Setting The Flow Temperature In Heating Mode (With No Control Connected); Setting The Flow Temperature In Cooling Mode (With No Control Connected); Handing The Product Over To The End User; 11 Troubleshooting - Vaillant flexoTHERM exclusive Installation And Maintenance Instructions Manual

Table of Contents

Advertisement

10.2.4.4 Remaining feed head for VWF 15x/4
environment circuit pump at nominal
volume flow
A
1200
2
1000
1
800
600
400
200
0
40
50
60
1
Air heat source
2
Ground heat source
3
Ground water heat
source
10.2.4.5 Remaining feed head for VWF 19x/4
environment circuit pump at nominal
volume flow
A
1200
1000
1
800
600
400
200
0
40
50
60
1
Air heat source
2
Ground heat source
3
Ground water heat
source
10.3
Setting the flow temperature in heating mode
(with no control connected)
1.
Activate manual operation.
Menu → Installer level → Configuration → Enable
limp home mode
2.
Press
( ).
The display shows the flow temperature in heating
mode.
3.
Change the flow temperature in heating mode by
pressing
or
.
32
3
70
80
90
100
A
Remaining feed head in
hPa (mbar)
B
Pump output in %
2
3
70
80
90
100
A
Remaining feed head in
hPa (mbar)
B
Pump output in %
Max. heating mode target flow temperature: 75 ℃
4.
Confirm this change by pressing
10.4
Setting the flow temperature in cooling mode
(with no control connected)
1.
Activate manual operation.
Menu → Installer level → Configuration → Enable
limp home mode
2.
Press
twice.
The display shows the value of the flow temperat-
ure in cooling mode.
3.
Change the flow temperature in cooling mode by
pressing
or
4.
Confirm this change by pressing
B
Note
At the factory, the target flow temperature
can be set to between 20 °C and 16 °C in
passive cooling mode.
10.5

Handing the product over to the end user

Explain to the end user how the safety devices work and
where they are located.
Inform the end user how to handle the product.
In particular, draw attention to the safety warnings which
the end user must follow.
Inform the end user of the necessity to have the product
maintained according to the specified intervals.
Pass all of the instructions and documentation for the
product to the end user for safe-keeping.

11 Troubleshooting

11.1
Displaying the Live Monitor (current product
status)
B
Menu → Live Monitor
You can use the Live Monitor to display the current status of
the product.
Status codes – Overview (→ Appendix H)
11.2

Checking fault codes

The display shows a fault code F.xxx. A plain text display
explains the displayed fault code.
Fault codes have priority over all other displays.
Fault codes (→ Appendix J)
If multiple faults occur at the same time, the display shows
the corresponding fault codes for two seconds each in se-
quence.
Rectify the fault.
To restart the product, press
tions).
Installation and maintenance instructions 0020213394_05
(OK).
.
(OK).
(→ Operating instruc-
reset