Lutron Electronics FS-SE Quick Start Manual
Lutron Electronics FS-SE Quick Start Manual

Lutron Electronics FS-SE Quick Start Manual

Fan/light controls

Advertisement

Available languages

Available languages

Quick Links

adjust minimum
speed (refer to
instructions on
front of control).
Trimpel
locetlon
GFS-sE
Trimpet
locetlon
up to decrease
minimum speed
• Easy-to-follow
Instructions
• Instructions
(aciles
a
suivre
PIN 033-{)43
£to-8£O Nld
fJJAJns , sfJl!:JeJ
SUO!I:JnJISUI •
sUOn:mJISUI
MOlloJ-ob~se3
Fan/Light Controls
Rated at 120VAC, 60Hz
FS-SE:
SA maximum
SFS-SE:
SA maximum
GFS-SE: SA maximum
SFS-SEA: SA maximum
SFSQ-LF: Fan: I.SA, Light 360W
Important Notes
1. CAUTION: To avoid overheating and possible damage to other
equipment, do not use to control receptacles, fluorescent lighting
fixtures, or transformer-supplied appliances.
2. Controls require separate wires in the wall box for fan and light.
3. For new installations, wire a test switch before installing the control.
4. Set multispeed fans to their highest setting before installing controls.
5. Use SFSQ-LF control with a ceiling paddle fan only. Use only one
ceiling paddle fan per control.
6. Use FS-5E, GFS-5E, SFS-5E and SFS-5EA controls only with fans
marked "Suitable for use with solid-state fan-speed controls."
7. Do not wire an SFSQ-LF in circuit with a GFCI breaker/receptacle.
S. Controls may feel warm to the touch during normal operation.
9. If a bare copper or green ground connection is not available in the
wallbox, contact a licensed electrician for installation.
10. Install in accordance with all national and local electrical codes.
Multi-Unit Installations
When combining controls in a wall box, remove all inner side sections
before wiring (see below). Use pliers to bend each side section up and
down until it breaks off. SF-5E, GFS-5E, SFS-5E and SFS-5EA controls
require reduction of their capacity. Refer to chart below for maximum
capacity. SFSQ-LF controls do not require capacity reduction.
Remove alllnnsr
slda sections
(shaded).
Do not remove
~
outar slda
sections.
No Sides
Model Number
Removed
All except SFSQ-LF
SA'
1 Side
2 Sides
Removed
4A'
Removed
3A'
'Combined maximum for fan and light
Technical Assistance
If you have questions concerning the installation or operation of this
product, call the Lutron Technical Assistance Hotline. Please provide
exact model number when calling.
(800) 523-9466 (U.S.A., Canada, and the Caribbean)
Other countries call (610) 282-3800
Fax (610) 282-3090
warranty
Lutron will, at its optIOn, repair or replece any unillhat is defective in materials or manufacture within one year
after purchase. For warranty service, return unit to place of purchase or mail to Lutron 817200 Suter Rd.,
Coopersburg, PA 18036-1299, postage prepaid.
This warranty IS
In
lieu 01 all other warranties, express or implied. and the implied warranty 01 merchentability is
limited to one year from purchese. This werranty does not cover the cost 01 installation, removal or
reinstallation, or damage resulting from misuse, ebuse, or damage from improper wiring or installation. This
warranty does not cover incidental or consequential damages.
Thie warrenty giVes you specific legal rights, end you may have other tights which vary from state to state.
Some etetes do not allow the exclusion or limitation 01 incidental or consequential damages, or limitation on
how long an implied warranty may last. so the ebove limitations may not apply to you.
This product may be covered by Mexicen patent 168,884 end one or more 01 the following U.S, patents:
4,833,277; 4,835,343: 4.835,816; 5.191,971; 5,262,678; 5,293,103; 5,359.231; DES 342,234 and
corresponding foreign patents. Lutron
IS
a registered trademark of Lutron Electronics Co., Inc.
@
1998 Lutton Electronics Co., Inc.
Installation
For installations involving more than one control in a wallbox, refer to
Multi-Unit Installations before beginning.
~1i§ii
WARNING: Turn power OFF at circuit breaker or remove
fuse.
;~Ht:~~·~··
....
··t:::I·l
_ ..
f 8tIDIIII·~IiiiiI·'·<:
61
Remove switch mounting screws. Pull switch from wall.
f"l@'ilCJ
Verify application. This dimmer mounts in a Single-gang
wallbox and independently controls a ceiling paddle fan and
a light with each slider. Independent wire must be provided
for the fan and light in addition to the feed wire (Hot).
Tag the wire that is connected to the feed side of the
switch (the side with the break-off fin).
Food (Hot)
~1fIiI1
Disconnect switch wires.
,(
J
Turn screws to loosen.
When making wire connections, twist and
_~
trim all wires to the proper length as
/8"-&
' " "' I IlIIi
indicated:
318"
'or
14, 16,
or
18
gauge
Nole:
Wire connectors provided are suitable
for copper wire only. For aluminum wire,
1\
/
consult an electrician. Use connectors to join
( r-
one
14
gauge supply wire with one
18
gauge
control wire.
fjWil!l
Wire the control.
Hot
120V
60Hz
Ground
*Csp offYellowwlrv If no light is used,
Red*
Light
f1lii'!
Mount and align control. Install wall plate.
Align control and
tighten screws,
f1PC'l
Turn power ON.
Setting minimum fan speed
Turn the control ON to its lowest level as follows: FS-5E: turn knob
fully clockwise. GFS-5E, SFS-5E, and SFS-5EA: lower knob to the point
just before it clicks off. Wait two minutes.
If
the fan stops, adjust its
minimum speed: turn trimpot or thumbwheel (see below) until fan turns
on to desired speed. Not required for SFSQ-LF.
Use s
small
.A.-,
SFS-sE & SF5-sEA
screwdriver to
Rotate thumbwheel
FS-sE
down to increase or
(refer 10 instructions
on front of control).
Ek:
• Connect the green or bare
ground wire on the control (if
present) to the green or bare
copper ground wire in the
wallbox.
• Connect the black wire on the
control to the tagged wall box
wire removed from the switch
(feed wire from the circuit
breaker or fuse box).
• Connect the red wire on the
control to the wire leading to the
fan.
• Connect the yellow wire on the
control to the wire leading to the
light.
Lutron Electronics Co., Inc,
7200 Suter Aoad
LUTRON®
Franfais au verso
Coopersburg, PA 18036-1299, U.S.A.
Made and printed in U.S.A. 2/98 PIN 033-043 Rev. A

Advertisement

loading

This manual is also suitable for:

Gfs-seSfs-seSfs-seaSfsq-lf