Summary of Contents for INCINOLET 4100 Series

  • Page 1 INSTALLATION I MAINTENANCE MANUAL 120 VOLTS (SN 57200–) 240 VOLTS (SN 41000–) 23 / V2...
  • Page 2: Table Of Contents

    PARTS LIST ................. 13 IMPOR TANT S AFE T Y INS TRUC TIONS Serial: WARNING: Do not operate INCINOLET until you have read thoroughly and understand completely all instructions Voltage: and safety rules contained in this manual. Save this manual...
  • Page 3: Manufacture's Statement

    INCINOLET is designed to incinerate human feces, urine, tampons, and toilet paper only. Using INCINOLET to burn items of household trash or food scraps will void your warranty and could cause damage to the INCINOLET and possibly cause property damage or even personal injury.
  • Page 4: How To Use Incinolet

    It will also cause odor and may re- duce the life of the heater. If INCINOLET is used primarily in the morning, with little or no use during the day, then reset the timer to 2 hours to ensure complete incineration.
  • Page 5: How To Install Incinolet

    PREPARING VENT-LINE Vent pipe can run horizontally or vertically. Venting materials can be placed within a wall and INCINOLET can be placed close to a wall at the back. Allow 6 to 8 inches on the right side (facing the toilet) to operate the foot pedal.
  • Page 6 HOW TO INSTALL INCINOLET Continued INSTALLATION KIT The installation kit you ordered with your new INCINOLET toilet includes the materials you will need for a simple through-the-wall installation. Receptacle 20-amp, voltage appropriate for your new toilet. See Electrical Preparation below.
  • Page 7: Tips For Best Venting

    START-UP PROCEDURE - Once Incinolet is connected to vent line and plugged into a 20 amp receptacle on a 20 amp circuit of the appropriate voltage, it’s a good idea to run a test cycle using a cup of water poured...
  • Page 8: Understanding Electrical Operation

    130 degrees F., about 20 to 40 minutes later. Power Consumption One complete cycle uses about 1 1/2 to 2 kilowatt hours of electricity. Because you can use INCINOLET any time during the cycle, your “per use” cost is lower.
  • Page 9: Care & Cleaning

    3. Remove blower wheel and clean. (See page 11.) 4. DO NOT STEAM CLEAN. 5. Stainless steel polish can be used on outside surfaces to keep INCINOLET’s finish lustrous BOWL LINERS BE SURE that the top edges of the liner are below the lid when it closes. Otherwise, paper will burn outside the chamber and cause momentary smoke and odor.
  • Page 10: Troubleshooting

    DO NOT CHANGE SETTINGS TIMER ADJUSTMENT: (See Fig. 8.) Timer dial reads 0 to 3 hrs. Timer pointer is set to 75 minutes. If INCINOLET is used primarily for solid deposits in rapid succession and incineration is incomplete, move pointer to 1.5-2.0 hrs. If used throughout the day, both for urine and solids, timer would be best set at 1 to 1-1/2 hr.
  • Page 11 TROUBLESHOOTING BLOWER STOPS AT END OF HEATING CYCLE Blower should be on from 20 to 40 minutes after heater cuts off. Unplug toilet, remove access panel, inspect, tighten any loose wires. REPLACE BLOWER THERMOSTAT. BLOWER DOES NOT OPERATE Blower must come on immediately when start button is pushed and should not stop while heater is on.
  • Page 12: Part Schematic

    For help with troubleshooting call 1-800-527-5551 or to order parts www.incinolet.com If service is needed, see the data plate on the back of toilet. Please note serial # and voltage of your toilet.
  • Page 13: Maintenance & Repairs

    • Replace thermocouple. Push knurled cylinder to compress spring. Turn to engage stud, then release. Spring must be compressed to insure that tip of thermocouple contacts outer surface of heater. (See p. 12.) • Replace access panel, ashpan, top. Close circuit breaker. • Plug INCINOLET in. Start cycle to test heater and total operation.
  • Page 14 IMPORTANT: EXACT PROCEDURE MUST BE FOLLOWED TO PREVENT OVERHEATING AND HEATER FAILURE: 1. To replace thermocouple, unplug INCINOLET and remove side access panel. Disconnect wire leads with “E” and “F” wire nuts. Then push in knurled rod, turn to disengage, pull out thermocouple.
  • Page 15: Parts List

    TS -Limit thermostat to prevent overheating- L-300 G connects W3, W4, W,8 C connects Wl, W3, W10 SW - Start Switch D connects BL9, BL9 TOLL FREE 1-800-527-5551 Research Products/Blankenship 2639 Andjon Drive Dallas, Texas 75220 (214) 358-4238 Fax (214) 350-7919 www.incinolet.com email: Sales@incinolet.com info@incinolet.com...