Technical Description - DAV TECH PCP 005 Installation And Maintenance Manual

Volumetric pumps
Table of Contents

Advertisement

1 INTRODUCTION
1.1 The manual
The user guide is the document that accompanies the pumps from the time of its construction and throughout the period of
use, it is therefore an integral part of the pump. It requires reading the manual before taking any action involving the pump. The
manual must be readily available for use by staff and maintenance of the pump. The user and the attendant use are required to
know the contents of this manual.
Reproduction of any part of this manual, in any form, without the express written permission of DAV Tech. The text and
illustrations in this manual are not binding, the DAV Tech reserves the right, at any time and without notice, the right to make any
changes to improve the product or for reasons of character manufacturing or commercial.
1.2 Warranty
The warranty is valid for a period of 12 months from the date of commissioning and no later than 15 months from the date
delivery. The interventions carried out during the warranty period does not extend in any way the validity period of the guarantee.
The seller is not liable for defects caused by normal wear of parts which by their nature are subject to wear.
1.3 Goods receiving
The original configuration of the pump must never be changed. Upon receipt of the goods, check that:
• The packaging is intact
• The exact correspondence of the material ordered.

2 TECHNICAL DESCRIPTION

2.1 Pumps operation
The PCP volumetric pumps is the state of art in the micro-dispensing world. The pumps are drived by a gearmotor with encoder
and allow volumetric dispensing in strips, drops, or fill a determinated volume with the highest accuracy, without be affected
from inlet fluid pressure, viscosity and temperature of the media etc. The motor, drived in one direction dispense the fluid, and if
drived in the other direction suck back the fluid, preventing dripping and levelling the pressure on the nozzle.
2.2 Technical specification
Item
Dimensions
27xL230xØ27mm 27xL230xØ27mm 27xL230xØ27mm 29xL280xØ29mm 29xL280xØ29mm 29xL312xØ29mm 60xL580xØ60mm
Weight
Input pressure
Max. Dispensing pressure
0~1.000.000 mPa . s 0~1.000.000 mPa . s 0~1.000.000 mPa . s 0~1.000.000 mPa . s 0~1.000.000 mPa . s 0~1.000.000 mPa . s 0~1.000.000 mPa . s
Viscosity
Dispensing Volume/Rev.
Motor Speed (rpm)
Dispensing Flow Rate (Max.)
1
Accuracy of dispensing
Stator Material
Material Inlet Port
2
Material Outlet Port
3
AISI 304 / AL /
Wetted Parts Material
4
UHMW - PE / FKM
Operating Condition
1. Depending on the dispensed fluid - 2.Different inlet, as syringe or catridge fittings available upon request - 3. Different outlet possible upon request - 4. Different
materials possible upon request.
PCP-005
PCP-015
360 g
360 g
0~6 bar
0~6 bar
20 bar
20 bar
≈0.0049 ml
≈0.017 ml
1~120 rpm
1~120 rpm
≈0.6 ml/min
≈1.8 ml/min
±1%
±1%
FFKM
FFKM
G 1/4"
G 1/4"
2
2
Luer Lock
Luer Lock
3
3
AISI 304 / AL /
UHMW - PE / FKM
4
10~40°C
10~40°C
PCP-050
PCP-150
374 g
532 g
0~6 bar
0~6 bar
20 bar
20 bar
≈0.049 ml
≈0.17 ml
1~120 rpm
1~120 rpm
≈6.0 ml/min
≈18 ml/min
±1%
±1%
FFKM
FFKM
G 1/4"
G 1/4"
2
Luer Lock
Luer Lock
3
AISI 304 / AL /
AISI 304 / AL /
UHMW - PE / FKM
UHMW - PE / FKM
4
4
10~40°C
10~40°C
VOLUMETRIC PUMPS PCP
PCP-500
PCP-1000
530 g
0~6 bar
0~6 bar
15 bar
≈0.45 ml
≈1.1 ml
1~120 rpm
1~120 rpm
≈60 ml/min
≈120 ml/min
±1%
FFKM
G 1/4"
G 1/4"
2
2
Luer Lock
Luer Lock
3
3
AISI 304 / AL /
AISI 304 / AL /
UHMW - PE / FKM
UHMW - PE / FKM
4
4
10~40°C
10~40°C
upon request
PCP-2000
700 g
3,5 kg
0~6 bar
20 bar
20 bar
≈2.0 ml
1~150 rpm
≈280 ml/min
±1%
±1%
FFKM
FFKM
G 3/8"
2
2
G 3/8"
3
AISI 304 / AL /
UHMW - PE / FKM
4
4
10~40°C