Data Rebuilding Operation - Raidon InTANK iR2823 User Manual

Hide thumbs Also See for InTANK iR2823:
Table of Contents

Advertisement

iR2823 / iR2824 User Manual

8. Data Rebuilding Operation

The Hot Swappable hard drive and Auto Rebuilding features are available.
Off-line Back up:When the data is stored in iR2823/IR2824, user can remove one of the hard drives
as back up drive for data such as system operation file, secured files, seldom modified files or image
and music files. The user can periodically insert the hard drive back into iR2823 / iR2824 to execute
automatic backup to protect the system from being hit by computer virus or to avoid the risk of having
both hard drives failing at the same time.
When one of the two hard drives fails in iR2823/IR2824, it will issue an alert of a hard drive failure
message in both LCD display and the monitoring software. User can remove the failed hard drive
from the system while the system is still in operation without shutting down the machine. If the failed
hard drive is replaced shortly, the system will automatically execute the Auto Rebuilding function
without affecting the system operation and also any operation command from the user.
When the iR2823 / iR2824 detects one hard drive missing or failure, the Buzzer starts BEEPING and
the LCD displays the following messages:
After replacing a new hard disk with the failed one, LCD displays the following messages:
Pri HDD : OK
Sec HDD : Insert
After few seconds from your inserting a new hard drive, LCD displays the data rebuilding progress:
Rebuilding
Sec → Pri 32%
When iR2823 / iR2824 completes its rebuilding, LCD again displays the following messages:
RAID-1 degraded
Pri : X Sec : O
Pri HDD : OK
Sec HDD : OK
7
Pri HDD :Insert
Sec HDD : OK
Rebuilding
Pri → Sec 32%

Advertisement

Table of Contents
loading

This manual is also suitable for:

Intank ir2824

Table of Contents