Installation; Specifications - Sanyo HIT-N220E01 General Installation Manual

Advertisement

General Installation Manual

INSTALLATION

General
Please read this guide completely
before installation or use of the
modules.
This
section
electrical
and
specifications needed before using
your SANYO PV modules.
Modules should be firmly fixed in
place
in
a
manner
withstand
all
expected
including wind and snow loads.
Please do not touch the glass surface
of modules to protect from dirt,
because the glass surface is coated.
(If the glass surface becomes dirty,
see section of MAINTENANCE.)
The drilling and addition of ground
holes is permitted, but should be
avoided whenever possible to avoid
damage to the module.
additional
ground
necessary, they must not penetrate
the inner side of the aluminum frame.
Caution
is
advised
accidentally drilling, scratching, or
penetrating the back sheet surface of
the module.
If required, it is
recommended
to
add
ground holes to the outer aluminum
lip area of the module. In such case,
additional ground holes must be at
least 65 mm away from any frame
corner.
For a non-integral module or panel,
the assembly is to be mounted over a
fire resistant roof covering rated for
the application.
Appropriate material should be used
for mounting hardware to prevent the
module frame, mounting structure,
and hardware itself from corrosion.
Install modules where they are not
shaded by obstacles like buildings
and trees. Especially pay attention to
avoid partially shading the modules
by objects during the daytime.
Please
contact
your
Authorized
Representative
questions regarding mounting profiles
for modules if needed.
Notes on Installation
Clearance of "10 cm" between the
roof surface and module frame is
required to allow cooling air to
circulate around the back of the
module.
This
also
condensation or moisture to dissipate.
Install modules so that air can
circulate between the roof and the
module.
We recommend installation methods
shown in Figure 1. In some areas,
local electrical codes may govern the
installation and use of PV modules.
Operating Conditions
SANYO recommends that modules be
operated within the following Operating
Conditions. An installation location with
conditions
Conditions
contains
Conditions (see below) should be avoided.
mechanical
Operating Conditions of SANYO modules
are as follows:
1)
The modules should be operated only
in terrestrial applications. No space or
suitable
to
other Special Conditions (see below).
loads,
2)
The ambient temperature should be
within –20°C (-4°F) to 40°C (104°F).
3)
The relative humidity should be within
45% to 95%.
4)
The
wind pressure load of the
installation site should be less than
2,400N/m
Special Conditions
1)
The
ambient
When
installation place are different from
holes
are
the
Conditions.
2)
Salt
damage
to
avoid
installation place.
3)
Hail and snow damage is excessive
at the installation place.
additional
Installation (reference) – HIT-NxxxE01, NxxxE02
For questions regarding mounting profiles for modules, please contact your local dealer.
SANYO
with
Mounting
Structure Rail
allows
any
Spring washer
Flat washer
Flat washer
Spring washer
beyond
the
Operating
or
with
other
Special
2
(50PSF).
temperature
and
recommended
Operating
is
severe
at
the
M6 Nut
M6 Bolt
Section A-A
Figure 1: Installation
2
4)
Sand and dust damage is excessive
at the installation place.
5)
Air pollution, chemically active vapors,
acid rain, and/or soot, etc. are
excessive at the installation place.

SPECIFICATIONS

Notes on Specifications
1)
Rated electrical characteristics are
within 10% of the values measured at
Standard
Test
Conditions
Irradiance of 1000W/m
temperature,
and
solar
irradiance per IEC 60904-3.
2)
Under
normal
conditions,
photovoltaic module may experience
conditions that produce more current
and/or
voltage
than
standard component test conditions.
Accordingly, the values of Isc and
Voc should be multiplied by a factor
of 1.25 when
determining voltage
ratings, conductor capacities, fuse
sizes, and size of controls connected
to the module output.
3)
The current output for the modules
shown
in
the
Specifications
measured
at
Standard
Conditions.
These conditions may
Solar Module
A
A
Solar Module
Module
Mounting Structure Rail
(STC).
2
o
, 25
C cell
spectral
a
reported
at
is
Test