Advertisement

30 |
DT 4.2, DT 4.4, DT 4.6, DT 4.8
4.
Shut off media lines and divert pressure differences if necessary.
5.
Disconnect the media lines from the pump.
6.
Clean the pump thoroughly
7.
Disassemble the pump in reverse order of assembly or according to separate disassembly instructions. Loose
parts must be secured to prevent them from tipping over or falling down.
8.
Protect the pump from further contamination
8.11

STORAGE

The following requirements for the storage location must be observed during storage in order to store the unused
pump in a proper condition over a longer period of time. If the following requirements are not observed, damage to
the pump may occur. The storage location must
• the storage place must be dry and clean
• the storage place must be level
• the storage place must be protected from sudden changes in temperature and humidity
• the storage location must be protected from salt spray, industrial gases, corrosive liquids, rodents and fungal
attack
• Suction and pressure connections of the pump must be closed, filter covers must be fitted.

8.12 DISPOSAL

NOTE
For a description of the safety instructions, see chapter 2.9
Disposal of the pump takes place in the dismantled state. See chapter 8.10
When disposing of the pump, the relevant local statutory environmental regulations for environmental protection
must be observed.