VMAC will not be held responsible for any liability, consequential damages, injuries, loss or damage to individuals or to equipment as a result of the failure of anyone to properly adhere to the procedures set out in this manual or standard safety practices.
Warranty registration for VMAC systems can be completed online or by filling in the form at the back of each system installation manual. Warranty registration must be completed and sent to VMAC at the time the system is put into service for any subsequent warranty claim to be considered valid.
Page 7
If requested, failed parts must be returned to VMAC for evaluation. 4) Dealers may login to the VMAC website to view the "VMAC Labour Time Guide" (under “Agreements”) to see the allowable warranty labour times. 5) Warranty invoices must include the Service Ticket number, VMAC System ID#, hours on the compressor, and a detailed description of the work performed.
Please contact VMAC for replacement hoses and further information. Ordering Parts To order parts, contact a VMAC dealer. The dealer will ask for the VMAC serial number, part number, description and quantity. Locate the nearest dealer online at www.vmacair.com/dealer-locator or call 1-877-912-6605.
Page 9
All fasteners must be torqued to specifications. Use manufacturers’ torque values for OEM fasteners. The torque values supplied in Table 1 are intended for VMAC supplied components, or for use as a guide in the absence of a torque value provided by an OEM.
Error Weld alarm light Weld interlock Reset On/Off Voltmeter button button Figure 1 — Remote generator control box with Voltage Sense Interlock VMAC - Vehicle Mounted Air Compressors VMAC Technical Support: 888-241-2289 VMAC Knowledge Base: kb.vmacair.com...
Page 11
With the battery connected, rotate the “WELD” selection knob to the appropriate charge mode*. ☐ *The voltage should rise as the system begins charging. ☐ Set the “WELDING CURRENT” knob to 100%. VMAC - Vehicle Mounted Air Compressors VMAC Technical Support: 888-241-2289 VMAC Knowledge Base: kb.vmacair.com...
Page 12
*If using the Current Control Pendant, disconnect it. ☐ *Set the “WELD” selection knob to 0 V (The “WELD INTERLOCK” button is not required when returning the “WELD” selection knob to 0 V). VMAC - Vehicle Mounted Air Compressors VMAC Technical Support: 888-241-2289 VMAC Knowledge Base: kb.vmacair.com...
System will boost for repeated until battery 60s and re-measure voltage is greater than battery voltage 2V for 12V battery or greater than 14V for 24V battery REV005 VMAC - Vehicle Mounted Air Compressors VMAC Technical Support: 888-241-2289 VMAC Knowledge Base: kb.vmacair.com...
Return the “WELD” selection knob to 0 V. ☐ Press and hold the “RESET” button for 2 seconds. ☐ If the error persists, contact VMAC for support. Error Description Corrective Action Gas MF output voltage is greater than 20 V (12 V boost mode) or 38 V (24 V boost mode).