Binks DXA-SC31B Service Manual
Binks DXA-SC31B Service Manual

Binks DXA-SC31B Service Manual

Active surge chamber

Advertisement

Quick Links

Service Manual
EN
DX 3:1
Active surge chamber
DXA-SC31B -
Stand alone unit
DXA-SC31P - Pump mounted unit (DX200-3S)
Patent Pending
1/16
77-3218-R1.2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DXA-SC31B and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Binks DXA-SC31B

  • Page 1 Service Manual DX 3:1 Active surge chamber DXA-SC31B - Stand alone unit DXA-SC31P - Pump mounted unit (DX200-3S) Patent Pending 1/16 77-3218-R1.2...
  • Page 2: Eu Declaration Of Conformity

    Product Description / Object of Declaration: Surge Chamber DXA-SC11P, DXA-SC11B, DXA-SC31P, DXA- SC31B This Product is designed for use with: Solvent and Water based materials Suitable for use in hazardous area: Zone 1 Protection Level: II 2 G c X IIB T4 Notified body details and role: Element Materials Technology (0891) Lodging of Technical file...
  • Page 3 In this part sheet, the words WARNING, CAUTION and NOTE are used to emphasize important safety information as follows: WARNING CAUTION NOTE Hazards or unsafe practices which could result in Hazards or unsafe practices which could result in Important installation, operation or maintenance severe personal injury, death or substantial minor personal injury, product or property information.
  • Page 4 Pump mounted 4.24 Kg Temperature range 0 - 40 °C [32-104 °F] Performance: Note: The surge chambers have been designed to work with Binks DX200-3 series pumps. They will operate with other makes of pump, but performance cannot be guaranteed. 4/16 77-3218-R1.2...
  • Page 5: Installation

    Installation Pump mounted model Stand alone model 5/16 77-3218-R1.2...
  • Page 6 Installation Connection to air supply Air supply can be fed from DXA-AC1-200-3 air control assy. Connection to air reservoir DXA-SCF Air reservoir shown mounted to wall bracket Air reservoir DXA-SC31P pump mounted unit shown 6/16 77-3218-R1.2...
  • Page 7 The surge chamber must be earthed at all times. A resistance <1Ω when measuring with an ohm- meter at the earth point Pump mounted unit DXA-SC31P is earthed via pump earth connection Earth connection, Binks Part No. 0114-011798 Paint section materials of construction Item...
  • Page 8: Spare Parts

    Bolts & Washers x8 DXK-254 Seal x4 DXK-253 Seal x5 GA-382-P Gauge DXK-252 Shaft & diaphragm assembly DXK-229 Stand alone inlet seal x4 (DXA-SC31B) DXK-230 Pump mounted inlet seal x4 (DXA-SC31P) DXK-229 Inlet/outlet seal x4 DXK-255 Spring DXK-257 Spool assembly 8/16...
  • Page 9 Spare Parts 9/16 77-3218-R1.2...
  • Page 10: Maintenance

    Maintenance Key - Maintenance symbols Order for dis-assembly (reverse for assembly) Grease (AGMD-010) refer to figure Spanner or socket size Torque required 10/16 77-3218-R1.2...
  • Page 11 Maintenance Figure 1 Note: It is not possible to separate the diaphragm and shaft 11/16 77-3218-R1.2...
  • Page 12 Accessories DXA-SCR1.0 Air Reservoir 1.0L Connection to ASC Item Part No. Description 0114-020027 ELBOW MSG-21 NIPPLE DVX-371 HOSE MSG-21 NIPPLE 192815 ELBOW 170250 HOSE DVX-268 NIPPLE DVX-333 1.0L RESERVOIR 12/16 77-3218-R1.2...
  • Page 13 Accessories DXA-AC1-200-SC Item Part No. Description GA-382-P Gauge MPV-10 QD stem 1\4" male DVX-267 Air Inlet Adaptor DXA-SCF Item Part No. Description DVX-268 Pushlock Connector Ø6 170250 Nylon Hose 13/16 77-3218-R1.2...
  • Page 14: Maintenance Schedule

    Maintenance schedule Typical period Recommended operation - Check for fluid or air leaks Monthly - Check for excessive fluid pressure pulsation 6 Months - Inspect surge chamber for correct operation - Check for constant exhausting & replace seals as required 12 Months - Check condition of hoses &...
  • Page 15: Fault Finding

    Fault finding Symptom Possible Cause Remedy Worn seals Replace seals Pump running to slow Increase cycle rate of pump ASC hunts to find correct pressure Excessive pump pulsation Improve pump performance Diaphragm damaged Replace diaphragm assembly Worn seals Replace seals Pulsation not Ensure air supply is connected reduced...
  • Page 16: Warranty Policy

    WARRANTY POLICY Binks products are covered by Carlisle Fluid Technologies five year materials and workmanship limited warranty. The use of any parts or accessories, from a source other than Carlisle Fluid Technologies, will void all warranties. For specific warranty information please contact the closest Carlisle Fluid Technologies location listed below.