Cleaning The Inlet Hose And The Valve Filter; Frost Precautions; Troubleshooting - Zanussi ZWF 61400W User Manual

Table of Contents

Advertisement

Available languages

Available languages

CLEANING THE INLET HOSE AND THE VALVE FILTER

1
1
2
3

FROST PRECAUTIONS

If the appliance is installed in an area where the
temperature can be less than 0 °C, remove the
remaining water from the inlet hose and the drain
pump.
Do this procedure also when you want
to do the emergency drain.
1. Disconnect the mains plug from the mains
socket.
2. Remove the water inlet hose.
3. Remove the drain hose from the rear support
and unhook it from sink or spigot.
4. Put the ends of the drain and inlet hose in a
container. Let the water flow out of the hoses.

TROUBLESHOOTING

WARNING! Refer to Safety chapters.
INTRODUCTION
The start of the appliance does not occur or it
stops during operation.
First try to find a solution to the problem (refer to
the table). If not, contact the Authorised Service
Centre.
With some problems, the acoustic signals operate.
The red indicator of the button Start/Pauze Départ/
Pause flashes and one of the phase indicators
comes on, to show an alarm code:
14
2
3
5. When no more water flows, install the inlet
hose and the drain hose again.
WARNING! Make sure that the
temperature is more than 0 °C before
you use the appliance again. The
manufacturer is not responsible for
damages caused by low temperatures.
- The appliance does not fill with water
properly.
- The appliance does not drain the water.
- The appliance door is open or not closed
correctly. Please check the door!
The indicator of button Start/Pauze Départ/
Pause flashes in red 11 times and 1 (or 2 or 3)
time(s) in green: the mains supply is unstable.
Wait until the mains supply is stable and the
appliance automatically starts operating.
WARNING! Deactivate the appliance
before you do the checks.