Advertisement

Quick Links

EMI 2– EMIZB-141
Technical manual
Revised 24.04.2023.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EMI 2-EMIZB-141 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Develco EMI 2-EMIZB-141

  • Page 1 EMI 2– EMIZB-141 Technical manual Revised 24.04.2023.
  • Page 2: Table Of Contents

    Features ................................................ 6 EMI 2 – EMIZB-141 ..........................................6 Key features ............................................6 Endpoints................................................. 7 Zigbee Device Object (ZDO) ......................................7 Develco Utility ............................................7 Metering Device ........................................... 7 Supported Clusters ..........................................8 Metering cluster for EP 0x02 ...................................... 8 3.1.1 Basic –...
  • Page 3 Action on Power On ........................................19 General network behaviour ......................................20 Installation ............................................20 Normal – Keep alive ........................................20 5.2.1 Network lost ..........................................20 Low battery ............................................21 Specifications ............................................22 Contact Information ..........................................23 Develco Products A/S Tangen 6 http://develcoproducts.com DK-8200 Aarhus N info@develcoproducts.com...
  • Page 4 Develco Products assumes no responsibility for any errors, which may appear in this manual. Furthermore, Develco Products reserves the right to alter the hardware, software, and/or specifications detailed herein at any time without notice, and Develco Products does not make any commitment to update the information contained herein.
  • Page 5: Cautionary Notes

    Develco Products A/S reserves the right to make changes to any product to improve reliability without further notice. Develco Products A/S does not assume any liability arising out of the application or use of any product or circuit described herein; neither does it convey any license under patent rights or the rights of third parties.
  • Page 6: Features

    The External Meter Interface 2 comes with an optical probe, which is easily attached by a magnet. The cable length is approximately 800 mm. 2.2 Key features • LED sensor • ZigBee OTA cluster for firmware upgrades • ZigBee 3.0 certified Develco Products A/S Tangen 6 http://develcoproducts.com DK-8200 Aarhus N info@develcoproducts.com...
  • Page 7: Endpoints

    • Application device Id 0x0000 • Supports all mandatory clusters. 2.4 Develco Utility • Application profile Id 0xC0C9 (Develco Products private profile) • Application device Id 0x0001 • Manufacturer code for Develco Products is 0x1015. • Private profile for internal Develco Products uses only.
  • Page 8: Supported Clusters

    3 Supported Clusters Metering cluster for EP 0x02 3.1.1 Basic – Cluster id 0x0000 (Server) Only the first set has mandatory attributes, also the optional attributes that can be relevant to a Develco device are all in set 0x000. 3.1.1.1...
  • Page 9: Power Configuration - Cluster Id 0X0001 (Server)

    Relevance and ref. 0x00 Identify Query Response Uint16 - Identify Time (seconds) ZCL 3.5.2.4 3.1.4 Poll Control - Cluster id 0x0020 (Server) The poll control cluster is described in ZCL section 3.16 Develco Products A/S Tangen 6 http://develcoproducts.com DK-8200 Aarhus N info@develcoproducts.com...
  • Page 10: Attribute

    EMI 2 will send a check-in command in the interval specified in attribute “Check-in Interval. The coordinator has to reply with a check-in response. If it doesn’t find a poll client, it will search again periodically. Develco Products A/S Tangen 6 http://develcoproducts.com DK-8200 Aarhus N info@develcoproducts.com...
  • Page 11: Metering - Cluster Id 0X0702 (Server)

    Summation Formatting, and Demand Formatting attributes. Equations required to accomplish this task are defined below: Summation = Summation Delivered * Multiplier / Divisor (formatted using Summation Formatting) Develco Products A/S Tangen 6 http://develcoproducts.com DK-8200 Aarhus N...
  • Page 12: 0X04 Historical Attribute Set

    8,388,607 Above attribute description is to be found in section 10.4.2.2.5 “Historical Consumption” in ZCL provided by the CSA 3.1.5.5 Manufacture Specific Attributes Develco Manufacture code is 0x1015. Table 1 : Formatting Attribute Set (Manufacture Specific) Identifier Name Type...
  • Page 13: Commands

    Summation setting because Pulse Configuration is used when calculating the total amount of detected pulses. 3.1.5.6 Commands The metering cluster support sending 1 command. Name Man/Opt Relevance and ref. 0x00 Get Profile Response ZCL 10.4.2.3.1 Develco Products A/S Tangen 6 http://develcoproducts.com DK-8200 Aarhus N info@develcoproducts.com...
  • Page 14: Meter Identification - Cluster Id 0X0B01

    Uint16 0x0000 to 0xFFFF 0x0109 APS Tx Ucast Success Uint16 0x0000 to 0xFFFF 0x010A APS Tx Ucast Retry Uint16 0x0000 to 0xFFFF 0x010B APS Tx Ucast Uint16 0x0000 to 0xFFFF Develco Products A/S Tangen 6 http://develcoproducts.com DK-8200 Aarhus N info@develcoproducts.com...
  • Page 15: Time - Cluster Id 0X000A (Client)

    Upgrade Server ID Address 0x0001 File Offset Uint32 0x0002 Current File Version Uint32 0x0004 Downloaded File Version Uint32 0x0006 Image Upgrade Status Enum8 0x0007 Manufacturer ID Uint16 0x0008 Image Type ID Uint16 Develco Products A/S Tangen 6 http://develcoproducts.com DK-8200 Aarhus N info@develcoproducts.com...
  • Page 16: Commands

    The OTA Client cluster can receive 4 commands. Man/Op Name Relevance and ref. 0x00 Image Notify ZCL 11.13.1 0x02 Query Next Image ZCL 11.13.1 Response 0x05 Image Block Response ZCL 11.13.1 0x07 Upgrade End Response ZCL 11.13.1 Develco Products A/S Tangen 6 http://develcoproducts.com DK-8200 Aarhus N info@develcoproducts.com...
  • Page 17: Ota Upgrade Messages Diagram

    EMI 2 – EMIZB-141 – Technical manual 3.1.9.3 OTA Upgrade Messages Diagram Develco Products A/S Tangen 6 http://develcoproducts.com DK-8200 Aarhus N info@develcoproducts.com...
  • Page 18: Mmi User Guide

    3 sec until a cluster match is found. When a match is found, or the cluster examine is finished the blinking stops and the device sends a message to the target device to stop the identify time. The following clusters are support in EZ-mode finding and binding: Develco Products A/S Tangen 6 http://develcoproducts.com DK-8200 Aarhus N info@develcoproducts.com...
  • Page 19: Ez Mode - Target

    If a device has joined a network and is powered down, it will attempt to rejoin this network upon power up. For the first 30 seconds hereafter, the device will be available for communication. This time can be expanded using the poll control cluster functionality. Develco Products A/S Tangen 6 http://develcoproducts.com DK-8200 Aarhus N info@develcoproducts.com...
  • Page 20: General Network Behaviour

    When the device is in scan mode the YELLOW LED will flash once every second until it re-joins the network. According to the ZigBee specification TX is NOT allowed to be enabled all the time and a TX silent period must be defined. Develco Products A/S Tangen 6 http://develcoproducts.com DK-8200 Aarhus N info@develcoproducts.com...
  • Page 21: Low Battery

    The current battery voltage can be read from the power configuration cluster described in section 3.3.2.2.4. The attribute “BatteryVoltage” is measuring the battery voltage, in units of 100mV. Low batt LED indication – YELLOW LED will blink twice every 60 second. Develco Products A/S Tangen 6 http://develcoproducts.com DK-8200 Aarhus N info@develcoproducts.com...
  • Page 22: Specifications

    Supports LED pulses (configurable pulse range from 50 to 10 000 pulses per Interfaces kWh) Communication Wireless protocol ZigBee 3.0 ZigBee end-device Certifications Conforming to CE, UKCA, FCC, IC, ISED, RED and RoHS directives Zigbee 3.0 certified Develco Products A/S Tangen 6 http://develcoproducts.com DK-8200 Aarhus N info@develcoproducts.com...
  • Page 23: Contact Information

    EMI 2 – EMIZB-141 – Technical manual 7 Contact Information Technical support: Please contact Develco Products for support. products@develcoproducts.com Sales: Please contact Develco Products for information on prices, availability, and lead time. info@develcoproducts.com Develco Products A/S Tangen 6 http://develcoproducts.com DK-8200 Aarhus N...

Table of Contents