RESEARCH CONCEPTS RC2K90INT-1 Manual page 22

Rc2000 antenna interface box
Table of Contents

Advertisement

Description of
Conduit Run
Conduit Run
Starting Point
and Conduit
Fitting Type
Azimuth Limit
Azimuth Sensor,
Switch
90 Degree Fitting
Elevation Sensor
Interface Box,
Straight Fitting
Elevation Limit
Elevation Sensor,
Switch
Straight Fitting
Elevation Motor
Interface Box,
Straight Fitting
The antenna will be shipped with four flexible conduit runs (with wire pulled through the conduit) to the
elevation motor, elevation sensor, azimuth sensor, and azimuth motor attached to the interface box. The
installer will have to attach these conduit runs to the elevation motor, elevation sensor, azimuth sensor, and
azimuth motor. The two other conduit runs (elevation sensor to elevation limit switch conduit run and the
azimuth sensor to the azimuth limit switch conduit run) will be included with the interface box but not
attached to anything - the installer will have to place these. The Teflon tape included with the installation
kit can be used on any conduit fitting which cannot accept a sealing gasket or O ring (such as the 1/2" to
3/4" bushing used on the limit switches).
Once the conduit has been attached the wiring connections can be made.
The installer must make the following connections (please refer to figures P1 and P2).
1. The RC2000 to Interface Box Interconnect cable must be installed. Make the connections at the
RC2000. Refer to Chapter 3 in the RC2000 manual for more information on the connection at the
RC2000.
2. The motor control signals on the RC2000 to Interface Box interconnect cable must be attached to the
AZ1_CTL, AZ2_CTL, EL1_CTL, and EL2_CTL terminals on the circuit board in the interface box.
3. The sensor cables in the RC2000 to Interface Box interconnect cable will have to be spliced to the
Belden 8772 cable in the interface box. Please reread section 3 of this manual and refer to figure 7 in
the RC2K90INT-1 interface box manual before making the splice. Use the 3M Scotchlok connectors
to make the splice. Proper connection of the sensors is critical to the operation of the antenna
controller.
4. Connect the sensor cables to the sensors (refer to figure P1). At the sensors, cut off the drain wire and
place a piece of heat shrink tubing over the sensor cable where the insulation is cut so that the shield
Prodelin 3.8m Antenna Installation Kit
Conduit Length
Cable
Type/Length
31 Inches
The Continuation
of the 18/2 Cable
Described in the
Previous Entry.
120 Inches
18/2 - 160 Inches,
Belden 8772 - 130
Inches
12 1/2 Inches
The Continuation
of the 18/2 Cable
Described in the
Previous Entry
105 Inches
16/3 - 120 Inches
22
Conduit Run
Termination
Point and Fitting
Type
Azimuth Limit
Switch, Straight
Fitting. Note: A
1/2" to 3/4"
Conduit Bushing is
Required at the
Limit Switch
Elevation Sensor,
90 Degree Fitting
Elevation Limit
Switch, 90 Degree
Fitting. Note: A
1/2" to 3/4"
Conduit Bushing is
Required at the
Limit Switch
Elevation Motor,
90 Degree Fitting

Advertisement

Table of Contents
loading