Summary of Contents for Bloomfield Koffe-King Wunder-Bar 8573
Page 1
OWNERS MANUAL 2060 Cessna Dr, Suite 100 Vacaville, CA 95688 telephone: 707-448-5151 MODULAR fax: 707-448-1521 www.bloomfieldworldwide.com BREWING SYSTEMS MODELS Includes: POUR OVER AUTOMATIC AUTOMATIC UNITS UNITS UNITS Installation WITH FAUCET 8542 8573 8540 Use & Care Servicing Instructions 8571 Model 8572 Brewer with optional 8900-Series Glass Decanters 75804...
Page 2
WARRANTY STATEMENT All electrical equipment manufactured by BLOOMFIELD is removed or unauthorized service personnel perform service. warranted against defects in materials and workmanship for a period of (1 year labor, two year parts) from the date upon the limitations in this warranty. Seller’s obligation under...
TABLE OF CONTENTS WARRANTY STATEMENT Thank You for purchasing this SPECIFICATIONS FEATURES & OPERATING CONTROLS PRECAUTIONS & GENERAL INFORMATION AGENCY APPROVAL INFORMATION INSTALLATION INSTRUCTIONS OPERATION BREWING COFFEE CLEANING INSTRUCTIONS TROUBLESHOOTING SUGGESTIONS SERVICING INSTRUCTIONS EXPLODED VIEWS & PARTS LISTS WIRING DIAGRAMS SPECIFICATIONS...
PRECAUTIONS AND GENERAL INFORMATION WARNING: ELECTRIC SHOCK HAZARD WARNING service personnel. Do not open any access panels which require the use of tools. Failure to heed this warning can result in electrical shock. WARNING: W W W INJURY HAZARD WARNING all applicable electrical and plumbing codes.
INSTALLATION INSTRUCTIONS READ THIS CAREFULLY BEFORE STARTING THE INSTALLATION IMPORTANT: REFER TO EXPLODED VIEWS PAGES 18 thru 22 FOR To enable the installer to make COMPONENT NAMES/NUMBERS a quality installation and to Unpack the unit. Inspect all components for completeness and minimize installation time, the condition.
Page 7
INSTALLATION INSTRUCTIONS (continued) NOTE: This equipment must NSF requires that the brewer be able to be moved for cleaning be installed to comply with underneath. A applicable federal, state and requirement. See Figure 2 below. local plumbing codes and COPPER LOOPS OR ordinances.
OPERATION IL1697 Fig. 4 Brewer Operation Diagram IMPORTANT: START-UP Tank must be full of For initial start-up, or if the brewer has not been used for an water before connecting extended period of time: brewer to electrical power. • Be sure spray disk and brew gasket are properly installed in the Heating elements will be brew head.
Page 9
OPERATION (continued) WATER HEATER HI-LIMIT THERMOSTAT Water temperature is sensed by a thermobulb inserted into the water tank. This temperature signal is fed to the thermostat, which controls line power to the heating THERMOBULB element. The setpoint temperature is adjustable at the thermostat.
BREWING COFFEE PREPARATION CAUTION: BURN HAZARD PAPER Exposed surfaces of the Exposed s posed s FILTER Add a pre-measured amount of brewer, brew chamber and fresh coffee grounds. decanter may be HOT to Gently shake the brew chamber to BREW the touch, and can cause CHAMBER level the bed of grounds.
CLEANING INSTRUCTIONS PROCEDURE: Clean Coffee Brewer CAUTION: BURN HAZARD PRECAUTIONS: Disconnect brewer from electric power. Allow brewer to cool. Brewing and serving Brewing an Brewing an temperatures of coffee are FREQUENCY: Daily extremely hot. Hot coffee will cause TOOLS: Mild Detergent, Clean Soft Cloth or Sponge serious skin burns.
TROUBLESHOOTING SUGGESTIONS SYMPTOM POSSIBLE CAUSE SUGGESTED REMEDY Check power supply cord Brewer unplugged or circuit breaker tripped Check / reset circuit breaker Thermostat set too low Set for desired temperature Allow to cool Hi-Limit thermostat tripped Reset hi-limit (8786, 8788) Water won’t heat Examine wiring &...
SERVICING INSTRUCTIONS ACCESS PANELS CAUTION: Each warmer plate has a center stud which screws into a SHOCK HAZARD bracket. Warmer plates on Canadian brewers are secured with a nut. Remove button plug on bottom of brewer to access nut Opening access panels or Opening a Opening a on warmer plate.
Page 14
SERVICING INSTRUCTIONS (continued) TEMPERATURE ADJUSTMENT CAUTION: SHOCK HAZARD Unplug power cord or turn circuit breaker OFF. Remove top panel. These procedures involve These pro These pro Pull vent tube out of tank lid and insert a thermometer of known exposed electrical circuits. accuracy in vent hole.
Page 15
SERVICING INSTRUCTIONS (continued) TIMER ADJUSTMENT IMPORTANT: Water pressure must be between 20 p.s.i and water pressure exceeds this Place empty decanter under brew chamber. Press BREW r. T y, a pressure the water supply line. REMOVE TANK LID ASSEMBLY OFF. Turn OFF water IMPORTANT: supply basin pan.
Page 16
SERVICING INSTRUCTIONS (continued) IMPORTANT: When replacing REPLACE HEATING ELEMENT heating element, also replace Remove tank lid assembly as described on page 13. seal gaskets. Remove two hex nuts holding element to cover. Pull element from mounting holes. Reassemble in reverse order. REPLACE SOLENOID BYPASS OUTLET...
Page 17
SERVICING INSTRUCTIONS (continued) REPLACE TIMER ASSEMBLY IMPORTANT: When replacing water faucet coil, also replace seal gaskets. timer to bracket. Disconnect wiring to timer. REPLACE HOT WATER FAUCET COIL NOTE: Any abrasion or seat cup will require replacing r. Pull coil from the seat cup: mounting holes.
Page 18
SERVICING INSTRUCTIONS (continued) PROCEDURE: Delime the Water Tank PROCEDURE: Delime the Water Tank CAUTION: CAUTION CHEMICAL BURN PRECAUTIONS: Disconnect brewer from electric power. HAZARD Allow brewer to cool. Deliming chemicals are caustic. Deliming c Deliming c Wear appropriate protective gloves and goggles during this FREQUENCY: As required (Brewer slow to heat) procedure.
Page 19
Koffee-King™ EXPLODED VIEW & PARTS LIST CABINET & RELATED COMPONENTS IL1700...
Koffee-King™ EXPLODED VIEW & PARTS LIST (continued) ITEM PART NO. DESCRIPTION USED ON 2D-70090 COVER PLATE, WARMER, BLACK, 1/4-28 STUD ALL, MADE IN USA 2D-Z15630 PLATE COVER WARMER, 1/4-20 STUD ALL, MADE IN CHINA 2C-70098 CLIP, PANEL RETAINING 2C-70132 NUT, #8SMS, TINNERMAN (not shown) 2K-70229 BUSHING, HEYCO 2I-70139...
Page 21
Koffee-King™ EXPLODED VIEW & PARTS LIST (continued) HOT WATER TANK ASSEMBLY ALT. GREY N.L.A IL1701 ITEM PART NO. DESCRIPTION USED ON 2C-70134 HOLD-DOWN STRAP 2C-73457 NUT, HEX 8-32 KEPS WS-8512-51 THERMOSTAT (BLACK BODY - INCL. SEAL & MOUNTING SCREWS) N.L.A THERMO (ALT) (GRAY BODY - INCL.
Page 22
Koffee-King™ EXPLODED VIEW & PARTS LIST (continued) INTERNAL PLUMBING COMPONENTS INTERNAL PLUMBING COMPONENTS IL1702 ITEM PART NO. DESCRIPTION USED ON 2V-70104 FORMED TUBE, FAUCET OUTLET ASSEMBLY 10-7/8" LONG 8540, 8572 2V-70111 FORMED TUBE, FAUCET COIL INLET ASSEMBLY 8540, 8572 2E-70451 ADAPTER, 1/4"...
Page 23
Koffee-King™ EXPLODED VIEW & PARTS LIST (continued) ELECTRICAL COMPONENTS IL1703 & & & 2P-Z16730 3 MIN, 120V & & & & & WS-8512-51 THERMOSTAT (BLACK BODY - INCL. SEAL & MOUNTING SCREWS) L - I . c x & SOLENOID REPAIR KITS INLET FITTING KIT INCLUDES: CAP (45a), FITTING (45b), GASKET (45c) &...
Koffee-King™ WIRING DIAGRAMS HI-LIMIT TIMER THERMOSTAT LOWER UPPER WARMER WARMER ELEMENT BLACK BLACK GREEN WHITE WHITE WHITE WHITE BLACK BLACK BLACK MODEL NUMBER SOLENOID READY BREW WARMER WARMER 8540 LIGHT SWITCH SWITCH SWITCH MODEL 8543 ONLY HI-LIMIT THERMOSTAT LOWER UPPER WARMER WARMER BLACK...
Page 25
Koffee-King™ WIRING DIAGRAMS (continued) HI-LIMIT TIMER THERMOSTAT RIGHT LEFT REAR WARMER WARMER WARMER ELEMENT BLACK GREEN WHITE WHITE WHITE WHITE MODEL BLACK NUMBER BLACK 8572 and 8573 SOLENOID READY BREW WARMER WARMER WARMER LIGHT SWITCH SWITCH SWITCH SWITCH...
Need help?
Do you have a question about the Koffe-King Wunder-Bar 8573 and is the answer not in the manual?