28 |
DT 4.2, DT 4.4, DT 4.6, DT 4.8
8.5
MEDIA LINES
WARNING
Risk of injury due to stored residual energies
Lines, hoses, pipes, valves and connections must be checked for damage (leaks) at regular intervals.
It is essential to observe the following instructions when carrying out maintenance and servicing work on media lines:
• Before starting work on media lines, the system must be depressurised and secured against being switched on
again. Residual energy must be dissipated or discharged. Residual liquids in media lines must be drained off
8.6
CONDITIONS FOR RECONNECTION
Before restarting after maintenance and servicing activities, the following points must be observed:
• Unauthorised persons are to be expelled from the pump.
• Check for proper connection between the pump and the media lines.
• The media lines must be checked for leaks and damage.
• The power supply must be checked for damage and proper functioning.
• All protective devices must be present, functional and tested.
8.7
SPARE AND WEAR PARTS
WARNING
Safety risk due to spare parts not approved by the manufacturer
A comprehensive spare parts list with all spare and wear parts of the series listed here can be found on our homepage
under the following link:
www.becker-international-shop.com
Check capacitor
Pumps with 1~motor usually need a capacitor.
Over time, however, it loses capacity.
Measure the actual capacity and compare it with the nominal capacity
(see condensation door).
Replace in case of major deviations
Clean surface with compressed air
The pump must be cleaned regularly. The interval depends on the degree
of contamination on the casing.
Safety goggles and an FFP2 mask according to EN 149:2008 must be
worn during cleaning.