WARNING: Do not operate INCINOLET until you have
read thoroughly and understand completely all instructions
and safety rules contained in this manual. Save this manual
and review frequently for continuing safe operation, and
instructing possible third-party users.
SANITATION

Advertisement

Table of Contents
loading

Summary of Contents for INCINOLET WB

  • Page 1 1074 Kenran Industrial Dr. St. Louis, MO 63137 Phone: 1-800-381-9968 Incinolet Toilet Systems WARNING: Do not operate INCINOLET until you have read thoroughly and understand completely all instructions RESEARCH PRODUCTS/Blankenship and safety rules contained in this manual. Save this manual 2639 Andjon •...
  • Page 2: Tips For Success

    RESULTS IN ODOR AND CAN REDUCE LIFE OF THE HEATER. If INCINOLET is used primarily in the morning, with little or no use during the day, then reset the timer to 1 1/2 or 2 hours to insure complete incineration. (See page 8.) Ash is not suitable to use as fertilizer or compost.
  • Page 3 Preparing Vent-Line Vent pipe can run horizontally or vertically. Venting materials can be placed within a wall and INCINOLET can be placed close to a wall at the back. Allow 6 to 8 inches on the right side (facing the toilet) to operate the foot pedal.
  • Page 4: Electrical Preparation

    Fig. 5 Electrical Preparation This appliance has a 20-amp plug and is meant to fit only into a 20-amp receptacle. (Fig. 4) If the outlet you intend to use for the INCINOLET is 120 volts 240 volts not the proper type, then change the receptacle. You must have a circuit suitable for 20 amps, headed by a 20-amp circuit breaker.
  • Page 5: Power Consumption

    During a Power Failure If waste is burning in the INCINOLET when the electric service is interrupted, you may get smoke and odor in the room. Open a window to ventilate as best you can. When power comes back on, the fan should start automatically, if needed, and run until unit is cool enough.
  • Page 6: Care And Cleaning

    3. Remove blower wheel and clean. (See page 10.) 4. DO NOT STEAM CLEAN. 5. Stainless steel polish can be used on outside surfaces to keep INCINOLETʼs finish lustrous. Bowl Liners BE SURE that the top edges of the liner are below the lid when it closes. Otherwise, paper will burn outside the chamber and cause momentary smoke and odor.
  • Page 7 HUMCO SANITATION 1074 Kenran Industrial Dr. St. Louis, MO 63137 Phone: 1-800-381-9968 Incinolet Toilet Schematic Sheet For help with troubleshooting Call Humco VENT or to order parts, call 800-381-9968 1-800-527-5551 ASHPAN PANEL GUARD ACCESS PANEL FOOT PEDAL SEAT & LID...
  • Page 8: Troubleshooting

    Timer dial reads 0 to 3 hrs. Timer pointer is the red light comes on and stays on for a timed set to 1.0 hrs. If INCINOLET is used primarily interval, during which time temperature controller for solids deposits in rapid succession and is activated and its red light is on.
  • Page 9: Maintenance And Repairs

    • Push up on heater coils to clear To Remove Old Heater: lowest position in heater bracket. heater brackets. (Fig. 11-2) • Turn off voltage to INCINOLET. Coils must not touch each other. Remove ashpan. Remove access • Replace insulation and cover over panel.