that the master clock / time central has received correct time, either from an external sync source, GPS or similar, or that the time is set manually.
Page 81
Document: DOK11086en01 WESTERSTRAND Author: PM Date: 2021-06-16 Page: 16 of 22 Authentication If authentication is activated: Use MD5 authentication. Server ID/Key: Authentication data for the external NTP servers configured in the NTP server list. WESTERSTRAND URFABRIK AB P.O. Box 133 Tel.
Document: DOK11086en01 WESTERSTRAND Author: PM Date: 2021-06-16 Page: 18 of 22 General Used to configure general parameters. Name Symbolic name, maximum 64 characters. This name is shown in the status menu. Example: Central Master Clock ICC Password Login password. Admin = Adminstrator password. The administrator has the rights to read and to write/change configuration.
Document: DOK11086en01 WESTERSTRAND Author: PM Date: 2021-06-16 Page: 19 of 22 Lost password If the password has been lost network card has to be cold started (FULL RESET). Contact Westerstrand for details. Firmware Download Function to enable firmware download. See also section Firmware Download. Restart Restart the network card.
Document: DOK11086en01 WESTERSTRAND Author: PM Date: 2021-06-16 Page: 20 of 22 Firmware Download / Wunser General The Master Clock has support for firmware upgrade via the network. The utility program Wunser is used for firmware upgrade. Wunser can be downloaded from Westerstrand.se If checkbox Firmware Download is clicked, then the application jumps to a boot-loader.
Document: DOK11086en01 WESTERSTRAND Author: PM Date: 2021-06-16 Page: 21 of 22 Alarm The master clock is equipped with several supervision facilities to detect functional disturbances. Via the web browser status tab it is possible to see the Master Clock status including alarm (error) messages.
Page 87
Document: 1795en03.doc WESTERSTRAND Author: PM Date: May 8, 2014 Page: 22 of 22 CURRENT LOW 61 Red alarm LED lit. Impulse current Check the load on the impulse output. If OK, Alarm relay activated below alarm limit. check that the alarm limit is correctly SNMP trap sent configured.
Page 88
Document: DOK11018en02 WESTERSTRAND Author: PM/CF Date: 2020-09-24 Analogue NTP Clock Page: 1 of 21 Manual Analogue NTP Clock With Power-Over-Ethernet connection Contents General ............................................... 2 LAN connection ..........................................2 Functional description ....................................... 3 Installation ............................................3 Configuration using a WEB browser ................................. 4 Reset Button ..........................................
Document: DOK11018en02 WESTERSTRAND Author: PM/CF Date: 2020-09-24 Analogue NTP Clock Page: 2 of 21 General Westerstrand Analogue NTP Clock with Power over Ethernet (PoE) connection provides the possibility to create a time distribution system with high accuracy and high reliability. The NTP Clock is equipped with two motors, 3 hands analogue movement.
Document: DOK11018en02 WESTERSTRAND Author: PM/CF Date: 2020-09-24 Analogue NTP Clock Page: 3 of 21 Functional description After connection of the network cable, the hands are driven to 12:00. When the hands have reached this position, the motors will be stopped and the time code detector is switched on. The hands will not move until the time code has been accepted.
Document: DOK11018en02 WESTERSTRAND Author: PM/CF Date: 2020-09-24 Analogue NTP Clock Page: 4 of 21 Configuration using a WEB browser Login It is possible to login as administrator or guest. The administrator has the rights to read and to write/change configuration. A guest can read only. User name admin or guest.
Page 92
Document: DOK11018en02 WESTERSTRAND Author: PM/CF Date: 2020-09-24 Analogue NTP Clock Page: 5 of 21 Status Name Symbolic name. The name is set in function General UTC/LT Current time Timezone Offset to UTC during normal time (=winter time). The Clocks IP address Netmask Shows the netmask setting Gateway...
Page 93
Document: DOK11018en02 WESTERSTRAND Author: PM/CF Date: 2020-09-24 Analogue NTP Clock Page: 6 of 21 Synchronized = The clock has been synchronized from a NTP server with name/IP ntp.se s = Stratum, time quality. A low value is better n = Number of time settings from this NTP server TO= Timeout in minutes before NTP alarm.
Page 95
Document: DOK11018en02 WESTERSTRAND Author: PM/CF Date: 2020-09-24 Analogue NTP Clock Page: 8 of 21 DHCP Off – Static IP address according to static IP below. On – DHCP IP address with fallback according to IP fallback below. Fallback If DHCP is activated this will be the DHCP fallback address. Static IP To be checked if static IP address is used.
Page 96
Document: DOK11018en02 WESTERSTRAND Author: PM/CF Date: 2020-09-24 Analogue NTP Clock Page: 9 of 21 Use of secure communication protocol HTTPS (web-browser) if checked. SNMP This function is used to activate the SNMP, enter the address of one or more SNMP servers and to define the SNMP community.
Page 97
Document: DOK11018en02 WESTERSTRAND Author: PM/CF Date: 2020-09-24 Analogue NTP Clock Page: 10 of 21 NTP settings General description Westerstrand NTP Clients has several features to achieve a reliable and accurate time. The configuration of the different facilities is flexible and the features can be selected or deselected depending on each customer’s individual needs.
Page 98
Document: DOK11018en02 WESTERSTRAND Author: PM/CF Date: 2020-09-24 Analogue NTP Clock Page: 11 of 21 NTP settings DHCP option 042 Ask for time using the server IP addresses received from the DHCP server (DHCP option 0042). Maximum 2 NTP servers are set automatically by option 0042. Broadcast Broadcast: Accept broadcast/multicast time messages.
Page 99
Document: DOK11018en02 WESTERSTRAND Author: PM/CF Date: 2020-09-24 Analogue NTP Clock Page: 12 of 21 NTP server Select NTP servers, e.g. 192.168.1.237 or as an URL ntp.se. Also see =DHCP above Up NTP mode to five different NTP servers can be entered. If the first one fails it will automatically go to the next one and so on.
Page 100
Document: DOK11018en02 WESTERSTRAND Author: PM/CF Date: 2020-09-24 Analogue NTP Clock Page: 13 of 21 NTP advanced Advanced NTP settings Client mode FIRST. Always use the first server in the list if available. If not available take next one. This suits installations where it is more important to know exactly from where the clients get time than to have the most accurate time.
Page 101
Document: DOK11018en02 WESTERSTRAND Author: PM/CF Date: 2020-09-24 Analogue NTP Clock Page: 14 of 21 Authentication If authentication is activated: Use MD5 authentication. Server ID/Key: Authentication data for the external NTP servers configured in the NTP server list. WESTERSTRAND URFABRIK AB P.O.
Page 102
Document: DOK11018en02 WESTERSTRAND Author: PM/CF Date: 2020-09-24 Analogue NTP Clock Page: 15 of 21 Clock Used to configure general clock parameters. Double sided = Single sided Clock = Double sided Clock Second hand = No second hand = The clock has a second hand Reset hands This function will force the hands (pointers) to re-synchronize.
Page 103
Document: DOK11018en02 WESTERSTRAND Author: PM/CF Date: 2020-09-24 Analogue NTP Clock Page: 16 of 21 General Used to configure general parameters. Name Symbolic name, max. 64 signs. This name is shown in the status menu. Password Login password. Admin = Adminstrator password. The administrator has the rights to read and to write/change configuration. password Default password = nopassword...
Page 104
Document: DOK11018en02 WESTERSTRAND Author: PM/CF Date: 2020-09-24 Analogue NTP Clock Page: 17 of 21 Firmware Download Function to enable firmware download. See also section Firmware Download. Restart Restart the Clock. Backup/Restore Backup Save the clock configuration to a file. The clock suggests the Name field as filename (here NTP Clock.
Document: DOK11018en02 WESTERSTRAND Author: PM/CF Date: 2020-09-24 Analogue NTP Clock Page: 18 of 21 Firmware Download / Wunser General The Clock has support for firmware upgrade via the network. The utility program Wunser is used for firmware upgrade. Wunser can be downloaded using the following link: http://www.westerstrand.com/archives/download.htm If checkbox Firmware Download is clicked, then the application jumps to a boot-loader.
Page 106
Document: DOK11018en02 WESTERSTRAND Author: PM/CF Date: 2020-09-24 Analogue NTP Clock Page: 19 of 21 NETWORK INPUT/POE OUTPUT TO SLAVE SIDE (Double sided clock) STATUS DIODE LINK DIODE RESET BUTTON MAC-ADDRESS Terminal Description Remark Input for 10/100BASE-T. PoE 802.3af. Connector: RJ45 PoE consumption 2W max.
Document: DOK11018en02 WESTERSTRAND Author: PM/CF Date: 2020-09-24 Analogue NTP Clock Page: 20 of 21 Technical specification General Synchronization Accuracy 0,1 sec/24 h at 22 C (stand-alone mode) Hand movement Hour hand sweeping. Minute hand stepping, 6 steps/minute. Second hand sweeping. Time synchronization Total start-up time Maximum 10 min.
Document: DOK11018en02 WESTERSTRAND Author: PM/CF Date: 2020-09-24 Analogue NTP Clock Page: 21 of 21 Abbreviations Daylight Savings Time Local time Network Time Protocol Time code. The time message format transmitted to the movement Coordinated Universal Time WESTERSTRAND URFABRIK AB P.O. Box 133 Tel.
Page 109
Document: 9539en14.doc WESTERSTRAND Author: PM Date: 2018-08-15 Page: 1 av 5 Technical specification Marine Master clock General The master clock has 6 buttons and one (2 line x 16 character) LCD. To facilitate time zone change there are 2 separate buttons for this purpose. The master clock also has a dimmer to adjust background illumination.
Page 110
Document: 9539en14.doc WESTERSTRAND Author: PM Date: 2018-08-15 Page: 2 av 5 Outputs for slave movements *: Control clocks: Analogue display, with background illumination. Output 1: Impulse system: 1/1 minute, 1/2 minute, second, 1/2 second, time code (TC) Type of time: LT, UTC Impulse length: Minute 0.1-9.9 sec.
Page 111
Document: 9539en14.doc WESTERSTRAND Author: PM Date: 2018-08-15 Page: 3 av 5 Relay outputs Number of outputs: 2 Changeover potential-free contacts. Max load/relay output: 230 V 6A. Program memory: 100 year (EEPROM). Signal points: Special pulse output Relay output no. 2 can be dedicated to send out a special pulse. When this function is enabled the relay is activated every day for 5 seconds at 02.00 UTC.
Page 112
Document: 9539en14.doc WESTERSTRAND Author: PM Date: 2018-08-15 Page: 4 av 5 Serial ports The Master Clock is equipped with two serial ports, one RS232 and one RS422/485. Both ports can be used either as input or output for serial time messages.
Page 113
Document: 9539en14.doc WESTERSTRAND Author: PM Date: 2018-08-15 Page: 5 av 5 Power supply The master clock has two inputs for power supply, one for AC, and one for 24V DC. As standard the DC- input is a direct connected input without galvanic isolation and no compensation for low input voltage. With option DC/DC the DC-input will be galvanic isolated and low / high input voltage is compensated automatically.
Page 115
Calculation of Cable Area in Time Systems General To make a time system with impulse operated analog and digital slave clocks that performs satisfactorily, the cable from the Master Clock to the Slave Clocks needs to be dimensioned correctly. A 10% voltage drop is allowed in the cable. The length and area of the cable and the current (load) on the cable affect the voltage drop.
Page 118
Zenitel and its subsidiaries assume no responsibility for any errors that may appear in this publication, or for damages arising from the information therein. Vingtor-Stentofon products are developed and marketed by Zenitel. The company’s Quality Assurance System is certified to meet the requirements in NS-EN ISO 9001. Zenitel reserves the right to modify designs and alter specifications without notice.