Operation; Commissioning; General - HADEF EEE Installation, Operating And Maintenance Instructions

Single girder electric overhead travelling crane
Table of Contents

Advertisement

Radio control
1 Lowering (slow - fast)
2 Lifting (slow - fast)
3 Trolley travel left side (slow - fast)
4 Trolley travel right side (slow - fast)
5 Crane travel south (slow - fast)
6 Crane travel north (slow - fast)
7 no function
8 no function
9 start
10 start
11 emergency stop
Pos: 11.4.3 /1_HADEF/7--BEDIENUNG/Elektro/Hängetaster - Tasterfunktion @ 2\mod_1273578675013_52.docx @ 14237 @ @ 1
Push button functions
Relieved push button = stand still
push button half pushed = slow speed
push button pushed completely = fast speed
Red Emergency-Stop button
button pushed = stand still
turn the button clockwise = free functions
Pos: 12.1 /1_HADEF/8--BETRIEB Nur (E+P)/*Ü1*/#. Kapitel - Betrieb @ 0\mod_1176390362673_52.docx @ 3901 @ @ 1
8

Operation

Pos: 12.2.1 /1_HADEF/8--BETRIEB Nur (E+P)/Allgemein/Elektro+Druckluft/04.Alle E @ 1\mod_1185781340750_52.docx @ 7412 @ @ 1
The following, important points must be observed when operating the equipment:
Read the safety instructions.
Never load the devices beyond their working load limit.
When changing the motor turning direction, allow the motor to come to a standstill first.
The prescribed maintenance intervals must be adhered to.
Pos: 12.2.2 /1_HADEF/8--BETRIEB Nur (E+P)/Allgemein/Elektro+Druckluft/04.Zusatz für Elektro @ 1\mod_1193041482179_52.docx @ 8072 @ @ 1
Observe the duty cycle, i.e. intermittent operation S4-40% ED (as per VDE 0530) means that in a period
of 10 minutes the motor can operate – no matter the height of the load – for 4 minutes. It is therefore
irrelevant whether the 4 minutes are continuous (i.e., in case of very high lifting heights) or are made in
intervals.
Pos: 12.2.3 /1_HADEF/8--BETRIEB Nur (E+P)/Allgemein/Elektro+Druckluft/04.Zusatz für Hebezeuge @ 1\mod_1193041504888_52.docx @ 8078 @ @ 1
The lifting tackle or the load must be securely attached to the hook and be seated at the bottom of the
hook. The safety catch must always be closed.
Pos: 12.2.4 /1_HADEF/---ALLGEMEIN/Hinweise/GEFAHR - Losreißen, Personentr.,schweb.Lasten, ex verboten (E+P) @ 0\mod_1176799462104_52.docx @ 4735 @ @ 1
DANGER!
It is not allowed:
pulling loose of stuck loads, dragging of loads and inclined pulling is not allowed.
in explosive atmosphere, except the unit is especially modified for it and marked by an indication label
to transport people
The device is not suitable for use on stages and in studios
persons must not stand under a suspended load
Pos: 13.1 /1_HADEF/9--INBETRIEBNAHME/*Ü1*/#. Kapitel - Inbetriebnahme @ 0\mod_1177486166685_52.docx @ 5393 @ @ 1
9

Commissioning

Pos: 13.2.1.1 /1_HADEF/9--INBETRIEBNAHME/Allgemein/Allgemein/01.Allgemein @ 0\mod_1172504961658_52.docx @ 355 @ @ 1
9.1

General

Should the unit be used in Germany:
Please observe the validated, national accident prevention regulations.
For other countries:
Inspections as above. Please observe the national rules and regulations and the instructions in this manual!
12
Illustration 10
Illustration 11
Illustration 12
5.52.707.00.01.02

Advertisement

Table of Contents
loading

Table of Contents