Ca Ale Rt No; Mpc Device I>Ata Alert; Transmission F>Arity Error; Inconsistent Command - Honeywell 6000 Series Reference Manual

Disk storage subsystem
Hide thumbs Also See for 6000 Series:
Table of Contents

Advertisement

CA EN -I Error
The interrupt generated was not the interrupt that the controller was expecting from
the CA.
CA Alert No EN-I
The controller commanded the CA to some action and no interrupt was generated
(e. g., CA terminal out).
MPC DEVICE DATA ALERT
The MPC Device Data Alert status is an expansion of the Data Alert for all MPC con-
trollers.
It indicates that an error was detected during execution of the last instruction on
that I/O channel.
Transmission Parity Error
A transmission parity error was detected during the execution of a special controller
instruction.
Inconsistent Command
Lock byte number specified is outside the lock byte area in the DSC.
Checksum Error
A checksum error on data was written to the MPC.
Byte Lockout
A Conditional Write Lock Byte instruction references a lock byte that is nonzero
(locked).
EDAC Parity Error
An MPC hardware error was detected in the EDAC generation.
Sector Size Error
A Seek instruction was received with incorrect size bits, or the data field length read
in the count field was not as specified in the previous Seek instruction.
Nonstandard Sector Size
An attempt was made to read on the disk a sector that was not a standard size for the
Series 6000.