it is recommended to clean the outlet by
following the steps below.
1. Push the recessed part
of the service cover.
2. Remove the service
cover.
3. Press the removal
button of the brewing
container.
4. Remove the brewing
container.
PROBLEM
The appliance is not op-
erating.
The machine does not
respond at all or responds
late even after pressing
the function button on the
panel several times.
The coffee is not hot
enough.
The coffee can't come out. The system drain function
5. Clean the powder
outlet using the Cleaning
Brush.
J
When you notice an abnormal situation
in your appliance, you may attempt to
troubleshoot according to the following
descriptions.
If your appliance does not still operate
properly, contact Vestel Call Center or
your local Vestel Authorised Service. You
may access the authorized service provid-
ers list and contact information from the
web site. All authorized service informa-
tion is available in the Service Information
System created by the Ministry.
CAUSE
The appliance is not con-
nected to the mains.
- The device may be af-
fected by electromagnetic
interference.
- The panel may be dirty.
- The cups may not have
been heated.
- The brewing container
may be too cold.
may have been used pre-
viously.
16

Troubleshooting

SOLUTION
- Plug in the appliance and
press the button.
- Check the cord and plug.
- Unplug the appliance
from the socket. Restart
the appliance after a few
minutes.
- Clean the panel with the
cloth supplied.
- Rinse the appliance at
least 3 times before mak-
ing coffee.
Press the hot water button
until water comes out by
the spout.

Advertisement