• Do not leave a battery on prolonged charge when Avoid prolonged, direct exposure to the vapour not in use. generated by Testifire XTR2. Safety Data Sheets for • Do not use any battery which is not designed for the Testifire XTR2 battery pack and Testifire XTR2 use with this equipment.
◦ Restrictions detailed in the Technical Information (see Section 12). • Testifire XTR2 may be used in ceiling and floor voids but care must be taken to ensure that the unit and cup can pass through gaps in both directions.
Removing the Battery for Charging Replacing the Battery Removing and Replacing the Membrane Detectortesters Cloud Portal Registering a New Account Verifying Your New Account Registering and Purchasing a Subscription for Testifire XTR2 8.3.1 Registering Testifire XTR2 8.3.2 Purchasing a Subscription for Testifire XTR2 8.3.3...
Page 5
9.8.6 Push Notifications 9.8.7 Vibration/Sound 9.8.8 Help 9.8.9 Give Feedback 9.8.10 Terms & Conditions 9.8.11 Privacy Policy 9.8.12 Deactivate Account 10. Consumables and Accessories 11. Troubleshooting 11.1 Device Error Codes 12. Support & Technical 12.1 Maintenance 12.2 Technical Information 12.3 Support Contact Testifire XTR2...
1.1 Warranty 1.4 Privacy Policy In addition to any other express warranty given in writing by Testifire XTR2 and Detectortesters Connect are covered by the the Company in relation to the Goods, the Company warrants Detectortesters (No Climb Products) privacy policy. Full details that the Goods supplied under these terms and conditions will of the policy can be found on the Detectortesters website.
Thank you for purchasing the Testifire XTR2 multifunction Smoke-Heat Detector Tester. This manual is designed to assist you to get the best and most efficient use of the Testifire XTR2 and provides all the information required to perform routine service and maintenance tasks with ease. Testifire XTR2 includes advanced technology that simplifies functional testing of smoke, heat and multi-function detectors in the field.
• When replacing a generator, any dust or debris within • Do not charge the battery outside of the specified the Testifire XTR2 housing can be removed using an air operating temperature range (5-45°C). duster. Any condensation can be removed by wiping •...
WARNING Figure 4 Do not touch the contacts on the PCB on the cartridge. Static electricity may cause damage and contamination of the contacts must be avoided. Figure 3 Testifire XTR2...
USING TESTIFIRE XTR2 4.1 Attaching Testifire XTR2 to Solo Access Poles Testifire XTR2 is designed for use with the Solo range of access poles (purchased separately). The product is not compatible with alternative poles. WARNING When working at height it is recommended that a Take the Solo access pole and press down the locking button on competent person carries out a suitable risk Testifire XTR2.
The detector should touch the base of the Testifire XTR2 clear standoff and should be level with the base of the detector (Fig. 7) Adjust the head unit for the correct angle to access the detector.
The test will begin automatically LED and automatically end the test. When powered on, Testifire XTR2 LCD when the tester cup is placed over the will be configured to perform a smoke detector, breaking the infrared beam.
The status LED will flash triple red to indicate the test has been unsuccessful Avoid placing hands near the and you should remove Testifire XTR2 duct outlet during heat testing or by gently lowering it. within 5 minutes of conducting heat testing.
5.3 Combined Test Using Testifire XTR2 to carry out The test will begin automatically When the detector is activated, the combined testing means that a when the tester cup is placed over the optical LED reader inside the tester number of operations (Smoke, Heat detector, breaking the infrared beam.
5.4 Sequential Test Using Testifire XTR2 to carry out a The test will begin automatically Once the Sequential test is complete, sequential test means that a when the tester cup is placed over the the status LED’s will flash triple number of operations (Smoke, Heat detector, breaking the infrared beam.
1. Open the Detectortesters Connect app on your mobile device To perform clearing on its own, download the Detectortesters 2. Pair your Testifire XTR2 device and start a new test job Connect app start a new Test Job: 3. Select your test location and tap “next step”...
Connect app as follows: 1. Open the Detectortesters Connect app on your mobile device 2. Pair your Testifire XTR2 device and start a new test job 3. Select your test location and tap “next step” 4. Select the “Smoke” test mode and tap “Start Test”.
Users should note that using Testifire XTR2 in this configura- the timer the status LED’s will flash orange tion is outside the scope of UL classification for Testifire XTR2. Locate Testifire XTR2 over the sampling hole. Smoke The application has been thoroughly tested independently with will automatically be generated for 20 seconds indicat- all ASD technologies and a wide range of Flat Detectors.
REMOVING AND REPLACING CONSUMABLES All consumable parts of Testifire XTR2 can be replaced in the NOTE: field without having to return the unit for service. Do not re-use empty cartridges. Empty cartridges may be returned to the manufacturer via the reseller for...
Once the generator is inserted do not remove it until Do not force the battery into place. indicated that a replacement is necessary on the LCD display or in the Detectortesters Connect app. WARNING WARNING Do not touch the contacts on the battery or charge cradle.
NOTE: Only register your company once. If you have previously Provide your name, email and password and click “Next” (Fig. 33) registered with Detectortesters Connect, sign in with your email and password or use the “Forgot Password?” option. Figure 33 8.2 Verifying Your New Account...
8.3 Managing Devices and Subscriptions 8.3.2 Purchasing a Subscription for Testifire XTR2 The Devices Dashboard provides a summary of all testers When a new Testifire XTR2 is registered it will receive a grace registered to your company, including: period of 7-days in which it can be used without an active subscription.
• Device serial number • Device name To download a PDF test report, click the download icon to the right-hand side of the test summary and the report will be sent to your email address (Fig. 41) Figure 41 Testifire XTR2...
• Company details • Profile details • User password 8.6.1 Uploading a Company Logo To upload a company logo, click “Upload Logo”. Select your logo from the browser and click “Open (Fig. 44). NOTE: To remove a company logo, click the delete Figure 44 Testifire XTR2...
The “Profile Details” section can be used to edit company To change your password, click “Change Password”. Enter your profile information, including email address and Country. current password followed by your new password, then click (Fig. 46). “Save Changes”. (Fig. 47). Figure 46 Figure 47 Testifire XTR2...
Cloud Portal (Section 8.1) and tap “Next” (Fig. 49) Testifire XTR2. This includes access to advanced test modes and digital test reports that provide proof of compliance. Figure 49 9.1 Downloading the App...
Page 27
Figure 50 Figure 51 NOTE: A company ID is required to register a new profile in the Detectortesters Connect app. If you do not have this, ask your administrator to register your account in the Cloud Portal (Section 8.5) Testifire XTR2...
9.3 Pairing your Testifire XTR2 IMPORTANT: Before you can pair your Testifire XTR2 with the Detectortesters Connect app it must be registered to your company and have an active subscription in the Cloud Portal. This can be done by visiting the Devices section in the Cloud Portal. See Section 8.3 for more information.
If you cannot find your location, tap “Can’t See Location?” and enter the address details manually (Fig. 53). Figure 53 Figure 54 NOTE: The test mode can be changed at any time after starting a test job Testifire XTR2...
9.5 Performing a Test An infrared beam across the tester cup controls the test. The If after two minutes the test has not completed, Testifire XTR2 test will begin automatically when the tester cup is placed over will time-out and the test will be recorded as failed. The app will the detector, breaking the infrared beam.
An active test can be aborted before it is completed by removing When choosing the “Override Result” option, you will be the detector and gently lowering Testifire XTR2. The app will prompted to manually select if the test has passed or failed and indicate the test was aborted and a prompt will appear with you will need to add notes against the test record.
To change test mode, tap “Change Test” and select a new test mode from the list (Fig. 60). When a new mode is selected the status LED’s on Testifire XTR2 will change to indicate the selected mode (see section 4.3)
– clearing any lingering smoke via the vent in the cup. Figure 61 Select the clearing mode by tapping “Clearing” in the top right hand corner. Once selected, the status LED’s on Testifire XTR2 will change to solid white (Fig. 62) Figure 62 NOTE: The correct alarm detection mode must be set for the detector under test.
ASD systems and Flat Detectors can be tested using the ASD Adaptor (Product Code: TESTIFIRE-ADAP-001). See section 6.2 for guidance on fitting the adaptor to the Testifire XTR2 test cup. Change the test mode to ASD once the ASD adaptor is installed and select a delay duration of either 5, 20 or 40 seconds (Fig. 63)
Page 35
Tap “start” when you are ready to begin the timer and begin positioning Testifire XTR2 (Fig. 64) Figure 64 Testifire XTR2...
“Finish Test”. add any final test notes before tapping “Next” (Fig. 66) Select any additions you have tested whilst on site and add op- tional notes to give more detail, then tap “Next” (Fig. 65). Figure 65 Figure 66 Testifire XTR2...
Page 37
Test Job. If required, have the client sign off the job with their signature and details before tapping “Close Test Job” (Fig. 67). Figure 67 NOTE: Test details cannot be edited after the job is closed. Ensure all testing is complete with appropriate notes before closing a Test Job. Testifire XTR2...
Once a Test Job is closed it will be listed on the “My Test Jobs” To view a summary, tap the desired job from the My Test Jobs dashboard on the home screen (Fig. 68) dashboard or use the Search function (Fig. 69) Figure 68 Figure 69 Testifire XTR2...
Page 39
To share a PDF test report, tap the share icon in the top right and enter the recipients email address (Fig. 70) Figure 70 Testifire XTR2...
Detectortesters Connect app on your mobile device. 9.8.8 Help The Detectortesters Connect app includes access to a range of help and support videos so you can make the most of Testifire XTR2. To access the content, tap the settings icon in the top right hand corner from the home screen and select the “Help”...
9.8.9 Give Feedback Select this option to give us your feedback on the Detectortesters Connect app 9.8.10 Terms & Conditions This menu allows you to view the latest Terms & Conditions for Detectortesters Connect 9.8.11 Privacy Policy This menu allows you to view the latest Privacy Policy from Detectortesters 9.8.12 Deactivate Account...
Check the fan moves freely, if not remove the smoke car- Remove the battery and check the charge indicator. If empty, tridge and generator from within Testifire XTR2. Fan faults recharge the battery. (Fig. 73). may occur to due debris getting inside the unit. Carefully use an air duster and apply to the fan or rotate the fan gen- tly.
11.1 Device Error Codes In the event of a system fault, Testifire XTR2 will display an error code on the LCD display. Every error code is unique and represents a different fault. Error Description Required Action Code Unit self-deactivated due no connection to Detec-...
SUPPORT & TECHNICAL 12.1 Maintenance The Testifire XTR2 unit contains no user serviceable parts. Do not disassemble. In the case of a build-up of dust or dirt on the surface of the product, wipe with a slightly damp lint-free cloth. The area around the smoke/heat duct and within the cup should be cleaned periodically to remove any dirt or fluid.
• Automatic torch in dark environment • Adjustable multi-position head • Bt enabled to communicate with detectortesters-connect app • Requires separate subscription for detectortesters-connect app and cloud-portal Safety features: General safety features • Auto-shutdown feature. If the unit is inactive for more than 10 minutes, the unit automatically shuts down which disconnects the control circuit from the battery pack.
For help and support, please use contact your local service centre with your product serial number and any error code to hand. United Kingdom Americas No Climb Products Ltd. SDi, LLC Welham Green, AL9 7JE 3535 Route 66, Building 6 Neptune, NJ 07753 Tel: +44 (0) 1707 282760 Tel: 732-751-9266 Email: detectortesters-connect@detectortesters.com Email: service@sdifire.com Web: https://detectortesters.com/troubleshooting Web: https://sdifire.com/support/ Testifire XTR2...
Page 48
As our policy is one of continuous improvement, details of products described within this publication are subject to change without notice. All in- formation provided here is believed to be correct at the time of going to press. Every effort has been made to ensure the accuracy of information which is provided in good faith but nothing contained herein is intended to incorporate any representation or warranty, either express or implied or to form the basis of any legal relations between the parties hereto, additional to or in lieu of such as may be applicable to a contract of sale or purchase.
Need help?
Do you have a question about the testifire XTR2 and is the answer not in the manual?