Antunes DCH-320 SQ Owner's Manual

Display cabinet heated

Advertisement

Quick Links

®
DCH-320 SQ
Display Cabinet Heated
Owner's Manual
Manufacturing Numbers:
9500558 (Domestic)
9500733 (International)
IPX3
C
US
CM
Original Instructions
P/N 1011317 Rev. F 08/18
www.antunes.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DCH-320 SQ and is the answer not in the manual?

Questions and answers

Summary of Contents for Antunes DCH-320 SQ

  • Page 1 ® DCH-320 SQ Display Cabinet Heated Owner’s Manual Manufacturing Numbers: 9500558 (Domestic) 9500733 (International) IPX3 Original Instructions P/N 1011317 Rev. F 08/18 www.antunes.com...
  • Page 2: Table Of Contents

    If any parts are missing or damaged, Service/Technical Assistance place for customers to view. This unit contact Antunes Customer Service In Case of Damage is designed to be used with cooked immediately at +1-877-392-7856 (toll Equipment Information to Save 2 food.
  • Page 3: Safety Information

    Contact only for its intended use as it has a damaged cord or plug, Antunes Technical Service described in this manual. or if it is not working properly. for adjustment or repair.
  • Page 4: Heated Display Cabinet

    Heated Display Cabinet Glass Warnings (DCH Models) Please follow the Safety Instructions below in order to reduce the chance of damaged/broken glass: Warning: Mishandling this product or failure to follow these instruc- tions may result in shattering glass. DO NOT scratch, chip, or nick the glass. DO NOT place any metal objects in contact with the glass (merchandise holders, signs, etc.).
  • Page 5: Specifications

    Specifications Dimensions Electrical Ratings Model & Volts Watts Amp. Mfg. No. DCH-320 1800 15.0 50/60 9500558 Electrical Cord & Plug Configurations Model & Description Configuration Mfg. No. Power Cord DCH-320 NEMA 5-20P 9500558 20 Amp., 120 Volt Power Cord DCH-320 16 Amp., 250V 9500733 CEE 7//7 P/N 1011317 Rev.
  • Page 6: Installation

    2. Open the large box. Remove all packing materials and protec- tive coverings from the unit and parts. NOTICE: If any parts are missing, contact Antunes Technical Service IMMEDIATELY at +1-877-392-7854 in the U.S., or +1-630-784-1000 outside the U.S.. 3. Wipe all surfaces of the unit with Figure 1.
  • Page 7: Operations And Programming

    Operations and Programming Note: Back of unit shown The Setpoint temperature is the desired cabinet temperature set- Control Panel Key Pad ting. When the Temp UP button is pressed and held (and provided that the unit is up to temperature), the actual cabinet temperature is displayed.
  • Page 8: Display Codes

    Display Codes (DCH-320) This section describes the different display codes and their meanings. “LO” flashes during the initial warm up period. The unit continues to display this code until the unit reaches the setpoint temperature. When the unit reaches the set- point temperature, it displays the setpoint temperature.
  • Page 9: Maintenance

    Maintenance Daily Cleaning The unit requires a minimum amount Be sure to follow all of the warnings of maintenance. To ensure proper and precautions listed in the Import- operation, clean the unit at the end of ant Safety Information section of each serving day.
  • Page 10: Parts Replacement

    Parts Replacement Front Glass Replacement CAUTION 1. Turn the unit OFF, unplug the Halogen Quartz Bulb When unlocking or locking the power cord from the electrical Front Glass Security Paddles Replacement outlet, and allow the unit to cool (Figure 8), make sure another CAUTION to room temperature before person is holding the Front Glass...
  • Page 11: Top Glass Replacement

    Top Glass Replacement Side Glass Replacement Rear Door Replacement 1. Turn the unit OFF, unplug the 1. Turn the unit OFF, unplug the 1. Turn unit off, unplug the power power cord from the electrical power cord from the electrical cord, and allow the unit to cool outlet, and allow the unit to cool outlet, and allow the unit to cool...
  • Page 12: Troubleshooting

    Troubleshooting WARNING To avoid possible personal injury and/or damage to the unit, inspection, test and repair of electrical equipment should be performed by qualified service personnel. The unit should be unplugged when servicing. Problem Possible Cause Corrective Action No heat and lights do not turn on Power cord is not plugged in.
  • Page 13 Replacement Parts (Sheet 1) NOTICE Use only genuine Antunes re- placement parts in this display cabinet. Use of parts other than those supplied by the manufactur- er will void the warranty. Item Part # Description QTY. Item Part # Description QTY.
  • Page 14 Replacement Parts (Sheet 2) 22 23 DETAIL A NOTICE Use only genuine Antunes re- placement parts in this display cabinet. Use of parts other than those supplied by the manufactur- er will void the warranty. Item Part # Description QTY.
  • Page 15 Replacement Parts (Sheet 3) NOTICE Use only genuine Antunes re- placement parts in this display cabinet. Use of parts other than those supplied by the manufactur- er will void the warranty. Item Part # Description QTY. 0501869 Pan Support 0502172...
  • Page 16: Wiring Diagram (120V)

    Wiring Diagram (120V) P/N 1011317 Rev. F 08/18 ®...
  • Page 17: Wiring Diagram (230V)

    Wiring Diagram (230V) P/N 1011317 Rev. F 08/18 ®...
  • Page 18: Notes

    NOTES P/N 1011317 Rev. F 08/18 ®...
  • Page 19: Limited Warranty

    2. Antunes reserves the right to make changes in design or add any improvements on any product. The right is always reserved to modify equipment because of factors beyond our control and government regulations. Changes to update equipment do not constitute a warranty charge.