Summary of Contents for Cleva VK811SIWD

  • Page 1 Wet/Dry Vacuums Owner’s Manual This unit is intended for commercial use. 8 Gallon Industrial (Commercial) Wet/Dry Vacuum Model No. VK811SIWD FOR YOUR SAFETY Read and understand this manual before use. Keep this manual for future reference. www.cleva-na.com Cleva North America, Inc.
  • Page 2: Warranty

    / invoice will act as proof of purchase. Contact Cleva at 866-384-8432 for any warranty inquiries. Do not return a failed unit to the place of purchase or service center. Any charges for the shipping of a Cleva unit under warranty are purchaser’s responsibility unless Cleva requests such return in writing.
  • Page 3: Safety Instructions And Warnings

    Safety is a combination of common sense, staying alert and knowing how your vacuum works. Use this Wet/Dry Vac only as described in this manual. To reduce the risk of personal injury or damage to your Vac, use only CLEVA recommended accessories. For commercial use, SAVE THIS MANUAL FOR FUTURE REFERENCE.
  • Page 4: Double Insulation Instructions

    DOUBLE INSULATION INSTRUCTIONS This Wet/Dry Vac is double-insulated, eliminating the need for a separate grounding system. Use only identical replacements parts. Read the instructions for Servicing Double-Insulated Wet/Dry Vacs before servicing. Use this Wet/Dry Vac as described in this manual. Observe the following warnings that appear on the motor housing of your Wet/Dry Vac.
  • Page 5: Extension Cords

    EXTENSION CORDS When using an extension cord with your Wet/Dry Vac refer to the following table to determine the required A.W.G. wire size. Before using the cleaner make sure the power cord and extension cord are in good working conditions. Make repairs or replacements before using the vacuum cleaner. Only use extension cords that are rated for outdoor use.
  • Page 6 UNPACKING AND CHECKING CARTON CONTENTS Remove entire contents of carton. Check each item against the carton contents list. Carton contents lists Description……………………..…… QTY. Vac Assembly…………………….……. Crevice Nozzle……….…………..Extension Wands (1)…………..... Extension Wands (2)…..…………..Air Regulator Handle…………..... Hose…………………….…....Floor Squeegee………………………... Horse Hair Round Brush…..….... Accessory Adaptor…..………………...
  • Page 7 GENERAL ASSEMBLY INSTRUCTIONS A Philips head screw driver is required. WARNING: DO NOT PLUG IN POWER CORD TO POWER OUTLET, MAKE SURE PLUG IS DISCONNECTED BEFORE ASSEMBLING THE WET/DRY VAC. UNPACKING YOUR WET/DRY VACUUM & GENERAL ASSEMBLY 1. Verify that the power cord is disconnected from the outlet. (fig. 1) 2.
  • Page 8: Dry-Vacuum Operation

    LIGHTED PLUG This vacuum comes standard with a lighted plug that when plugged in lights up showing user that wall receptacle is working and that vacuum has power. DRY-VACUUM OPERATION DRY VACUUM WARNING: BE SURE TO READ, UNDERSTAND, AND APPLY INFORMATION, ENTITLED ‘SAFETY INSTRUCTIONS &...
  • Page 9 OPERATING INSTRUCTIONS: DRY VACUUMING 1. Insert the locking end of the hose into the vacuum port and lock in place. Push the required attachment onto the free end of the hose or extension. (fig. 6) 2. Plug in the power cord into the outlet. (fig. 7) 3.
  • Page 10: Liquid Vacuum Operation

    LIQUID VACUUM OPERATION LIQUID VACUUMING NOTE: This vacuum comes equipped with a washable cartridge filter capable of being used for wet pick-up. However, if the washable cartridge if full of dirt, it is better to remove it and use the supplied foam filter.
  • Page 11: Maintenance

    IMPORTANT! When vacuuming large quantities of liquids, do not immerse the nozzle completely in the liquid; leave a gap at the tip of the nozzle opening to allow air inflow. The machine is fitted with a float valve that stops the suction action when the container reaches its maximum capacity.
  • Page 12: Installing & Cleaning Foam Sleeve Filter

    Installing Cartridge Filter 1. Verify that the power cord is disconnected from the outlet. (fig. 1) 2. Remove power head and place in upside down position. 3. Install the cartridge filter over the filter cage and carefully push filter in until it stops against the power head.
  • Page 13: When To Change Filters

    WHEN TO CHANGE FILTERS Change the collection bag When the collection bag is 3/4 full, it MUST be replaced. Excessive over filling of this bag makes it difficult to remove from the vacuum tank and can result in breakage and spills. When collection bag becomes 3/4 full, turn off vacuum and slowly remove the collection bag from the tank until the opening in the collection bag is clear of the tank.
  • Page 14: Parts -Exploded View

    PARTS -EXPLODED VIEW VK811SIWD Manual Parts List Key Number Drawing Number Description Quantity Key Number Drawing Number Description Quantity VK01SR.A0.01 Handle FV5943.01.20 Extension Wands (1) Power Head FV5943.01.01 Extension Wands (2) VK35SR.10.00 Float Air Regulator Handle TVQTZS.03.YZ FV5943.01.10 Filter Cage Adaptor For Power Tools VI02SR.10.06...
  • Page 15 NOTES...