Mark holes
1 Select the vent option that your installation will require and
proceed to that section:
Outside top exhaust
(Vertical duct– 3
"x 10" Rectangular)
1
4
Use the diagram or the hood as a template and mark the locations
on the cabinet for ductwork, electrical wiring and keyhole screw
slots.
Hood mounting screws (4)
13
" (30" hood)
15
1 6
16
" (36" Hood)
15
1 6
Cabinet front
Cabinet bottom
5"
1
"
1
4
Wood shims (recessed
bottom cabinets only)
Outside top exhaust (Only recirculating version)
(Vertical duct–7" Round)
Use the diagram or the hood as a template and mark the locations
on the cabinet for ductwork, electrical wiring and keyhole screw
slots.
Hood mounting screws (4)
13
" (30" hood)
15
16
16
" (36" Hood)
15
16
Cabinet front
Cabinet bottom
Access hole for
7" round duct
Wood shims (recessed
bottom cabinets only)
Outside rear exhaust
(Horizontal duct– 3
"x 10" Rectangular)
1
4
Use the diagram or the hood as a template and mark the locations
on the cabinet for ductwork, electrical wiring and keyhole screw
slots.
Cabinet front
3
"
Horizontal duct
3
4
Cabinet
5
bottom
13
" (30" hood)
15
16
16
" (36" Hood)
15
16
Hood mounting
screws (4)
8
13
" (30" hood)
15
1 6
16
" (36" Hood)
15
1 6
12
"
1
2
5
"
5
"
1
1
4
4
1
"
1
4
Vertical duct
access hole
Centerline
Electrical access
hole (in cabinet
bottom)
13
" (30" hood)
15
16
16
" (36" Hood)
15
16
12
"
1
2
HOLE
1
"
1
4
8" DIA.
5"
Electrical access hole
Centerline
(in cabinet bottom)
"
1
"
1
9
8
16
access hole
"5
"
1
1
4
4
12
"
7
16
13
" (30" hood)
15
16
16
" (36" Hood)
15
16
Electrical access hole
Centerline
(in wall)
Installation- Recirculating
Use the hood as a template and mark the locations on the cabinet
for the electrical wiring and keyhole screw slots.
Since the hood is to be recirculated (not to be vented outside), do
not cut out any vent openings in the wall or cabinet bottom.
Choose Venting Option
1 The hood can be set to vent outside or to recirculate air back
into the kitchen. The plastic vent lever is located near the
center of the hood opening.
To vent to the outside, make sure the plastic vent lever is in
the HORIZONTAL position (flat against the metal top of the
hood). To recirculate air into the kitchen, make sure the plastic
vent lever is in the VERTICAL position (flat against the plastic
blower housing).
NOTE: In order to change the vent lever position, you will need
to pull the lever out slightly to clear the plastic tabs.
10
"
1
2
1
"
1
2
10
"
1
2
For recessed bottom cabinet only
1
"
1 If the cabinets have front, side or back trim, make 2 wood
1
2
shims the width of the trim and attach them to the cabinet
bottom recess on both sides.
See previous page for marking locations.
2 Cut holes at marked locations for duct and electrical wiring.
For the vertical duct, cut out 3⁄4" extra toward the front of the
cabinet so you can move the duct freely when installing the
hood. It may also ease installation by cutting the hole 10
instead of 10".
3 Drive a mounting screw (from the hardware packet) partway
into each center of the narrow neck of the keyhole slots
marked on the cabinet bottom.
4 Fix the wiring conduit to the hood.
5 Slide the hood back against the wall. Tighten the mounting
screws. Be sure the screw heads are in the narrow neck of the
keyhole slot. Connect Ductwork to hood.
Set for
Set for
outside venting
recirculating
Stop tab
Stop tab
Hood shown lying upside down
Wood shims
"
1
2

Advertisement

Table of Contents