3. General safety instructions Instructions regarding installation, connection and DANGER! maintenance Failure to observe the instructions in this − The controls must be disconnected from the electricity document can result in mortal danger! supply before carrying out electrical works. It must be ☞...
4. Overview of products The following package options are available for the STA 1 operator: − STA/STAW 1 E (external control unit with release mechanism) − STA/STAW 1 KE (external control unit with chain) − STA/STAW 1 KU (external control unit with emergency hand crank) −...
5. Installation Preparation Push-on assembly WARNING! ATTENTION! Damage due to improper installation of the drive! Incorrect installation of the drive can result in serious injury! To avoid damage to the drive and to the door, the drive must be mounted on a console or a torque support bracket −...
Installation Installation of the emergency hand chain Mounting with torque support bracket (only for operators with emergency hand 5.2 / 2 chain) To ensure that they work correctly, the chain links must not be twisted. 5.3 / 1 ☞ Fit the torque support bracket/console (A). Join the ends of the emergency hand chain together with ☞...
6. Initial Operation Preparation Connection Open the operator DANGER! 6.2 / 1 Danger of fatal electric shock! ☞ Before commencing cabling works, you MUST disconnect the drive system from the mains supply. Ensure that the electricity supply remains disconnected throughout the cabling works.
Page 8
Initial Operation Limit switch connections (plug-in, standard) Additional limit switch, OPEN (standard only for operators without integrated control unit) Limit switch, OPEN 6.2 / 3 Safety limit switch, OPEN Safety limit switch, CLOSED Limit switch, CLOSED Additional limit switch, CLOSED (standard only for operators without integrated control unit) Safety limit switch for emergency manual operation Thermal overload protection for motor...
Page 9
3 x 400 V star connection (standard) 1 x 230V connection The motor is factory-wired for connection to a 3 x 400 V The motor is factory-wired for connection to a 230V/1-phase mains supply in star connection. mains supply. 6.2 / 7 6.2 / 9 ☞...
Initial Operation Manual settings 6.3 / 2 6.3 / 1 Fine adjustment screw Locking screw OPEN additional limit switch - S1 (potential-free change-over contact) Limit switch, OPEN - S2 Each control cam has a locking screw (N) and a fine adjust- Safety limit switch, OPEN - S3 ment screw (M).
Set the OPEN end position Wiring allocation, AVE (absolute value encoder) plug ☞ Drive the door to the OPEN end position. ☞ Set the control cam (H) so that the OPEN limit switch (B) is 6.4 / 2 actuated. ☞ Tighten the locking screw (N).
Initial Operation 7. Emergency operation Check the system WARNING! Improper use may result in serious injury! Check the direction of travel To avoid injury, the following points must be observed: ☞ Drive the door in the CLOSED direction. − Emergency operation must only be carried out from a The operator must close the door.
Page 13
Operation with emergency hand chain Operation with release mechanism 7 / 1 WARNING! Risk of serious injury due to uncontrolled movement of the door! To avoid injury, drive units with a release mechanism require that a fall protection is mounted on the door. Without a fall protection, the door does not comply with directive ASR A1.7.
8. Maintenance DANGER! Danger of fatal electric shock! ☞ Before commencing cabling works, you MUST disconnect the drive system from the mains supply. Ensure that the electricity supply remains disconnected throughout the cabling works. ATTENTION! Improper maintenance of the drive can result in property damage! To avoid damage to the drive and door, the following points must be observed:...
9. Technical data STA 1-11-19 STA 1-10-24 STA 1-13-15 STA 1-12-19 STA 1-11-24 STA 1-10-30 Type (E / KU / KE): STAC 1-11-19 STAC 1-10-24 STAC 1-13-15 STAC 1-12-19 STAC 1-11-24 STAC 1-10-30 Driving torque (Nm): Static holding torque (Nm): Driving motor speed (min -1): Motor output (kw): 0.37...
Page 16
Technical data STA 1-13-15 STA 1-12-19 STA 1-11-24 STA 1-10-30 STAW 1-7-19 Type (E / KU / KE): STAWC 1-7-19 Driving torque (Nm): Static holding torque (Nm): Driving motor speed (min -1): Motor output (kw): 0.55 0.55 0.55 0.55 0.37 Operating voltage (V): 230 / 400 / 3~ 230 / 400 / 3~...
Page 17
STA/STAW 1 E 9 / 1 6.35 4x M8x16 deep, on both sides STA/STAW 1 KE 9 / 2 6.35 4x M8x16 deep, on both sides Sectional door operator STA 1 / Rev. D 0.4 – 17...
Page 18
Technical data STA/STAW 1 KU 9 / 3 6.35 4x M8x16 deep, on both sides STA/STAW 1 E - HD 9 / 4 6.35 4x M8x16 deep, on both sides 18 – Sectional door operator STA 1 / Rev. D 0.4...
Page 19
STA/STAW 1 KE - HD 9 / 5 6.35 4x M8x16 deep, on both sides STA/STAW 1 KU - HD 9 / 6 6.35 4x M8x16 deep, on both sides Sectional door operator STA 1 / Rev. D 0.4 – 19...
Page 20
Technical data STAC/STAWC 1 E 9 / 7 6.35 4x M8x16 deep, on both sides STAC/STAWC 1 KE 9 / 8 6.35 4x M8x16 deep, on both sides 20 – Sectional door operator STA 1 / Rev. D 0.4...
Page 21
STAC/STAWC 1 KU 9 / 9 6.35 4x M8x16 deep, on both sides Sectional door operator STA 1 / Rev. D 0.4 – 21...
10. Manufacturer‘s Declaration Declaration of incorporation MFZ Antriebe GmbH & Co.KG within the context of Machinery Directive 2006/42/EC for incorporation in an Neue Mühle 4 incomplete machine according to Appendix II, Part 1B D - 48739 Legden Declaration of conformity within the context of the directives on Electromagnetic Compatibility 2014/30/EU and RoHS 2011/65/EU We hereby declare that the following listed product Sectional door operator...
Page 23
In case of changes to the product that are not confirmed by us, this declaration is void. Legden, dated 01.07.2018 Dirk Wesseling, General Manager Sectional door operator STA 1 / Rev. D 0.4 – 23...