Dometic RM4873 Manual page 14

3-way elite
Hide thumbs Also See for RM4873:
Table of Contents

Advertisement

FIG. 12
using a flue brush. Blowing compressed air into the
flue will not properly clean soot and scale out of the
flue tube. Replace spiral baffle and flue cap.
8) Clean burner tube with a brush. Blow out burner with
compressed air.
9) Before removing burner jet, clean burner area of soot
and scale that fell out of flue tube. Remove the burner
jet. Soak the jet in wood alcohol and blow it out with
compressed air. Reinstall and tighten burner jet.
DO NOT use a wire or pin when cleaning the burner jet
as damage can occur to the precision opening. This can
cause damage to the refrigerator or create a fire hazard.
10) Reinstall burner, being careful that the end of the
burner fits into the slot on the burner bracket. Check
to make sure slots are centered under the flue tube
and the thermocouple is positioned properly (tip of
thermocouple extends over two slots of burner).
GAS EQUIPMENT ASSEMBLY
MANUAL SHUTOFF VA LVE
Use a quarter dollar or a slotted screwdriver
to change position
INLET FITTING
PRESSURE TEST
PORT
SOLENOID VA LVE
BURNER MOUNTING SCREWS
SPARK
BURNER
ELECTRODE
JET
11) Be sure to reconnect the wire to high voltage elec-
trode. Check the electrode for proper location and
gap. (See FIG. 13).
FIG. 13
12) Turn on manual gas shutoff valve and check all
fittings for leaks.
13) Connect 120 volt power cord to the outlet and
reconnect or turn on the 12 volt DC power.
14) Check LP gas safety shutoff. See Section A. Instal-
lation, Item 9. Testing LP Gas Safety Shutoff .
F. FUSES
The 3-way Elite models are equipped with 3 fuses, one for the
refrigerator control system, one for the AC cartridge heater
and a third fuse for the DC cartridge heater (see Table below).
To replace fuse(s) proceed as follows:
1. Disconnect the wall plug, and the 12 volt wires.
2. Remove the power module cover. See FIG. 6.
3. Snap the fuse out of the fuse holder.
4. Fit a new fuse in to the fuse holder.
5. Replace the power module cover.
Control System
AC Heater
DC Heater
14
THERMOCOUPLE
BURNER
TUBE
ELECTRODE
1/8" T O 3/16"
(3-5 mm)
BURNER T UBE
3-amp
5-amp