User's Manual
Drying Ovens / Sterilizers
Models
TS 9026 - TS 9053 - TS 9135 - TS 9430
1

Advertisement

Table of Contents
loading

Summary of Contents for Nordic Lab Termaks TS 9026

  • Page 1 User’s Manual Drying Ovens / Sterilizers Models TS 9026 - TS 9053 - TS 9135 - TS 9430...
  • Page 2: Basic Functions

    Basic Functions This page gives you all information needed to operate the chamber. Details are given on the following pages. The display backlight turns into power saving mode 30 sec. after last key hit. Left Display Right Display • Target Temperature •...
  • Page 3: Installation

    Installation • Unpack and place shelves in desired position • Place the chamber with at least 10 cm free air on all sides • Do not connect the air outlet to a ventilation system • Connect the chamber to a grounded power source •...
  • Page 4 Display Only Frames, overview Selected with Up/Down Keys when no light at the Set Key Temperature Target Actual Set 180°C 180 °C Actual Temperature Continuous Mode Status Messages: *TimeLeft 1h 25min *Cycle Complete *Heating Up Alarm Messages: *Cooling Down Main Frame *High Temp Alarm *Sleep Mode Returns automatically to this...
  • Page 5: Settings Menu

    Settings Menu Set Key Set Key LED turns On LED Flashing Up / Down Keys Display Mode Change Mode 3 Sec Pin Code Actual Setting Change Setting Available 30 seconds from startup Pin Code Pin Code 000 means deactivated Pin Code System Up/Down Keys Temperature Target Actual Setting...
  • Page 6 Timers In the System Setup, one of two timer systems can be chosen: Standard Timer (default): • Can be set to maximum 99 hours and 59 minutes • Starts counting down when the Set Temperature is reached • In the case of power failure, lasting more than 5 minutes, the counting will restart from the beginning •...
  • Page 7 °C Week Cycle, example 180°C 180°C Actual Setting Actual Setting Mo 19:45 Fr 05:00 Temp B StartTime Temp B EndTime 100°C Actual Setting 180 °C Temperature Actual Setting 100 °C Temperature B Time Day Cycle, example Actual Setting 100 °C Actual Setting 180 °C Temperature B...
  • Page 8: Alarm Output

    Pin Code • Optional system to stop unwanted settings from unauthorized persons • A personal pin code can be entered during the first 30 seconds after turning the chamber on with the main switch or waking up from Standby Mode. Actual code is displayed after pressing the Set key in that period.
  • Page 9 Schedul/Ramping There can be up to 5 schedules. A new schedul consists of following A start block Start day (All, Mon-Sun, None) Start hour ( 0-23) Start minute ( 0-59) End mode ( Stop, Continue, Cycle, Standby) You can have up to 10 temp blocks in every scheduler. In every block you choose 3 different parameters Run time before shift (hours) ( 0-100, 0=block disabled) Temprature...
  • Page 10 - Here you have all 5 different schedules. - You can set up all 5 differently and then chose which one you want to use. Schedule 3 Schedule 4 Schedule 5 Schedule 1 Schedule 2 Start Start Start Start Start Start Start Start...
  • Page 11 hedual/Ramping explanied in pictures. Here you have what the display show when the Schedule/ramping is activated. Remember that you have 5 different On this page you choose Schedules, every which Schedule you want schedule can be set You can have 5 different differently, here you Scheduals.
  • Page 12 This page shows you how to set the block parameters Here you choose which Remember that you block you want to set, you will need to set all can choose between 10 blocks up like you blocks, when you change want them.
  • Page 13: Sterilization Cycle

    Sterilization Cycle: • A fixed sterilization cycle for the chamber is available, 180°C in 40 minutes. • Enter the “Timer Option” menu under Setup and select Sterilization Cycle “Steriliz” • Sterilization Cycle behaves as Standard Timer, but temperature and time can’t be adjusted.
  • Page 14 Calibration Two calibration constants can be adjusted in order to bring the temperature measurement equal to the true value according to a control device: Amplifying Factor (A) Should be calculated if the chamber is used in a wide temperature range Zero Point Constant (Z) Should be calculated if display and a control device is not equal at normal working temperature...
  • Page 15 Grunnfunksjoner Denne siden viser det som trenges for å betjene skapet. Funksjonene er beskrevet mer i detalj på de følgende sidene. Bakgrunnslyset i displayet går i sparemodus 30 sekunder etter siste knappetrykk Venstre display Høyre display • Ønsket temperatur • Aktuell temperatur •...
  • Page 16 Innstallasjon • Pakk ut og plasser hyllene i ønsket posisjon • Plasser skapet med minst 10 cm luft på alle sider • Spjeldåpningen skal ikke knyttes direkte til eksternt ventillasjonsanlegg • Sett støpselet i en jordet stikkontakt • Slå på skapet med hovedbryteren på høyre side, bak •...
  • Page 17 Displayoversikt, viser aktuelle verdier Velges med Opp / Ned knappene når set LED ikke lyser Ønsket temperatur Actual Set 180°C 180 °C Actual Temperature Continuous Mode Statusmeldinger *Tid igjen 1h 25min *Syklus ferdig *Varmer opp Alarmer: *Kjøler ned Hovedbilde *Høy temp alarm *Hvilemodus Går automatisk til dette bildet *Lav temp alarm...
  • Page 18 Innstillingsmeny Set Knapp Set Knapp LED lyser LED blinker Opp / Ned -knapper Viser innstillinger Kan endre 3 Sek Adgangskode Aktuell børverdi Endre innst. Tilgjengelig i 30 sek etter oppstart. Kode Kode 000 betyr deaktivert adgangskode Opp / Ned -knapper Børverdi temperatur Aktuell børverdi Endre Innst.
  • Page 19 Timere En av to tidsfunksjoner kan velges under Systeminnstillinger Standard (fra fabrikk): • Kan innstilles til maksimun 99 timer og 59 minutter • Begynner å telle ned tiden når ønsket temperatur er oppnådd • Ved et eventuelt strømbrudd som varer mer enn 5 minutter, vil nedtellingen starte fra full tid når strømmen er kommet tilbake •...
  • Page 20 °C Ukesyklus, eksempel 180°C 180°C Aktuell børverdi Aktuell børverdi Fr 05:00 Ma 19:45 Temp B Starttid Temp B Sluttid 100°C Aktuell børverdi 180 °C Temperatur Aktuell børverdi 100 °C Temperatur B Lør Søn Dagsyklus, eksempel Aktuell børverdi 100 °C Aktuell børverdi 180 °C Temperatur B Temperatur...
  • Page 21 Adgangskode • Kan brukes for å hindre andre personer i å gjøre endringer • En personlig kode kan velges i løpet av de første 30 sekundene etter at skapet er slått på. Aktuell kode vises etter et trykk på Set-knappen i denne perioden. Ny kode kan velges i området 001 til 999 •...
  • Page 22 Sikkerhetstermostaten • Et automatisk system som hindrer ødeleggende temperaturer hvis regulatoren svikter • Separat system, helt uavhengig av regulatoren • Justeres automatisk når en ny børverdi mates inn • Justerbar grense (avvik fra børverdi) • Bryter strømmen til varmeelementene når grensen overskrides •...