Switches
Type
This determines whether the switch sends a MIDI CC message, Program Change
message (Program Chn), or Program Bank message.
When Type is set to CC, this is the MIDI CC number that the switch controls. The
CC#
available range is 0–127.
Program
When Type is set to Program Chn or Program Bank, this is the Program number that
the switch sends.
This is the MIDI channel over which the switch will send its MIDI message when you
MIDI Channel
press it. You can select the Common Channel (Common:##) or any one of Channels
A1–16 or B1–16.
Mode
When Type is set to CC, this determines whether the switch's operation is Toggle or
Momentary:
Invert
When Type is set to CC and Mode is set to Momentary, this determines whether the
switch's polarity is normal (Off) or inverted (On).
MSB / LSB
When Type is set to Program Bank, these determine the Most Significant Bit (MSB)
and Least Significant Bit (LSB) messages. The available range is 0–127.
Toggle: Each time you press the switch, it will turn on or off and remain in that
state until you press it again.
Momentary: The switch will be on for as long as you are holding it down. It will
turn off when you release it. This operation will be reversed if Invert is set to On.