Rear Panel - Inter-m NEP-1200 Operation Manual

Network emergency panel
Table of Contents

Advertisement

Rear Panel

Rear Panel
1
1. AC POWER INPUT TERMINAL
This terminal supplies power to this instrument. The power used is AC 120-240V, 50/60Hz. Do
not excessively bend, pull, twist, heat, or cut the power cord. Doing so may damage the cord and
cause fire or electric shock.
2. AC POWER SWITCH
This switch turns the AC power of the equipment on and off.
3. DC 24V POWER INPUT TERMINAL
This is an emergency spare battery (DC 24V) connection terminal. If an AC power failure occurs,
the equipment operates with the connected spare battery. When DC 24V power is applied to the
equipment, the equipment always operates regardless of the power switch.
4. NETWORK CONNECTION TERMINAL
This terminal is used to connect equipment to the network. Broadcasting can be controlled through
integrated software.
※ For the setting method, refer to the integrated software manual. Please download the manual
from the website (www.inter-m.net).
LINK
ACT
2
3
<100 Base-T>
PIN NO
Function
1
TXP
2
TXN
3
RXP
4
NA
5
NA
6
RXN
7
NA
8
NA
NETWORK EMERGENCY PANEL
4
5
<1G Base-T>
PIN NO
Function
1
MX(0)+
2
MX(0)-
3
MX(1)+
4
MX(2)+
5
MX(2)-
6
MX(1)-
7
MX(3)+
8
MX(3)-
NEP-1200
5