Troubleshooting; Checkpoints - Samsung NX60 85 S Series User Manual

Hide thumbs Also See for NX60 85 S Series:
Table of Contents

Advertisement

Available languages

Available languages

Troubleshooting

If you encounter a problem with the range, check the tables starting below, and
then try the suggested actions.

Checkpoints

Gas safety
Problem
Possible cause
You smell gas.
The surface burner knob is
not in the OFF position and
the burner is not lit.
There is a gas leak.
44 English
Surface burner
All burners do not
light.
Action
Turn the burner knob to OFF.
Clear the room, building, or
area of all occupants.
Surface burners do
Immediately call your gas
not light.
supplier from a neighbor's
phone. Do not call from your
phone. It is electrical and
could cause a spark that could
ignite the gas. Follow the gas
Surface burner
supplier's instructions.
clicks during
If you cannot reach your
operation.
gas supplier, call the fire
department.
The burners do not
burn evenly.
Very large or
yellow surface
burner flames.
Problem
Cause
The power cord is
not plugged into the
electrical outlet.
A fuse in your home
may be blown or the
circuit breaker may have
tripped.
The gas supply is not
properly connected or
turned on.
The control knob is not
set properly.
The burner caps are not
in place.
The burner base is
misaligned.
The control knob has
been left in the Lite
position.
Surface burner
components and caps are
not assembled correctly
and level.
The surface burners are
dirty.
The wrong burner orifice
is installed.
Action
Make sure the electrical plug
is plugged into a live, properly
grounded outlet.
Replace the fuse or reset the
circuit breaker.
See the Installation
Instructions that came with
your range.
Push in the control knob and
turn it to the Lite position.
Clean the electrodes.
Put the burner cap on the
burner head.
Align the burner base.
After the burner lights, turn
the control knob to a desired
setting.
If the burner still clicks, contact
a service technician.
See page 38.
Clean the surface burner
components.
(See page 38.)
Check the burner orifice size.
Contact your installer if you
have the wrong orifice (LP
gas instead of natural gas or
natural gas instead of LP gas).

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Nx60 85 5 series

Table of Contents