Bosch DHI 965 V Operating And Installation Instructions

Hide thumbs Also See for DHI 965 V:

Advertisement

Quick Links

DHI 965 V
Internet: http://www.bosch-hausgeraete.de
Bosch Info-Team: de Tel. 01 80/5 30 40 50 (E 0,12/Min. DTAG)
de Gebrauchs- und
Montageanleitung
en Operating and
installation instructions
fr Mode d'emploi et
notice de montage
nl Gebruiksaanwijzing en
montagevoorschrift
it Istruzioni d'uso
e per il montaggio
es Instrucciones de uso
y de montaje
pt Instruções de serviçio
e de montagem
a

Advertisement

Table of Contents
loading

Summary of Contents for Bosch DHI 965 V

  • Page 1 Gebruiksaanwijzing en montagevoorschrift it Istruzioni d’uso e per il montaggio es Instrucciones de uso y de montaje pt Instruções de serviçio e de montagem Internet: http://www.bosch-hausgeraete.de Bosch Info-Team: de Tel. 01 80/5 30 40 50 (E 0,12/Min. DTAG)
  • Page 2 Seite 03 – 18 pagina 67 – 082 page 19 – 34 página 83 – 098 page 35 – 50 página 99 – 114 pagina 51 – 66 Abb. 1 ELEKTRO ELECTR. KAASU ELETT. GASS min. 650 min. 430...
  • Page 3: Description Of Appliance

    Operating instructions: Description of appliance Operating modes This can be achieved if the combustion air is able to flow through non-lockable openings, e.g. in doors, windows and in conjunction with an air supply/air-intake wall box or by other technical procedures such as reciprocal interlocking.
  • Page 4: Before Using For The First Time

    Before using for the first time Important notes: ❑ Before using your appliance for the first ❑ The Instructions for Use apply to several time, please read these Instructions for versions of this appliance. Accordingly, Use carefully. They contain important you may find descriptions of individual information concerning your personal features that do not apply to your...
  • Page 5 Operating the extractor hood The most effective method of removing vapours produced during cooking is to: ❑ Switch the ventilator ON as soon as you begin cooking. ❑ Switch the ventilator OFF a few minutes after you have finished cooking. Switching on appliance: Fan –...
  • Page 6 Operating the extractor hood Switching off: Special functions There are 2 different ways of switching off Switching on the light automatically, e.g. the appliance. via a timer: Switching off directly: ❑ Fan and light must be switched off. Press the button.
  • Page 7: Filters And Maintenance

    Filters and maintenance Grease filters: Removing and inserting the metal-mesh grease filters: Metal-mesh filters are used to trap the Warning: The halogen bulbs must be grease particles in the cooking vapours. switched off and cool. The filter mats are made from non- 1.
  • Page 8 Filters and maintenance Activated carbon filter: For neutralizing odours in recirculating mode. Caution: As the filter becomes more and more saturated with grease, there is an increased risk of fire and the function of the extractor hood may be impaired. Important: Saturation indicator: Change the activated carbon filter promptly...
  • Page 9: Cleaning And Care

    Cleaning and care Replacing the light bulbs Isolate the extractor hood by pulling out 1. Switch off the extractor hood and pull the mains plug or switching off the fuse. out the mains plug or switch off the electricity supply at the fuse box. ❑...
  • Page 10 Moving the operating unit Setting the saturation indicator You can move the operating unit from If the operating mode is to be switched the middle of the filter drawer to the left over (exhaust air/circulating air mode), the saturation indicator for the filters must also or right side.
  • Page 11: Installation Instructions

    Installation Instructions: Important information The installation of the extractor hood Old appliances are not worthless above gas cooking devices, at a rubbish. Valuable raw materials can be minimum height of 650 mm – Fig. 1 – is reclaimed by recycling old appliances. permitted provided that the following Before disposing of your old appliance, nominal heat loads (Hs) are not exceeded:...
  • Page 12: Prior To Installation

    Prior to installation Exhaust-air mode The exhaust air is discharged upwards This can be achieved if the combustion air through a ventilation shaft or directly is able to flow through non-lockable through the outside wall into the open. openings, e.g. in doors, windows and in conjunction with an air supply/air-intake wall Exhaust air must not be discharged via box or by other technical procedures such...
  • Page 13: Before Installation

    Before installation Exhaust air directed upwards: Optimum efficiency of the extractor hood: ❑ Short, smooth exhaust pipe. ❑ As few bends as possible. ❑ Pipe diameter as large as possible (ideally 150 mm dia.) and wide pipe bends. If long, rough exhaust-air pipes, many pipe bends or smaller pipe diameters are used, the air extraction rate will no longer be at an optimum...
  • Page 14 Preparing the wall cupboard This extractor hood is designed to be 1. Mark two attachment points on both the installed in a wall cupboard with the follo- right and left inside faces of the cup- wing dimensions: board and make holes with a bradawl. width: 600 mm depth: 293 to 350 mm height: min.
  • Page 15 Fitting into wall cupboard 4. Also attach the extractor hood to the left Check door alignment and readjust if and right wall cupboards with 2 screws necessary. each side. First make pilot holes with a 1. Remove grease filter bradawl. (see Operating instructions).
  • Page 16 Fitting into wall cupboard Note: The extractor hood housing can be Moving the operating unit: clad inside the wall cupboard (e.g. with See Operating instructions. chipboard). Attaching the handle moulding: If so, observe the following: A handle moulding must be attached to ❑...
  • Page 17: Electrical Connection

    Electrical connection If permanent connection is required: WARNING: THIS APPLIANCE MUST BE EARTHED The extractor hood may only be connected by an electrician registered with the local IMPORTANT: Fitting a Different Plug: electricity board. The wires in the power cord are colour- A disconnecting device must be provided coded as follows: on the installation side.
  • Page 18 Switching over from exhaust air to circulating air mode Switching the electronic control system 1. Press and hold down the button. to circulating air mode: 2. Press the button for approx. ❑ The extractor hood has been set to 3 seconds. exhaust air mode at the factory.
  • Page 19 5750 204 893 Robert Bosch Hausgeräte GmbH Printed in Germany 0704 Es.