CAUTION: Read all instructions before using the unit.
®
START/S TOP
PROGRA M
DOWN
UP
POW ER
P/N 1010678 Rev. O 04/21

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DFW Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Antunes DFW Series

  • Page 1 ® START/S TOP PROGRA M DOWN POW ER DFW Series Deluxe Food Warmer Owner’s Manual Manufacturing Numbers: 9100101, 9100102, 9100103, 9100104, 9100105, 9100106, 9100107, 9100110, 9100111, 9100112, 9100113, 9100114, 9100115, 9100116, 9100117, 9100118, 9100121, 9100122, 9100123, 9100124, 9100125, 9100126, 9100127, 9100128,...
  • Page 2: Table Of Contents

    Wiring Diagram 1 ........22 Wiring Diagram 2 ........23 Limited Warranty ........24 IMPORTANT IMPORTANT Antunes reserves the right to change Keep these instructions for future specifications and product design reference. If the unit changes ownership, without notice. Such revisions do not...
  • Page 3: Important Safety Information

    If a chemical cleaner is used, stainless steel equipment. The only. Contact Antunes Technical be sure it is safe to use on cast damage is usually in the form Service for adjustment or repair.
  • Page 4: Specifications

    2800 12.2 50/60 Capacities 9100128 16 Amp. 250 Volt DFWT-200 NEMA 5-15P DFW Series 2-7/8” (7.3 cm) Deep Half-size steam table pan 1800 50/60 9100131 15 Amp, 120 Volt DFWT Series 2-7/8” (7.3 cm) Deep Two-third-size steam DFWT-200 NEMA 5-20P...
  • Page 5: Installation

    NOTE: If any parts are missing or dam- Water Pressure Regulator Inlet Hose & Strainer & Strainer Assy. (P/N 7000314) aged, contact Antunes Techni- Assy. (Supplied) cal Service IMMEDIATELY at Figure 1. Connecting Water Supply to DFW/DFWT/DFWF-200/250 1-877-392-7854 or 1-630-784- 1000.
  • Page 6: General Information

    General Information WARNING All models To avoid injury, be careful when open- ing top cover. Be sure to allow steam When the OPERATE button is pressed, to escape before putting hands or power is supplied to the water pump face over the steamer. (Water Tank models) or solenoid valve (Direct Water Hookup models).
  • Page 7: Programming

    Programming To program the control, refer to Figure Press and release the Program button again and use the UP or DOWN arrow 4 and use the following procedure in CYC (Total Cycle Time) refers to the buttons to change the SHO setting in sequence: total amount of steaming time set for the minutes (Item F, Figure 4).
  • Page 8: Safety Features

    100k ohms +/- 2% at Turn the power off. If the unit requires continuous resetting, room temperature. contact Antunes Technical Service. Press and hold the PROGRAM and NOTE: The unit will not call for heat. START/STOP buttons simultaneously.
  • Page 9: Daily Maintenance

    CAUTION Trivet Cover Assy. Do not use a sanitizing solution or abrasive materials. The use of these may cause dam- age to the stainless steel finish. Gasket CAUTION Hinge Pin If a chemical cleaner is used, be sure it is safe to use on cast aluminum.
  • Page 10: Water Tank Filte

    Monthly Maintenance Water Tank Filter Tank Cover (Continued) Filter Stem Bottom Hole Water Tank Filter of Water (DFW/DFWT-100/150 only) Tank Access The water tank filter is used to prevent Cover particles or food products from entering with Tank and damaging the water pump. Inspect (dotted line) and clean this filter monthly or more regu- larly using the following procedure.
  • Page 11: Troubleshooting

    The unit should be unplugged when servicing, except when electrical tests are required. Use extreme care during electrical circuit tests. Live circuits will be exposed. If the troubleshooting steps listed below do not solve your machine’s problem, contact Antunes Technical Service for further assistance. Problem...
  • Page 12 Troubleshooting (continued) Problem Possible Cause Corrective Action Unit heats but there is little or no Water Line Valve is closed (DFW/DFWT/ Check that the Water Line Valve is open. steam produced and/or DFWF-200/250). The product requires more steam- Filter Strainer and/or Spray Tube is restricted. Check and clean the Filter Strainer and Spray ing than usual.
  • Page 13 Valve and clean out the plunger. Reassemble the unit and test again. If a leak is still pres- ent, replace the Solenoid Valve. Contact your maintenance person or Antunes Technical Service. The Water Pump and/or its Check Valves are Verify that the filter is present in the water clogged or damaged.
  • Page 14: Cooking Guide

    Cooking Guide Use the suggested cooking times below Product Minutes Product Minutes on noodles, rice, cereals, breads, meat, Meat Vegetables seafood, poultry, eggs, and vegetables, or experiment with your own products and Bratwurst, 6 (4 oz. ea.) Artichokes, 4 Whole (5 oz. ea.) 20-22 steaming times.
  • Page 15: Replacement Parts

    Replacement Parts Water Pressure Regulator Kit Item Dual Water Pressure Regulator Kit - Part No. 7000235 Part # Description Qty. To Steamer Elbow, Quick Disconnect To Steamer 2080105 - 1/4” Tubing 1/4” I.D. PVC 2030126 BRD. 24” Long Tubing 1/4” I.D. PVC 2030125 BRD.
  • Page 16: Replacement Parts List

    Spray Tube Assy. (DFW) 7000135 Hi-Limit Thermostat 0010146 Spray Tube Assy. (DFWT) 7000136 Terminal Block Kit (Incl. No. 43) Steam Generator, 120V (DFW Series) 1800 100P967* Marking Label 7000124 Watts 7000137 Water Pump Kit, 24 VAC (Incl. No. 32 & 33) Steam Generator, 120V (Mfg.
  • Page 17: Exploded Diagram 1

    Replacement Parts (DFW/DFWT-100/150) Exploded Diagram 1 Inset A - Parts are used on DFWT-150 with manufacturing number 9100128 only. See Inset A Inset B Inset C (Non-Timer) Models DFW/DFWT-100 See Inset B NE S AN TU IN US MA DE R1 8 See Inset C SE RI...
  • Page 18: Replacement Parts List

    7000136 Terminal Block Kit (Incl. No. 43) 0010146 Spray Tube Assy. (DFWT) 100P967* Marking Label Steam Generator, 120V (DFW Series) 1800 7000137 Water Pump Kit, 24 VAC (Incl. No. 32 & 33) 7000124 Watts 7000142 Outlet Tube Kit (Incl. Nos. 46, 47 & 48) Steam Generator, 120V (Mfg.
  • Page 19: Exploded Diagram 1

    Replacement Parts (DFW/DFWT-200/250) Exploded Diagram 1 See Page 15 for Strainer Parts Inset B Inset C (Non-Timer) See Inset B Models DFW/DFWT-200 See Inset C Inset C Timer Models DFW/DFWT-250 P/N 1010678 Rev. O 04/21 ®...
  • Page 20: Replacement Parts List

    Replacement Parts List DFWF-250 ONLY Item Item Part # Description Qty. Part # Description Qty. 0011165 Top Cover Assy. (Incl. Items 2, 3, & 4) Control Board (Non-Timer Models)(Mfg. 7000392 No. 9100147) 0020769 Top Cover Shell 7000319 Transformer 0021094 Top Cover Liner 7000652 Solid State Relay 7000140 Top Cover Gasket Kit 0010584 Inlet House Assy.
  • Page 21: Exploded Diagram 1

    Replacement Parts (DFWF-250 ONLY) Exploded Diagram 1 Inset A Inset B Non-Timer Model Timer Model Mfg. No. 9100147 only See Page 25 See Inset B for Strainer Parts 9 (See Page 5) Inset A P/N 1010678 Rev. O 04/21 ®...
  • Page 22: Wiring Diagram 1

    Wiring Diagram 1 DFW/DFWT/DFWF-150/250 Only Timer Models Only - Except DFWF-250 units with Mfg. No. 9100147 POWER WIRING DIAGRAM CORD NOTE: ALL WIRES TO BE 14 GA. AWM-105°C UNLESS OTHERWISE SPECIFIED. # 18 GA. AWM-105°C 22 GA. AWM-105°C MOMENTARY THERMOCOUPLE SWITCH TERMINAL BLOCK...
  • Page 23: Wiring Diagram 2

    Wiring Diagram 2 DFW/DFWT-100/200 and DFWF-250 Models with Mfg. No. 9100147 Only. Timer Models Only. WIRING DIAGRAM POWER NOTE: ALL WIRES TO BE 14 GA. AWM-105°C CORD UNLESS OTHERWISE SPECIFIED. # 18 GA. AWM-105°C 22 GA. AWM-105°C THERMISTOR S.S. RELAY TERMINAL BLOCK HEATER...
  • Page 24: Limited Warranty

    Antunes reserves the right to make changes in design or add any improvements on any product. The right is always reserved to modify equipment because of factors beyond our control and government regulations. Changes to update equipment do not constitute a warranty charge.