INCINOLET TR Installation & Maintenance Manual

120 v, 240 v, 208 v

Advertisement

Quick Links

INSTALLATION / MAINTENANCE MANUAL
Models TR and WB - 240 volts
Models CF and WB - 120 volts
Model_______________________
Serial #______________________
Voltage______________________
Date installed_________________
Please have this information handy
when ordering parts. In can be found
on ID plate on back of toilet.
(SN 41000  )
(SN 57200  )
IMPORTANT SAFETY INSTRUCTIONS
WARNING: Do not operate INCINOLET until you have
read thoroughly and understand completely all instructions
and safety rules contained in this manual. Save this
manual and review frequently for continuing safe
operation, and instructing possible third-party users.
For questions or assistance call 1-800-527-5551

Advertisement

Table of Contents
loading

Summary of Contents for INCINOLET TR

  • Page 1 INSTALLATION / MAINTENANCE MANUAL Models TR and WB - 240 volts (SN 41000  ) Models CF and WB - 120 volts (SN 57200  ) IMPORTANT SAFETY INSTRUCTIONS WARNING: Do not operate INCINOLET until you have Model_______________________ read thoroughly and understand completely all instructions Serial #______________________ and safety rules contained in this manual.
  • Page 2: Manufacturer's Statement

    4. Do not install toilet in an explosive atmosphere. 5. Never burn trash or garbage in INCINOLET as it may produce a high flame that could damage the toilet or injure a person. INCINOLET is designed to incinerate human feces, urine, tampons, and toilet paper only. Using INCINOLET to burn items of household trash or food scraps will void your warranty and could cause damage to the INCINOLET and possibly cause property damage or even personal injury.
  • Page 3 It will also cause odor and may reduce the life of the heater. If INCINOLET is used primarily in the morning, with little or no use during the day, then reset the timer to 2 hours to insure complete incineration.
  • Page 4: Electrical Preparation

    Preparing Vent-Line Vent pipe can run horizontally or vertically. Venting materials can be placed within a wall and INCINOLET can be placed close to a wall at the back. Allow 6 to 8 inches on the right side (facing the toilet) to operate the foot pedal.
  • Page 5: Side View

    90 degree elbow turned down or a rain cap if vented vertically. START-UP PROCEDURE - Once Incinolet is connected to vent line and plugged into a 20 amp receptacle on a 20 amp circuit of the appropriate voltage, it’s a good idea to run a test cycle using a cup of water poured into a bowl liner.
  • Page 6: Power Consumption

    During a Power Failure If waste is burning in the INCINOLET when the electric service is interrupted, you may get smoke and odor in the room. Open a window to ventilate as best you can. When power comes back on, the fan should start automatically, if needed, and run until unit is cool enough.
  • Page 7: Care And Cleaning

    3. Remove blower wheel and clean. (See page 10.) 4. DO NOT STEAM CLEAN. 5. Stainless steel polish can be used on outside surfaces to keep INCINOLET’s finish lustrous. Bowl Liners BE SURE that the top edges of the liner are below the lid when it closes. Otherwise, paper will burn outside the chamber and cause momentary smoke and odor.
  • Page 8: Troubleshooting

    Timer dial reads 0 to 3 hrs. Timer pointer is set and the red light comes on and stays on for a to 1 hour. If INCINOLET is used primarily for timed interval, during which time temperature solids deposits in rapid succession and controller is activated and its red light is on.
  • Page 9 For help with troubleshooting VENT or to order parts, call 1-800-527-5551 -USA ASHPAN PANEL From other countries, call agent shown on front cover. GUARD ACCESS FOOT PEDAL If service is needed, see the data plate on PANEL the back of toilet. Please note serial # and voltage of your toilet.
  • Page 10: Maintenance And Repairs

    (See p. 11.) • Replace access panel, ashpan, top. Close circuit breaker. COVER INSULATION PLATE • Plug INCINOLET in. Start cycle to Fig. 11-1 Fig. 11-3 test heater and total operation.
  • Page 11: Safety Features

    TO PREVENT OVERHEATING AND HEATER FAILURE: 1. To replace thermocouple, unplug INCINOLET and remove side access panel. Disconnect wire leads with “E” and “F” wire nuts. Then push in knurled rod, turn to disengage, pull out thermocouple. 2. To install new thermocouple, reverse procedure. Make sure that wire with red core is connected to purple #7 and yellow core wire is connected to gray #6.
  • Page 12 Yellow=Y “E” “F” RELAY E5CS BLOWER Revised 08/18...

This manual is also suitable for:

WbCfSn 41000

Table of Contents