Installer
To assure you install this model easily and correctly, PLEASE READ THESE
SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION.
CHECK YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING,
ELECTRICAL AND OTHER APPLICABLE CODES. After installation, leave
these instructions inside the fountain for future reference.
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON
IMPORTANT! INSTALLER PLEASE NOTE.
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER
LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY
FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN, CREAT-
ING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT
OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED. ANY
DRAIN FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE
THE FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM.
FIG. 1
19
FIG. 3
LCRSPD10_2AQ
Soft Sides
Refrigerated Fountains
®
IMPORTANT
29
29
9
PAGE 1
14
16
12 8
38
10
FIG. 2
30 15
22
1000002394 (Rev. C - 6/15)

Advertisement

loading

Summary of Contents for Elkay Soft Sides LCRSPD10-2AQ

  • Page 1 LCRSPD10_2AQ Installation/Care/Use Manual Soft Sides Refrigerated Fountains ® Installer To assure you install this model easily and correctly, PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL AND OTHER APPLICABLE CODES. After installation, leave these instructions inside the fountain for future reference.
  • Page 2 LCRSPD10_2AQ 14" 354mm MINMUM DEPTH BACK WALL LINE FINISHED WALL LINE 19-3/4" 502mm 3-3/4" 12-1/8" 3-3/4" 95mm 309mm 95mm 18" 22" 558mm 457mm 31-3/8" 797mm 22-1/4" 28-1/8" 564mm 27" 714mm 686mm ADULT ADA REQUIREMENT 13-5/8" 347mm FINISHED FLOOR 4-1/2" 114mm WALL OPENING 3-7/8"...
  • Page 3 LCRSPD10_2AQ FILTER INSTALLATION INSTRUCTIONS Remove front panel of chiller. Note: For color images please visit www.elkay.com. Install 3/8" formed copper tube (item 4) to left side of filter head. Screw locknut hand-tight to seal. See Figures 5 and 14. Mount filter head to chiller using (3) screws (provided). See Figure 6.
  • Page 4: Installation Instructions

    LCRSPD10_2AQ INSTALLATION INSTRUCTIONS Install mounting frame. See rough-in diagram (Figure 4) and mounting frame installation instructions. Install remote chiller. Verify that filter has been installed inside chiller. Slide chiller onto shelf and center it within the shelf guides. NOTE: Building construction must allow for adequate air flow on both sides, top, and back of chiller. See chiller instructions for additional information.
  • Page 5 FIG. 13 FIG. 14 FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620 REPAIR SERVICE INFORMATION TOLL FREE NUMBER 1.800.260.6640 ELKAY MANUFACTURING COMPANY • 2222 CAMDEN COURT • OAK BROOK, IL 60523 • 630.574.8484 PAGE 5 1000002394 (Rev. C - 6/15)

This manual is also suitable for: